Literature DB >> 19447702

Effect of domain shape modeling and measurement errors on the 2-D D-bar method for EIT.

Ethan K Murphy1, Jennifer L Mueller.   

Abstract

The D-bar algorithm based on Nachman's 2-D global uniqueness proof for the inverse conductivity problem (Nachman, 1996) is implemented on a chest-shaped domain. The scattering transform is computed on this chest-shaped domain using trigonometric and adjacent current patterns and the complete electrode model for the forward problem is computed with the finite element method in order to obtain simulated voltage measurements. The robustness and effectiveness of the method is demonstrated on a simulated chest with errors in input currents, output voltages, electrode placement, and domain modeling.

Mesh:

Year:  2009        PMID: 19447702     DOI: 10.1109/TMI.2009.2021611

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  9 in total

1.  Calderón's method on an elliptical domain.

Authors:  P A Muller; D Isaacson; J C Newell; G J Saulnier
Journal:  Physiol Meas       Date:  2013-05-29       Impact factor: 2.833

2.  A Real-time D-bar Algorithm for 2-D Electrical Impedance Tomography Data.

Authors:  Melody Dodd; Jennifer L Mueller
Journal:  Inverse Probl Imaging (Springfield)       Date:  2014-11-01       Impact factor: 1.639

3.  Beltrami-net: domain-independent deep D-bar learning for absolute imaging with electrical impedance tomography (a-EIT).

Authors:  S J Hamilton; A Hänninen; A Hauptmann; V Kolehmainen
Journal:  Physiol Meas       Date:  2019-07-23       Impact factor: 2.833

4.  Incorporating a Spatial Prior into Nonlinear D-Bar EIT Imaging for Complex Admittivities.

Authors:  Sarah J Hamilton; J L Mueller; M Alsaker
Journal:  IEEE Trans Med Imaging       Date:  2016-09-26       Impact factor: 10.048

5.  Direct 2-D reconstructions of conductivity and permittivity from EIT data on a human chest.

Authors:  Claudia N L Herrera; Miguel F M Vallejo; Jennifer L Mueller; Raul G Lima
Journal:  IEEE Trans Med Imaging       Date:  2014-09-04       Impact factor: 10.048

6.  Precise two-dimensional D-bar reconstructions of human chest and phantom tank via sinc-convolution algorithm.

Authors:  Mahdi Abbasi; Ahmad-Reza Naghsh-Nilchi
Journal:  Biomed Eng Online       Date:  2012-06-20       Impact factor: 2.819

7.  Measurement-Based Domain Parameter Optimization in Electrical Impedance Tomography Imaging.

Authors:  Jan Dusek; Jan Mikulka
Journal:  Sensors (Basel)       Date:  2021-04-03       Impact factor: 3.576

8.  Complementary use of priors for pulmonary imaging with electrical impedance and ultrasound computed tomography.

Authors:  Melody Alsaker; Diego Armando Cardona Cárdenas; Sérgio Shiguemi Furuie; Jennifer L Mueller
Journal:  J Comput Appl Math       Date:  2021-04-20       Impact factor: 2.872

9.  Introduction of Sample Based Prior into the D-Bar Method Through a Schur Complement Property.

Authors:  Talles Batista Rattis Santos; Rafael Mikio Nakanishi; Jari P Kaipio; Jennifer L Mueller; Raul Gonzalez Lima
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 11.037

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.