Literature DB >> 19479295

Variation of airborne bacteria and fungi at Emperor Qin's Terra-Cotta Museum, Xi'an, China, during the "Oct. 1" gold week period of 2006.

Yi-Ping Chen1, Ying Cui, Jun-Gang Dong.   

Abstract

BACKGROUND, AIM, AND SCOPE: To stimulate the national economy, a so-called "gold week" comprising May Day and National Day has been put in force by the government, and the first golden-week holiday began on October 1, 1999. Statistical data show that about 15,000 visitors were received each day by Emperor Qin's Terra-Cotta Museum during just such a gold week period. To evaluate the effects of tourism on indoor air, airborne samples were collected by the sedimentation plate method for 5 min during the "Oct. 1" gold week period of 2006, and both composition and changes of airborne bacteria and fungi in indoor/outdoor air in the museums were investigated.
MATERIALS AND METHODS: Airborne microbes were simultaneously collected by means of gravitational sedimentation on open Petri dishes. Three parallel samples were collected at the same time each day, and samples were subsequently incubated in the lab. Microbiology media were prepared before each experiment by a professional laboratory. Concentrations were calculated and presented as average data of colony-forming units per cubic meter of air (CFU/m(3)).
RESULTS: The results show that (1) 13 bacterial genera and eight genera of fungi were identified from indoor and outdoor air at Emperor Qin's Terra-Cotta Museum during "Oct. 1" gold week in 2006. The bacterial groups occupied 61%, the fungi groups occupied 36%, and others occupied 3% of the total number of isolated microorganism genera. (2) As for the comparison of indoor and outdoor samples, the average concentrations of fungi were higher during the afternoon (13:00) than for the morning (09:00). The average concentrations of bacteria in indoor air were higher during the afternoon (13:00) than for the morning (9:00), and in outdoor air, they were lower during the afternoon (13:00) than for the morning (9:00). (3) The average concentrations of five dominant groups of bacteria and three dominant groups of fungi were higher during the afternoon (13:00) than for the morning (9:00) in the indoor air, but the average concentrations of fungi were higher and those of bacteria were lower during the afternoon than for the morning, for outdoor air. (4) As for the comparison of indoor samples, the bacterial daily concentrations and fungal daily concentrations were higher during the afternoon (13:00) than those for the mornings (9:00) over the 10 days. For the comparison of outdoor samples, the bacterial concentration was lower, and the fungal concentrations were higher during the afternoon (13:00) than those for the morning (9:00) over the 10 days. DISCUSSION: The results also show that the numbers of airborne bacteria and fungi had a daily character in indoor air and were higher in the afternoon. The airborne microbe concentrations were found to be similar to residential indoor values from other reports; the indoor museum maximum of microbial concentrations was 90 CFU/m(3) and did not exceed the Chinese indoor bioaerosol guideline. However, microorganisms may fall on the surface of display items as a result of particle sedimentation and would, as such, be capable of degrading objects by way of their secretions, e.g., enzymes and organic acids. Therefore, the right steps should be taken to prevent any deterioration in the quality of displayed artifacts.
CONCLUSIONS: The results show that museum air was affected by human activity; therefore, it is imperative that the number of visitors be strictly limited and that windows be opened regularly to avoid air pollution. RECOMMENDATIONS AND PERSPECTIVES: The data provide a significant scientific basis for indoor air quality control and museum scientific management. It is recommended that the number of visitors be strictly limited.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19479295     DOI: 10.1007/s11356-009-0161-1

Source DB:  PubMed          Journal:  Environ Sci Pollut Res Int        ISSN: 0944-1344            Impact factor:   4.223


  16 in total

1.  The indoor environment of a modern museum building, the Sainsbury Centre for Visual Arts, Norwich, UK.

Authors:  P Brimblecombe; N Blades; D Camuffo; G Sturaro; A Valentino; K Gysels; R Van Grieken; H J Busse; O Kim; U Ulrych; M Wieser
Journal:  Indoor Air       Date:  1999-09       Impact factor: 5.770

2.  Comparisons of seasonal fungal prevalence in indoor and outdoor air and in house dusts of dwellings in one Northeast American county.

Authors:  P Ren; T M Jankun; B P Leaderer
Journal:  J Expo Anal Environ Epidemiol       Date:  1999 Nov-Dec

3.  The relation between fungal propagules in indoor air and home characteristics.

Authors:  P Ren; T M Jankun; K Belanger; M B Bracken; B P Leaderer
Journal:  Allergy       Date:  2001-05       Impact factor: 13.146

4.  Comparison of the collecting efficiency of microbiological air samplers.

Authors:  H Shintani; E Taniai; A Miki; S Kurosu; F Hayashi
Journal:  J Hosp Infect       Date:  2004-01       Impact factor: 3.926

5.  Production of bacterial aerosols in a rendering plant process.

Authors:  J C SPENDLOVE
Journal:  Public Health Rep       Date:  1957-02       Impact factor: 2.792

Review 6.  Clinical manifestations of pulmonary Aspergillus infections.

Authors:  F Beaumont
Journal:  Mycoses       Date:  1988       Impact factor: 4.377

7.  Coliform aerosols emitted by sewage treatment plants.

Authors:  A P Adams; J C Spendlove
Journal:  Science       Date:  1970-09-18       Impact factor: 47.728

8.  Viable microorganisms in an urban atmosphere.

Authors:  T J Wright; V W Greene; H J Paulus
Journal:  J Air Pollut Control Assoc       Date:  1969-05

9.  Extrinsic allergic alveolitis after exposure to the yeast Rhodotorula rubra.

Authors:  H C Siersted; S Gravesen
Journal:  Allergy       Date:  1993-05       Impact factor: 13.146

10.  Respiratory health effects of home dampness and molds among Canadian children.

Authors:  R E Dales; H Zwanenburg; R Burnett; C A Franklin
Journal:  Am J Epidemiol       Date:  1991-07-15       Impact factor: 4.897

View more
  8 in total

1.  Cultural heritage and its environment: an issue of interest for Environmental Science and Pollution Research.

Authors:  Michel Sablier; Philippe Garrigues
Journal:  Environ Sci Pollut Res Int       Date:  2014-01-28       Impact factor: 4.223

2.  Concentrations and identification of culturable airborne fungi in underground stations of the Seoul metro.

Authors:  Sung Ho Hwang; Soojin Jang; Wha Me Park; Jae Bum Park
Journal:  Environ Sci Pollut Res Int       Date:  2016-07-29       Impact factor: 4.223

3.  Volatile organic compounds and bioaerosols in the vicinity of a municipal waste organic fraction treatment plant. Human health risks.

Authors:  Lolita Vilavert; Martí Nadal; María J Figueras; José L Domingo
Journal:  Environ Sci Pollut Res Int       Date:  2011-06-18       Impact factor: 4.223

4.  Detection of human-induced environmental disturbances in a show cave.

Authors:  Angel Fernandez-Cortes; Soledad Cuezva; Sergio Sanchez-Moral; Juan Carlos Cañaveras; Estefania Porca; Valme Jurado; Pedro Maria Martin-Sanchez; Cesareo Saiz-Jimenez
Journal:  Environ Sci Pollut Res Int       Date:  2011-05-07       Impact factor: 4.223

5.  Environmental Factors Shaping the Diversity and Spatial-Temporal Distribution of Indoor and Outdoor Culturable Airborne Fungal Communities in Tianjin University Campus, Tianjin, China.

Authors:  Chaonan Yuan; Xiao Wang; Lorenzo Pecoraro
Journal:  Front Microbiol       Date:  2022-06-14       Impact factor: 6.064

6.  Assessment of fungal bioaerosols and particulate matter characteristics in indoor and outdoor air of veterinary clinics.

Authors:  Shamim Mosalaei; Hoda Amiri; Ata Rafiee; Alireza Abbasi; Abbas Norouzian Baghani; Mohammad Hoseini
Journal:  J Environ Health Sci Eng       Date:  2021-08-28

7.  Analysis of culturable airborne fungi in outdoor environments in Tianjin, China.

Authors:  Yumna Nageen; Michael Dare Asemoloye; Sergei Põlme; Xiao Wang; Shihan Xu; Pramod W Ramteke; Lorenzo Pecoraro
Journal:  BMC Microbiol       Date:  2021-05-02       Impact factor: 4.465

8.  Analysis of variation in total airborne bacteria concentration to assess the performance of biological safety cabinets in microbial laboratories.

Authors:  Sung Ho Hwang; Hyun Hee Park; Chung Sik Yoon
Journal:  Saf Health Work       Date:  2014-01-24
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.