Literature DB >> 19442948

Intraoperative fluorescence imaging system for on-site assessment of off-pump coronary artery bypass graft.

Katsuhisa Waseda1, Junya Ako, Takao Hasegawa, Yoshihisa Shimada, Fumiaki Ikeno, Toshihiro Ishikawa, Yoshitaka Demura, Kazuyoshi Hatada, Paul G Yock, Yasuhiro Honda, Peter J Fitzgerald, Masao Takahashi.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the intraoperative fluorescence imaging (IFI) system in the real-time assessment of graft patency during off-pump coronary artery bypass graft.
BACKGROUND: Intraoperative fluorescence imaging is an intraoperative angiography-like imaging modality using fluorescent indocyanine green excited with laser light. Recently, assessment of graft patency using the IFI system was introduced into clinical use. The feasibility and efficacy of IFI technology in off-pump coronary artery bypass graft has not been systematically compared with other conventional diagnostic modalities.
METHODS: Patients undergoing off-pump coronary artery bypass graft received IFI analysis, intraoperative transit time flowmetry, and postoperative X-ray angiography. In off-line IFI analysis, the graft washout was classified based on the number of heartbeats required for indocyanine green washout: fast washout (<or=15 beats) and slow washout (>15 beats).
RESULTS: A total of 507 grafts in 137 patients received IFI analysis. Of all the IFI analyses, 379 (75%) grafts were visualized clearly up to the distal anastomosis. With regard to anastomosis location, anterior location was associated with a higher percentage of fully analyzable images (90%). More than 80% of images were analyzable, irrespective of graft type. Six grafts with acceptable transit time flowmetry results were diagnosed with graft failure by IFI, which required on-site graft revision. All revised grafts' patency was confirmed by post-operative X-ray angiography. Conversely, 21 grafts with unsatisfactory transit time flowmetry results demonstrated acceptable patency with IFI. Graft revision was considered unnecessary in these grafts, and 20 grafts (95%) were patent by post-operative X-ray angiography. Compared with slow washout, fast washout was associated with a higher preoperative ejection fraction, use of internal mammary artery grafts, and anterior anastomosis location.
CONCLUSIONS: The IFI system enables on-site assessment of graft patency, providing both morphologic and functional information. This technique may help reduce procedure-related, early graft failures in off-pump bypass patients.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19442948     DOI: 10.1016/j.jcmg.2008.12.028

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  13 in total

Review 1.  Image-guided surgery using invisible near-infrared light: fundamentals of clinical translation.

Authors:  Sylvain Gioux; Hak Soo Choi; John V Frangioni
Journal:  Mol Imaging       Date:  2010-10       Impact factor: 4.488

2.  Evaluation of intestinal perfusion by ICG fluorescence imaging in laparoscopic colorectal surgery with DST anastomosis.

Authors:  Kenji Kawada; Suguru Hasegawa; Toshiaki Wada; Ryo Takahashi; Shigeo Hisamori; Koya Hida; Yoshiharu Sakai
Journal:  Surg Endosc       Date:  2016-06-28       Impact factor: 4.584

Review 3.  Intraoperative graft assessment during coronary artery bypass surgery.

Authors:  Toshihiro Fukui
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-01-06

4.  The histopathological evaluation based on the indocyanine green fluorescence imaging of regional lymph node metastasis of splenic flexural colon cancer by near-infrared observation.

Authors:  Manabu Kakizoe; Jun Watanabe; Yusuke Suwa; Kazuya Nakagawa; Hirokazu Suwa; Mayumi Ozawa; Atsushi Ishibe; Hidenobu Masui; Kaoru Nagahori
Journal:  Int J Colorectal Dis       Date:  2020-11-19       Impact factor: 2.571

5.  ICG fluorescence imaging for quantitative evaluation of colonic perfusion in laparoscopic colorectal surgery.

Authors:  Toshiaki Wada; Kenji Kawada; Ryo Takahashi; Mami Yoshitomi; Koya Hida; Suguru Hasegawa; Yoshiharu Sakai
Journal:  Surg Endosc       Date:  2017-03-09       Impact factor: 4.584

6.  Maximal blood flow acceleration analysis in the early diastolic phase for aortocoronary artery bypass grafts: a new transit-time flow measurement predictor of graft failure following coronary artery bypass grafting.

Authors:  Takemi Handa; Kazumasa Orihashi; Hideaki Nishimori; Masaki Yamamoto
Journal:  Surg Today       Date:  2016-03-19       Impact factor: 2.549

7.  The use of indocyanine green fluorescence to assess anastomotic perfusion during robotic assisted laparoscopic rectal surgery.

Authors:  Mehraneh D Jafari; Kang Hong Lee; Wissam J Halabi; Steven D Mills; Joseph C Carmichael; Michael J Stamos; Alessio Pigazzi
Journal:  Surg Endosc       Date:  2013-02-13       Impact factor: 4.584

Review 8.  Strategies for the coronary surgeon to remain "competitive and co-operative" in the PCI era.

Authors:  George Jose Valooran; Shiv Kumar Nair; Krishnan Chandrasekharan
Journal:  Indian Heart J       Date:  2015-07-08

9.  Novel techniques of real-time blood flow and functional mapping: technical note.

Authors:  Kyousuke Kamada; Hiroshi Ogawa; Masato Saito; Yukie Tamura; Ryogo Anei; Christoph Kapeller; Hideaki Hayashi; Robert Prueckl; Christoph Guger
Journal:  Neurol Med Chir (Tokyo)       Date:  2014-09-29       Impact factor: 1.742

10.  Intraoperative indocyanine green angiography for the objective measurement of blood flow.

Authors:  Jin Hyun Joh; Ho-Chul Park; Sang-Ah Han; Hyung Joon Ahn
Journal:  Ann Surg Treat Res       Date:  2016-05-02       Impact factor: 1.859

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.