Mobile-bearing insert translational and rotational kinematics in a PCL-retaining total knee arthroplasty.

J Chouteau1, J-L Lerat, R Testa, B Moyen, M-H Fessy, S A Banks.   

Abstract

INTRODUCTION: Total knee prostheses with a mobile-bearing insert were developed to provide nonconstrained joint range of motion while reducing friction forces. The purpose of this study was, based on weightbearing X-rays, to evaluate the mobility of the polyethylene tibial insert in relation to the femoral and tibial components. We studied the results of a cementless total knee arthroplasty (TKA) retaining the posterior cruciate ligament (PCL), with a mobile-bearing platform in rotation and anteroposterior translation (Innex Anterior-Posterior Glide, Zimmer) with a mean 23-month follow-up duration after surgery. HYPOTHESIS: Both anterior-posterior tibiofemoral translation and intraprosthetic axial rotation occur between the mobile polyethylene insert and the tibial endplate. MATERIAL AND
METHOD: In a series of 51 primary TKA, the three-dimensional (3D) kinematics of the femoral, tibial, and mobile insert components were determined using a computerized matching system between the prosthetic 3D models and the radiographic images of the implants on three lateral follow-up weightbearing knee X-rays: films were taken in full extension, at 45 degrees flexion, and at maximum flexion.
RESULTS: There was a statistically significant increase in the internal rotation of the mobile tray with flexion, (up to a mean -3+/-3 degrees between the femoral box and the mobile tray [p<0.0001] and up to a mean -5+/-7 degrees between the tibial tray and the mobile tray [p<0.0001]). The mobile tray did not translate in relation to the tibial endplate from extension to 45 degrees flexion (0+/-2 mm [range: -5 to 6 mm]). However, from 45 degrees to maximum flexion, a statistically significant mean 1+/-2 mm (range: -2 to 9 mm) of anterior translation (p<0.0001) was found. DISCUSSION: The extent of insert mobility varies from one study to another. Some have reported relatively limited mobility stemming from a superior surface that is not highly congruent, (thus allowing anterior-posterior and mediolateral translation through gliding of the femur in contact with the insert). Other studies have reported mobile-bearing tray mobility in relation to the tibial endplate and minimal rotation at the femoral component level. In this series of PCL retaining TKA with a mobile-bearing platform, the mobile-bearing platform showed a progressive increase in internal rotation during flexion. Most of this rotational mobility occurred between the mobile platform and the tibial endplate, confirming our hypothesis. However, with flexion, the femoral component increased its mobility relatively to the platform. During flexion, an anterior-posterior translation occurred between the femoral implant and the tibial insert, and between the tibial insert and the tibial endplate, but the direction of the mobile tibial insert translation remained unpredictable with this nonconstrained implant design used. LEVEL OF EVIDENCE: Level IV. Prospective non-controlled therapeutic study. 2009 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19442597     DOI: 10.1016/j.otsr.2009.03.012

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  8 in total

1.  Kinematics of a highly congruent mobile-bearing total knee prosthesis.

Authors:  N Wolterbeek; E H Garling; B J A Mertens; H M J van der Linden; R G H H Nelissen; E R Valstar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-17       Impact factor: 4.342

2.  No difference in ROM and knee function between mobile and floating platforms in TKA.

Authors:  Johannes Holinka; Navid Bahrami; Richard Lass; Sophie Frantal; Reinhard Windhager; Hugo Axel Wanivenhaus
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-29       Impact factor: 4.342

3.  Wear damage in mobile-bearing TKA is as severe as that in fixed-bearing TKA.

Authors:  Natalie H Kelly; Rose H Fu; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

4.  Single-radius, multidirectional total knee replacement.

Authors:  Jean-Yves Jenny; Rolf Miehlke; Dominique Saragaglia; Robert Geyer; Numa Mercier; Jean-Yves Schoenahl; Birger Thiel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-08-28       Impact factor: 4.342

5.  3D kinematics of mobile-bearing total knee arthroplasty using X-ray fluoroscopy.

Authors:  Takaharu Yamazaki; Kazuma Futai; Tetsuya Tomita; Yoshinobu Sato; Hideki Yoshikawa; Shinichi Tamura; Kazuomi Sugamoto
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-06-26       Impact factor: 2.924

6.  [Spin out - an avoidable complication in total knee replacement].

Authors:  M N Magin
Journal:  Orthopade       Date:  2014-02       Impact factor: 1.087

7.  Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations.

Authors:  Melinda K Harman; Scott A Banks; Stephan Kirschner; Jörg Lützner
Journal:  BMC Musculoskelet Disord       Date:  2012-10-23       Impact factor: 2.362

8.  Comparison of fixed- and mobile-bearing total knee arthroplasty with a mean five-year follow-up: A meta-analysis.

Authors:  Mengqi Cheng; Desheng Chen; Yongyuan Guo; Chen Zhu; Xianlong Zhang
Journal:  Exp Ther Med       Date:  2013-05-17       Impact factor: 2.447

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.