2D dosimetry in a proton beam with a scintillating GEM detector.

E Seravalli1, M R de Boer, F Geurink, J Huizenga, R Kreuger, J M Schippers, C W E van Eijk.   

Abstract

A two-dimensional position-sensitive dosimetry system based on a scintillating gas detector is being developed for pre-treatment verification of dose distributions in particle therapy. The dosimetry system consists of a chamber filled with an Ar/CF(4) scintillating gas mixture, inside which two gas electron multiplier (GEM) structures are mounted (Seravalli et al 2008b Med. Phys. Biol. 53 4651-65). Photons emitted by the excited Ar/CF(4) gas molecules during the gas multiplication in the GEM holes are detected by a mirror-lens-CCD camera system. The intensity distribution of the measured light spot is proportional to the 2D dose distribution. In this work, we report on the characterization of the scintillating GEM detector in terms of those properties that are of particular importance in relative dose measurements, e.g. response reproducibility, dose dependence, dose rate dependence, spatial and time response, field size dependence, response uniformity. The experiments were performed in a 150 MeV proton beam. We found that the detector response is very stable for measurements performed in succession (sigma = 0.6%) and its response reproducibility over 2 days is about 5%. The detector response was found to be linear with the dose in the range 0.05-19 Gy. No dose rate effects were observed between 1 and 16 Gy min(-1) at the shallow depth of a water phantom and 2 and 38 Gy min(-1) at the Bragg peak depth. No field size effects were observed in the range 120-3850 mm(2). A signal rise and fall time of 2 micros was recorded and a spatial response of <or=1 mm was measured.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19478373     DOI: 10.1088/0031-9155/54/12/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Dose Imaging Detectors for Radiotherapy Based on Gas Electron Multipliers.

Authors:  A V Klyachko; D L Friesel; C Kline; J Liechty; D F Nichiporov; K A Solberg
Journal:  Nucl Instrum Methods Phys Res A       Date:  2011-02-01       Impact factor: 1.455

2.  A GEMPix-based integrated system for measurements of 3D dose distributions in water for carbon ion scanning beam radiotherapy.

Authors:  Johannes Leidner; Mario Ciocca; Andrea Mairani; Fabrizio Murtas; Marco Silari
Journal:  Med Phys       Date:  2020-03-21       Impact factor: 4.071

3.  Development of a time-resolved mirrorless scintillation detector.

Authors:  Wonjoong Cheon; Hyunuk Jung; Moonhee Lee; Jinhyeop Lee; Sung Jin Kim; Sungkoo Cho; Youngyih Han
Journal:  PLoS One       Date:  2021-02-12       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.