Literature DB >> 19454994

A study on the structural properties of the lumbar endplate: histological structure, the effect of bone density, and spinal level.

Yang Hou1, Zhoujing Luo.   

Abstract

STUDY
DESIGN: Histologic experiments and biomechanical tests were performed in human cadaveric lumbar spine models.
OBJECTIVE: To determine (1) the anatomic structures of lumbar endplates, (2) the relationship between bone mineral density (BMD) and biomechanical properties of lumbar endplates, and (3) the influence of spinal level on the failure loads of lumbar endplates. SUMMARY OF BACKGROUND DATA: Previous works have shown that the posterolateral corners of the lumbar endplates are stronger than the anterior and central regions. Information on the microstructures of lumbar endplates and the effects of both BMD and spinal level on biomechanical properties of lumbar endplates would be valuable for spine surgeons and implant designers to avoid subsidence.
METHODS: Twenty fresh human cadaver lumbar vertebrae specimens were collected for HE staining and the sections through the specimens were examined under light microscope. The areas of the pore structures in the lumbar endplates were measured and analyzed by statistical methods. Sixty-five cadaver lumbar vertebrae were evaluated with dual energy radiograph absorptiometry and according to their BMD, all vertebrae were divided into 3 groups. Indentation tests were performed at 27 standardized test sites in endplates of these vertebrae using a 1.5-mm-diameter, hemispherical indenter with a rate of 12 mm/min. The failure load at each test site was determined using the load-displacement curve. Spearman analysis was used to evaluate the correlation between BMD and failure loads of lumbar endplates. Factorial analysis of variance was performed to reveal the effects of both BMD and spinal level on failure load distribution on the lumbar endplates.
RESULTS: (1) The peripheral regions were thicker than the central regions of lumbar endplates. The central regions were porous, as the fused trabeculae and peripheral regions had fewer and smaller pore structures. (2) The tests showed that there were significant differences in failure load between 3 groups (P < 0.01). BMD was positively correlated with the failure load of the lumbar endplate. (3) The strongest position of the lumbar endplate was the posterolateral region closest to the pedicles and the failure loads tended to increase from anterior to posterior regions of the lumbar endplates. (4) The failure load distribution did not change with the BMD decrease. (5) The differences of the failure loads between the lumbar segments were significant (P < 0.05). The failure loads of the lumbar endplates showed an increasing tendency from L1-L5 segments.
CONCLUSION: The differences in the anatomic structures of different regions are the histologic foundation of biomechanical properties of lumbar endplates. It is necessary that BMD should be measured before operation and implants should be placed in posterior-lateral regions of lumbar endplates so that subsidence syndrome can be reduced as much as possible. In addition, the fact that the endplates of the upper lumbar segments with the lower strength have higher risk of subsidence should be concerned about by spine surgeons and implant designers.

Entities:  

Mesh:

Year:  2009        PMID: 19454994     DOI: 10.1097/BRS.0b013e3181a2ea0a

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  28 in total

1.  In silico evaluation of a new composite disc substitute with a L3-L5 lumbar spine finite element model.

Authors:  Jérôme Noailly; Luigi Ambrosio; K Elizabeth Tanner; Josep A Planell; Damien Lacroix
Journal:  Eur Spine J       Date:  2011-03-05       Impact factor: 3.134

Review 2.  [Intervertebral cages from a biomechanical point of view].

Authors:  W Schmoelz; A Keiler
Journal:  Orthopade       Date:  2015-02       Impact factor: 1.087

Review 3.  Complications on minimally invasive oblique lumbar interbody fusion at L2-L5 levels: a review of the literature and surgical strategies.

Authors:  Javier Quillo-Olvera; Guang-Xun Lin; Hyun-Jin Jo; Jin-Sung Kim
Journal:  Ann Transl Med       Date:  2018-03

4.  Thoracolumbar kyphosis is associated with compressive vertebral fracture in postmenopausal women.

Authors:  Y Wei; W Tian; G L Zhang; Y W Lv; G Y Cui
Journal:  Osteoporos Int       Date:  2017-03-01       Impact factor: 4.507

5.  [Experiences with PMMA cement as a stand-alone intervertebral spacer. Percutaneous cement discoplasty in the case of vacuum phenomenon within lumbar intervertebral discs].

Authors:  P P Varga; G Jakab; I B Bors; A Lazary; Z Szövérfi
Journal:  Orthopade       Date:  2015-02       Impact factor: 1.087

6.  Vertebral body fracture following stand-alone lateral lumbar interbody fusion (LLIF): report of two events out of 712 levels.

Authors:  Zachary J Tempel; Gurpreet S Gandhoke; Bryan D Bolinger; David O Okonkwo; Adam S Kanter
Journal:  Eur Spine J       Date:  2015-03-17       Impact factor: 3.134

7.  [Advances in research on Cage subsidence following lumbar interbody fusion].

Authors:  Long Zhao; Jiancheng Zeng; Tianhang Xie; Xingxiao Pu; Yufei Lu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-08-15

8.  The Effect of Alendronate on Subsidence After Lateral Transpsoas Interbody Fusion: A Preliminary Report.

Authors:  Rahul G Samtani; James T Bernatz; Rachel Harrison; Siddharth Roy; Sachin Gupta; Joseph R O'Brien
Journal:  Int J Spine Surg       Date:  2019-06-30

9.  Novel Titanium Cages for Minimally Invasive Lateral Lumbar Interbody Fusion: First Assessment of Subsidence.

Authors:  Paul R Krafft; Brooks Osburn; Andrew C Vivas; Gautam Rao; Puya Alikhani
Journal:  Spine Surg Relat Res       Date:  2019-12-20

10.  Acute lumbar burst fracture treated by minimally invasive lateral corpectomy.

Authors:  Rodrigo Amaral; Luis Marchi; Leonardo Oliveira; Thiago Coutinho; Luiz Pimenta
Journal:  Case Rep Orthop       Date:  2013-03-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.