Lowering the dose of sirolimus, released from a nonpolymeric hydroxyapatite coated coronary stent, reduces signs of delayed healing.

Wim J van der Giessen1, Oana Sorop, Patrick W Serruys, Ilona Peters-Krabbendam, Heleen M M van Beusekom.   

Abstract

OBJECTIVES: The aim of this study was to compare efficacy of low- and high-dose sirolimus release (25, 40, or 100 microg) from hydroxyapatite (HAp) with Cypher (Cordis, Johnson & Johnson, Warren, New Jersey) (111 microg sirolimus) in porcine coronary arteries.
BACKGROUND: Polymer-based sirolimus-eluting stents such as Cypher interfere with vascular healing, probably due to the permanent presence of the polymer coating and the high sirolimus dose. The use of low-dose sirolimus and inert nonpolymeric but biodegradable coatings such as HAp might be more appropriate.
METHODS: Stents (n = 68) were implanted, guided by quantitative coronary angiography. All swine received clopidogrel and acetylsalicylic acid during 28 days follow-up. Safety of the coating in absence of drugs was studied by comparing HAp with and without a lipid-based release regulating layer (HApR) with bare-metal stents. Efficacy was studied by comparing the release of 25, 40, and 100 microg sirolimus with Cypher.
RESULTS: The safety study (without drug) revealed no differences in neointimal thickening in response to HAp and HApR with complete healing in all groups. Dose response analysis showed that neointimal thickening was similar in all groups regardless of sirolimus dose, with a normal appearance of the endothelium. There was, however, a dose-dependent increase in fibrinoid (p = 0.028), considered to be a marker of delayed healing. The Cypher stent induced the highest amount of fibrinoid.
CONCLUSIONS: Reducing the dose of sirolimus eluting from a biocompatible HAp coated stent reduces signs of delayed vascular healing, without affecting neointimal hyperplasia.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19463438     DOI: 10.1016/j.jcin.2008.12.012

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  15 in total

1.  Low-dose sirolimus-eluting hydroxyapatite coating on stents does not increase platelet activation and adhesion ex vivo.

Authors:  Carlos L Alviar; Armando Tellez; Michael Wang; Pamela Potts; Doug Smith; Manus Tsui; Wladyslaw Budzynski; Albert E Raizner; Neal S Kleiman; Eli I Lev; Juan F Granada; Greg L Kaluza
Journal:  J Thromb Thrombolysis       Date:  2012-07       Impact factor: 2.300

2.  Accelerated endothelialization with a polymer-free sirolimus-eluting antibody-coated stent.

Authors:  Zhanjiang Yu; Huagang Zhu; Shuzheng Lü; Xiaoda Yang
Journal:  J Mater Sci Mater Med       Date:  2013-08-23       Impact factor: 3.896

3.  Investigating the feasibility of using a grit blasting process to coat nitinol stents with hydroxyapatite.

Authors:  F Keady; B P Murphy
Journal:  J Mater Sci Mater Med       Date:  2012-10-07       Impact factor: 3.896

4.  Real-time volumetric lipid imaging in vivo by intravascular photoacoustics at 20 frames per second.

Authors:  Min Wu; Geert Springeling; Matija Lovrak; Frits Mastik; Sophinese Iskander-Rizk; Tianshi Wang; Heleen M M van Beusekom; A F W van der Steen; Gijs Van Soest
Journal:  Biomed Opt Express       Date:  2017-01-18       Impact factor: 3.732

5.  Delivery of paclitaxel from cobalt-chromium alloy surfaces without polymeric carriers.

Authors:  Gopinath Mani; Celia E Macias; Marc D Feldman; Denes Marton; Sunho Oh; C Mauli Agrawal
Journal:  Biomaterials       Date:  2010-04-15       Impact factor: 12.479

6.  [New developments in drug-eluting stents].

Authors:  M Kollum; C Bode
Journal:  Herz       Date:  2011-05       Impact factor: 1.443

Review 7.  Targeted Delivery of Bioactive Molecules for Vascular Intervention and Tissue Engineering.

Authors:  Hannah A Strobel; Elisabet I Qendro; Eben Alsberg; Marsha W Rolle
Journal:  Front Pharmacol       Date:  2018-11-21       Impact factor: 5.810

8.  Next generation drug-eluting stents: focus on bioabsorbable platforms and polymers.

Authors:  Brendan Doyle; David R Holmes
Journal:  Med Devices (Auckl)       Date:  2009-11-10

9.  High-Resolution Imaging of Interaction Between Thrombus and Stent-Retriever in Patients With Acute Ischemic Stroke.

Authors:  Anouchska S A Autar; Hajo M Hund; Sharad A Ramlal; Daniël Hansen; Geert J Lycklama À Nijeholt; Bart J Emmer; Moniek P M de Maat; Diederik W J Dippel; Aad van der Lugt; Adriaan C G M van Es; Heleen M M van Beusekom
Journal:  J Am Heart Assoc       Date:  2018-06-22       Impact factor: 5.501

10.  Sirolimus-Eluting Electrospun-Produced Matrices as Coatings for Vascular Stents: Dependence of Drug Release on Matrix Structure and Composition of the External Environment.

Authors:  Zhanna K Nazarkina; Boris P Chelobanov; Vera S Chernonosova; Irina V Romanova; Andrey A Karpenko; Pavel P Laktionov
Journal:  Materials (Basel)       Date:  2020-06-12       Impact factor: 3.623

View more