Literature DB >> 19475045

Liquid phantom for investigating light propagation through layered diffusive media.

S Del Bianco, F Martelli, F Cignini, G Zaccanti, A Pifferi, A Torricelli, A Bassi, P Taroni, R Cubeddu.   

Abstract

A liquid phantom for investigating light propagation through layered diffusive media is described. The diffusive medium is an aqueous suspension of calibrated scatterers and absorbers. A thin membrane separates layers with different optical properties. Experiments showed that a material with scattering properties should be used for the membrane to avoid the perturbation due to the guided propagation that occurs through a transparent layer. Examples of measurements on a three-layered medium are reported both in the cw and in the time domain.

Year:  2004        PMID: 19475045     DOI: 10.1364/opex.12.002102

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  7 in total

1.  Multi-channel medical device for time domain functional near infrared spectroscopy based on wavelength space multiplexing.

Authors:  Rebecca Re; Davide Contini; Massimo Turola; Lorenzo Spinelli; Lucia Zucchelli; Matteo Caffini; Rinaldo Cubeddu; Alessandro Torricelli
Journal:  Biomed Opt Express       Date:  2013-09-24       Impact factor: 3.732

2.  Space-enhanced time-domain diffuse optics for determination of tissue optical properties in two-layered structures.

Authors:  Lin Yang; Heidrun Wabnitz; Thomas Gladytz; Aleh Sudakou; Rainer Macdonald; Dirk Grosenick
Journal:  Biomed Opt Express       Date:  2020-10-21       Impact factor: 3.732

3.  Depth sensitivity of frequency domain optical measurements in diffusive media.

Authors:  Tiziano Binzoni; Angelo Sassaroli; Alessandro Torricelli; Lorenzo Spinelli; Andrea Farina; Turgut Durduran; Stefano Cavalieri; Antonio Pifferi; Fabrizio Martelli
Journal:  Biomed Opt Express       Date:  2017-05-17       Impact factor: 3.732

4.  Modeling the performance characteristics of computed radiography (CR) systems.

Authors:  Srinivasan Vedantham; Andrew Karellas
Journal:  IEEE Trans Med Imaging       Date:  2010-03       Impact factor: 10.048

5.  Effect of dependent scattering on the optical properties of Intralipid tissue phantoms.

Authors:  Paola Di Ninni; Fabrizio Martelli; Giovanni Zaccanti
Journal:  Biomed Opt Express       Date:  2011-07-14       Impact factor: 3.732

6.  A Compact Multi-Distance DCS and Time Domain NIRS Hybrid System for Hemodynamic and Metabolic Measurements.

Authors:  Caterina Amendola; Michele Lacerenza; Mauro Buttafava; Alberto Tosi; Lorenzo Spinelli; Davide Contini; Alessandro Torricelli
Journal:  Sensors (Basel)       Date:  2021-01-28       Impact factor: 3.576

7.  Optical characterization of two-layered turbid media for non-invasive, absolute oximetry in cerebral and extracerebral tissue.

Authors:  Bertan Hallacoglu; Angelo Sassaroli; Sergio Fantini
Journal:  PLoS One       Date:  2013-05-21       Impact factor: 3.240