Literature DB >> 1945334

The effect of distraction upon bone, muscle, and periosteum.

N Yasui1, H Kojimoto, H Shimizu, Y Shimomura.   

Abstract

Bone lengthening was achieved on rabbit tibias by means of callus distraction (callotasis) using a dynamic external fixator. The periosteum and the muscle fascia were labeled with metal markers; changes in position of these markers during slow progressive distraction were monitored by soft radiography. During the waiting period before commencing distraction, the periosteal markers around the osteotomy site were elevated from the bone surface by newly formed external callus. There was an apparent lag period until the periosteal reaction occurred after osteotomy. Subperiosteal callus was first formed in an uncalcified state and subsequently became calcified. As distraction began, longitudinal migration of the periosteal markers was observed. It appears that the periosteum slides over the bone cortex, mitigating local stretching of the muscle around osteotomy site. The elongation of muscle occurs throughout the muscle substance and not simply at the site of osteotomy.

Entities:  

Mesh:

Year:  1991        PMID: 1945334

Source DB:  PubMed          Journal:  Orthop Clin North Am        ISSN: 0030-5898            Impact factor:   2.472


  7 in total

1.  Insufficient bone regenerate after intramedullary femoral lengthening: risk factors and classification system.

Authors:  Mohamed Kenawey; Christian Krettek; Emmanouil Liodakis; Rupert Meller; Stefan Hankemeier
Journal:  Clin Orthop Relat Res       Date:  2010-04-02       Impact factor: 4.176

2.  The effect of latency on bone lengthening force and bone mineralization: an investigation using strain gauge mounted on internal distractor device.

Authors:  Sekou Singare; Dichen Li; Yaxiong Liu; Zhongying Wu; Jue Wang
Journal:  Biomed Eng Online       Date:  2006-03-09       Impact factor: 2.819

3.  Endosseous alveolar distractor (LEAD™) in the management of residual alveolar ridge resorption.

Authors:  S Sudeep; G K Thapliyal; P Suresh Menon; Ramen Sinha
Journal:  J Maxillofac Oral Surg       Date:  2010-04-24

4.  Device for lengthening of a musculotendinous unit by direct continuous traction in the sheep.

Authors:  Matthias A Zumstein; Eric Frey; Brigitte von Rechenberg; Robert Frigg; Christian Gerber; Dominik C Meyer
Journal:  BMC Vet Res       Date:  2012-05-02       Impact factor: 2.741

5.  Impact of leg lengthening on viscoelastic properties of the deep fascia.

Authors:  Hai-Qiang Wang; Yi-Yong Wei; Zi-Xiang Wu; Zhuo-Jing Luo
Journal:  BMC Musculoskelet Disord       Date:  2009-08-21       Impact factor: 2.362

6.  Distraction osteogenesis in dog with a tooth-borne device: Histological and histomorphometric analysis.

Authors:  Francisco Vale; Inês Francisco; João Cavaleiro; Francisco Caramelo; Adriana Guimarães; João Brochado
Journal:  J Clin Exp Dent       Date:  2020-01-01

7.  The effect on the extracellular matrix of the deep fascia in response to leg lengthening.

Authors:  Hai-Qiang Wang; Xin-Kui Li; Zi-Xiang Wu; Yi-Yong Wei; Zhuo-Jing Luo
Journal:  BMC Musculoskelet Disord       Date:  2008-07-09       Impact factor: 2.362

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.