Literature DB >> 19442524

The human sacrum and safe approaches for screw placement.

Candan Arman1, Sait Naderi, Amaç Kiray, Funda Taştekin Aksu, Hakan Sinan Yilmaz, Süleyman Tetik, Esin Korman.   

Abstract

The human sacrum is the target of lumbosacral instrumentation and decompression procedures. Such surgical interventions require detailed knowledge of the anatomy of the human sacrum. The aim of this study was to measure surgically relevant parameters. Several factors, including the one-piece composition of the sacrum, the angles of the sacral pedicles and the anteroposterior diameter of the sacral vertebral bodies distinguish the sacrum from other parts of spine. Thirty-two measurements of shape, angles and distances between parts were taken of the sacra of 100 adult West Anatolian people using a Vernier caliper accurate to 0.1 mm and goniometer. According to this morphometric study, when measured from the sagittal, the S1 facet angle was measured as 35.71 degrees +/-9.59 and 34.70 degrees +/-9.66, the sacral pedicle anteromedial screw trajectory angle was 35.65 degrees +/-4.73 and 31.95 degrees +/-3.95 and the anterolaterally oriented sacral wing screw trajectory angle was 32.65 degrees +/-3.51 and 29.10 degrees +/-3.14, on the right and left sides, respectively. The distance of the midline oriented S1 pedicle screw was 51.12 mm and 51.26 mm on the right and left side, respectively. The distance for sacral wing oriented screw placement was 50.13 mm and 50.46 mm on the right and left side, respectively. The anteroposterior and transverse diameter of the sacral spinal canal were 21.81 mm and 31.31 mm, respectively. Thus, this study describes anatomical specifications of the sacrum. These defined morphometric details should be taken into consideration during surgical procedures. This study also describes anatomical landmarks which will allow injury of the sacrum during surgery to be avoided.

Entities:  

Mesh:

Year:  2009        PMID: 19442524     DOI: 10.1016/j.jocn.2008.07.081

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  13 in total

1.  A study of sacral anthropometry to determine S1 screw placement for spinal lumbosacral fixation in the Korean population.

Authors:  Young-Yul Kim; Kee-Yong Ha; Sang-Il Kim; In-Soo Oh
Journal:  Eur Spine J       Date:  2015-07-31       Impact factor: 3.134

2.  Anatomical considerations of safe drilling corridor upper sacral segment screw insertion.

Authors:  Hassan Bagheri; Figen Govsa
Journal:  J Orthop       Date:  2019-05-03

3.  L5 nerve root injury caused by anterolateral malpositioning of loosened S1 pedicle screws: illustrative cases.

Authors:  Shota Tamagawa; Takatoshi Okuda; Hidetoshi Nojiri; Rei Momomura; Muneaki Ishijima
Journal:  J Neurosurg Case Lessons       Date:  2021-06-21

4.  Can intermuscular cleavage planes provide proper transverse screw angle? Comparison of two paraspinal approaches.

Authors:  Xiaofei Cheng; Bin Ni; Qi Liu; Jinshui Chen; Huapeng Guan
Journal:  Eur Spine J       Date:  2012-08-11       Impact factor: 3.134

5.  L5 spinal nerve injury caused by misplacement of outwardly-inserted S1 pedicle screws.

Authors:  Masahiro Inoue; Gen Inoue; Tomoyuki Ozawa; Masayuki Miyagi; Hiroto Kamoda; Tetsuhiro Ishikawa; Miyako Suzuki; Yoshihiro Sakuma; Yasuhiro Oikawa; Kazuyo Yamauchi; Sumihisa Orita; Masashi Takaso; Tomoaki Toyone; Kazuhisa Takahashi; Seiji Ohtori
Journal:  Eur Spine J       Date:  2012-12-28       Impact factor: 3.134

6.  High incidence of persistence of sacral and coccygeal intervertebral discs in South Indians - a cadaveric study.

Authors:  B Satheesha Nayak; P Ashwini Aithal; Naveen Kumar; Bincy M George; R Deepthinath; Surekha D Shetty
Journal:  J Can Chiropr Assoc       Date:  2016-06

7.  Reinforcement of lumbosacral instrumentation using S1-pedicle screws combined with S2-alar screws.

Authors:  H Koller; J Zenner; A Hempfing; L Ferraris; O Meier
Journal:  Oper Orthop Traumatol       Date:  2013-06       Impact factor: 1.154

8.  Investigation of bone quality of the first and second sacral segments amongst trauma patients: concerns about iliosacral screw fixation.

Authors:  Dane Salazar; Sean Lannon; Olga Pasternak; Adam Schiff; Laurie Lomasney; Erika Mitchell; Michael Stover
Journal:  J Orthop Traumatol       Date:  2015-05-28

9.  Sacro-Iliac Joint Sensory Block and Radiofrequency Ablation: Assessment of Bony Landmarks Relevant for Image-Guided Procedures.

Authors:  Trevor J G Robinson; Shannon L Roberts; Robert S Burnham; Eldon Loh; Anne M Agur
Journal:  Biomed Res Int       Date:  2016-09-22       Impact factor: 3.411

Review 10.  Evidence-based support for S1 transpedicular screw entry point modification.

Authors:  Lukasz Kubaszewski; Andrzej Nowakowski; Jacek Kaczmarczyk
Journal:  J Orthop Surg Res       Date:  2014-04-03       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.