OBJECTIVES: In this retrospective study, we examined the incidence of post-procedural conduction abnormalities and the need for pacing in patients undergoing percutaneous implantation of the aortic valve. BACKGROUND: Safety and feasibility studies have suggested anecdotally the occurrence of conduction abnormalities and requirements for pacing after percutaneous implantation of the aortic valve. METHODS: We examined the standard 12-lead electrocardiograms (ECGs) of 40 consecutive patients in whom a CoreValve Revalving System (CoreValve, Paris, France) was implanted between November 2005 and March 2008. We examined the 12-lead ECG before treatment, after treatment, and at 1-month follow-up. We documented the requirements for temporary or permanent pacemaking. RESULTS: The mean age of patients was 82 +/- 7 years. Post-procedural mortality at 72 h was 0%. There was a significant increase in the frequency of left bundle branch block (LBBB) after percutaneous aortic valve replacement (15% before treatment vs. 55% after treatment, p = 0.001). Although the incidence of LBBB had decreased after follow-up of 1 month, it did not reach statistical significance, with the proportion decreasing from 55% to 48% (p = 0.63). The only 2 patients with pre-treatment right bundle branch block became dependent on temporary pacing immediately after valve implantation and subsequently needed permanent pacing. A temporary and permanent pacemaker was required in 20% and 18% of patients, respectively. CONCLUSIONS: In this study, there was a significant increase in the frequency of LBBB after percutaneous insertion of the aortic valvar prosthesis. Patients with pre-existing right bundle branch block may be at risk for the development of complete heart block and subsequent need for pacing.
OBJECTIVES: In this retrospective study, we examined the incidence of post-procedural conduction abnormalities and the need for pacing in patients undergoing percutaneous implantation of the aortic valve. BACKGROUND: Safety and feasibility studies have suggested anecdotally the occurrence of conduction abnormalities and requirements for pacing after percutaneous implantation of the aortic valve. METHODS: We examined the standard 12-lead electrocardiograms (ECGs) of 40 consecutive patients in whom a CoreValve Revalving System (CoreValve, Paris, France) was implanted between November 2005 and March 2008. We examined the 12-lead ECG before treatment, after treatment, and at 1-month follow-up. We documented the requirements for temporary or permanent pacemaking. RESULTS: The mean age of patients was 82 +/- 7 years. Post-procedural mortality at 72 h was 0%. There was a significant increase in the frequency of left bundle branch block (LBBB) after percutaneous aortic valve replacement (15% before treatment vs. 55% after treatment, p = 0.001). Although the incidence of LBBB had decreased after follow-up of 1 month, it did not reach statistical significance, with the proportion decreasing from 55% to 48% (p = 0.63). The only 2 patients with pre-treatment right bundle branch block became dependent on temporary pacing immediately after valve implantation and subsequently needed permanent pacing. A temporary and permanent pacemaker was required in 20% and 18% of patients, respectively. CONCLUSIONS: In this study, there was a significant increase in the frequency of LBBB after percutaneous insertion of the aortic valvar prosthesis. Patients with pre-existing right bundle branch block may be at risk for the development of complete heart block and subsequent need for pacing.
Authors: Shikhar Agarwal; E Murat Tuzcu; William Stewart; Navkaranbir Singh Bajaj; Lars G Svensson; Samir R Kapadia Journal: Indian Heart J Date: 2013-07-10
Authors: Marcel Weber; Eva Brüggemann; Robert Schueler; Diana Momcilovic; Jan-Malte Sinning; Alexander Ghanem; Nikos Werner; Eberhard Grube; Wolfgang Schiller; Fritz Mellert; Armin Welz; Georg Nickenig; Christoph Hammerstingl Journal: Clin Res Cardiol Date: 2015-05-13 Impact factor: 5.460
Authors: Jochen Reinöhl; Constantin von Zur Mühlen; Martin Moser; Stefan Sorg; Christoph Bode; Manfred Zehender Journal: J Thromb Thrombolysis Date: 2013-05 Impact factor: 2.300
Authors: Robert M A van der Boon; Patrick Houthuizen; Rutger-Jan Nuis; Nicolas M van Mieghem; Frits Prinzen; Peter P T de Jaegere Journal: Curr Cardiol Rep Date: 2014-01 Impact factor: 2.931