Literature DB >> 19468184

Loop-mediated isothermal amplification (LAMP) for the direct detection of human pulmonary infections with environmental (nontuberculosis) mycobacteria.

Bal Ram Adhikari1, Basu Dev Pandey, Prakash Ghimire, Bhawana Shrestha, Manoj Khadka, Tomoko Yoda, Yasuhiko Suzuki.   

Abstract

Most first-line anti-tuberculosis drugs have less in vitro activity against atypical mycobacteria. Loop-mediated isothermal amplification (LAMP) was used for the rapid diagnosis of mycobacterial species. The sensitivity of LAMP was 96.1% (49/51) in smear-positive and culture-positive sputum samples and 85.0% (17/20) in smear-negative and culture-positive samples. Of the 77 total LAMP-positive samples, 75 (97.4%) were identified as Mycobacterium tuberculosis and 2 (2.6%) as M. intracellulare. One of the M. intracellulare-infected cases was identified in a patient with suspected mycobacteriosis and another was found in a follow-up patient.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19468184

Source DB:  PubMed          Journal:  Jpn J Infect Dis        ISSN: 1344-6304            Impact factor:   1.362


  10 in total

1.  Loop-mediated isothermal amplification for rapid and reliable diagnosis of tuberculous meningitis.

Authors:  Khushboo J Nagdev; Rajpal S Kashyap; Manmohan M Parida; Rajkumar C Kapgate; Hemant J Purohit; Girdhar M Taori; Hatim F Daginawala
Journal:  J Clin Microbiol       Date:  2011-03-16       Impact factor: 5.948

2.  Evaluation of in-house loop-mediated isothermal amplification (LAMP) assay for rapid diagnosis of M. tuberculosis in pulmonary specimens.

Authors:  Sunil Sethi; Sunil Kumar Sethi; Sumeet Singh; Sunil Kumar Dhatwalia; Rakesh Yadav; Abhishek Mewara; Malkit Singh; Rupinder Tewari; Meera Sharma
Journal:  J Clin Lab Anal       Date:  2013-07       Impact factor: 2.352

3.  Rapid and sensitive detection of Citrus Bacterial Canker by loop-mediated isothermal amplification combined with simple visual evaluation methods.

Authors:  Luciano A Rigano; María R Marano; Atilio P Castagnaro; Alexandre Morais Do Amaral; Adrian A Vojnov
Journal:  BMC Microbiol       Date:  2010-06-18       Impact factor: 3.605

4.  Diagnostic accuracy of the PURE-LAMP test for pulmonary tuberculosis at the county-level laboratory in China.

Authors:  Xichao Ou; Qiang Li; Hui Xia; Yu Pang; Shengfen Wang; Bing Zhao; Yuanyuan Song; Yang Zhou; Yang Zheng; Zhijian Zhang; Zhiying Zhang; Junchen Li; Haiyan Dong; Jack Zhang; Kai Man Kam; Junying Chi; Shitong Huan; Daniel P Chin; Yanlin Zhao
Journal:  PLoS One       Date:  2014-05-01       Impact factor: 3.240

5.  The Sensitivity and Specificity of Loop-Mediated Isothermal Amplification (LAMP) Assay for Tuberculosis Diagnosis in Adults with Chronic Cough in Malawi.

Authors:  Marriott Nliwasa; Peter MacPherson; Palesa Chisala; Mercy Kamdolozi; McEwen Khundi; Kruger Kaswaswa; Mphatso Mwapasa; Chisomo Msefula; Hojoon Sohn; Clare Flach; Elizabeth L Corbett
Journal:  PLoS One       Date:  2016-05-12       Impact factor: 3.240

6.  Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis.

Authors:  Baye Gelaw; Yitayal Shiferaw; Marta Alemayehu; Abate Assefa Bashaw
Journal:  BMC Infect Dis       Date:  2017-01-17       Impact factor: 3.090

7.  rpoB Targeted Loop-Mediated Isothermal Amplification (LAMP) Assay for Consensus Detection of Mycobacteria Associated With Pulmonary Infections.

Authors:  Simon Grandjean Lapierre; Michel Drancourt
Journal:  Front Med (Lausanne)       Date:  2018-11-28

Review 8.  Detecting amplicons of loop-mediated isothermal amplification.

Authors:  Kazuya Shirato
Journal:  Microbiol Immunol       Date:  2019-08-13       Impact factor: 1.955

9.  Development and evaluation of an in-house single step loop-mediated isothermal amplification (SS-LAMP) assay for the detection of Mycobacterium tuberculosis complex in sputum samples from Moroccan patients.

Authors:  El Mehdi Bentaleb; Mohammed Abid; My Driss El Messaoudi; Brahim Lakssir; El Mostafa Ressami; Saaïd Amzazi; Hassan Sefrioui; Hassan Ait Benhassou
Journal:  BMC Infect Dis       Date:  2016-09-27       Impact factor: 3.090

10.  Development of fluorescent reverse transcription loop-mediated isothermal amplification (RT-LAMP) using quenching probes for the detection of the Middle East respiratory syndrome coronavirus.

Authors:  Kazuya Shirato; Shohei Semba; Sherif A El-Kafrawy; Ahmed M Hassan; Ahmed M Tolah; Ikuyo Takayama; Tsutomu Kageyama; Tsugunori Notomi; Wataru Kamitani; Shutoku Matsuyama; Esam Ibraheem Azhar
Journal:  J Virol Methods       Date:  2018-05-12       Impact factor: 2.014

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.