Literature DB >> 19479005

Self-focused ZnO transducers for ultrasonic biomicroscopy.

J M Cannata, J A Williams, Q F Zhou, L Sun, K K Shung, H Yu, E S Kim.   

Abstract

A simple fabrication technique was developed to produce high frequency (100 MHz) self-focused single element transducers with sputtered zinc oxide (ZnO) crystal films. This technique requires the sputtering of a ZnO film directly onto a curved backing substrate. Transducers were fabricated by sputtering an 18 mum thick ZnO layer on 2 mm diameter aluminum rods with ends shaped and polished to produce a 2 mm focus or f-number equal to one. The aluminum rod served a dual purpose as the backing layer and positive electrode for the resultant transducers. A 4 mum Parylene matching layer was deposited on the transducers after housing and interconnect. This matching layer was used to protect the substrate and condition the transfer of acoustic energy between the ZnO film and the load medium. The pulse-echo response for a representative transducer was centered at 101 MHz with a -6 dB bandwidth of 49%. The measured two way insertion loss was 44 dB. A tungsten wire phantom and an adult zebrafish eye were imaged to show the capability of these transducers.

Entities:  

Year:  2008        PMID: 19479005      PMCID: PMC2685215          DOI: 10.1063/1.2907716

Source DB:  PubMed          Journal:  J Appl Phys        ISSN: 0021-8979            Impact factor:   2.546


  3 in total

1.  The design of protection circuitry for high-frequency ultrasound imaging systems.

Authors:  G R Lockwood; J W Hunt; F S Foster
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

2.  A 120-MHz ultrasound probe for tissue imaging.

Authors:  K Yokosawa; R Shinomura; S Sano; Y Ito; S Ishikawa; Y Sato
Journal:  Ultrason Imaging       Date:  1996-10       Impact factor: 1.578

3.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

Authors:  Jonathan M Cannata; Timothy A Ritter; Wo-Hsing Chen; Ronald H Silverman; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

  3 in total
  2 in total

1.  80-MHz intravascular ultrasound transducer using PMN-PT free-standing film.

Authors:  Xiang Li; Wei Wu; Youngsoo Chung; Wan Y Shih; Wei-Heng Shih; Qifa Zhou; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-11       Impact factor: 2.725

2.  Design, Fabrication, and Evaluation of Multifocal Point Transducer for High-Frequency Ultrasound Applications.

Authors:  Thanh Phuoc Nguyen; Nguyen Thanh Phong Truong; Nhat Quang Bui; Van Tu Nguyen; Giang Hoang; Jaeyeop Choi; Thi Tuong Vy Phan; Van Hiep Pham; Byung-Gak Kim; Junghwan Oh
Journal:  Sensors (Basel)       Date:  2019-02-01       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.