Literature DB >> 19440795

Severe complication of laparoscopic mesh hiatoplasty for paraesophageal hernia.

Nico Zügel1, Reinhold A Lang, Martin Kox, Thomas P Hüttl.   

Abstract

BACKGROUND: Several studies have shown that laparoscopic hernia repair for large paraesophageal hiatal hernia is associated with a high recurrence rate. Therefore, some authors recommend the use of prosthetic meshes. Considering the dynamic area between the esophagus and the diaphragmatic crura with its constant motion, it is astonishing that only a minor number of surgeons describe mesh-associated complications.
METHODS: Between January 2000 and August 2008, 26 patients of the Centre Hospitalier Emile Mayrisch (CHEM, Luxembourg) underwent laparoscopic repair for large paraesophageal hiatal hernia (median age, 70 (range, 39-90) years). In nine patients, prosthetic mesh reinforcement was performed (7 composite/2 mono-phase mesh). Crural repair without tension was performed only with sutures. There were no conversions. Follow-up assessment was prospective with the GIQL (Gastro-Intestinal Quality of Life) Index.
RESULTS: Responses to the GIQLI questionnaires were obtained from 20 patients (6 died of unrelated causes). Nineteen patients were satisfied with their symptom control 1 year after the operation (GIQLI 127). Sixteen patients had radiological follow-up (median, 24 months). Three patients treated without mesh (3/10) showed a radiological recurrence. All of them (3/10) had symptoms. None of the controlled patients with mesh (0/6) showed a recurrence. One patient developed a severe aortal bleeding 1, 2, and 3 weeks after the laparoscopic mono-phase mesh repair. During conventional operation, the bleeding stopped. Three years later, the follow-up showed a satisfied patient (GIQLI 127).
CONCLUSIONS: In view of the described complication, there is still considerable controversy regarding the routine use of mesh. To increase safety, a composite mesh should be preferred.

Entities:  

Mesh:

Year:  2009        PMID: 19440795     DOI: 10.1007/s00464-009-0456-9

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  36 in total

1.  [Dislocation into the cardial lumen of a PTFE prosthesis used in the treatment of voluminous hiatal sliding hernia, A case report].

Authors:  G Coluccio; S Ponzio; V Ambu; R Tramontano; G Cuomo
Journal:  Minerva Chir       Date:  2000-05       Impact factor: 1.000

2.  Systematic use of gastric fundoplication in laparoscopic repair of paraesophageal hernias.

Authors:  F Casabella; M Sinanan; S Horgan; C A Pellegrini
Journal:  Am J Surg       Date:  1996-05       Impact factor: 2.565

Review 3.  Laparoscopic mesh hiatoplasty for paraesophageal hernias and fundoplications: a critical analysis of the available literature.

Authors:  J M Johnson; A M Carbonell; B J Carmody; M K Jamal; J W Maher; J M Kellum; E J DeMaria
Journal:  Surg Endosc       Date:  2006-01-25       Impact factor: 4.584

4.  Ileocutaneous fistula formation following laparoscopic polypropylene mesh hernia repair.

Authors:  K Miller; W Junger
Journal:  Surg Endosc       Date:  1997-07       Impact factor: 4.584

5.  Fatal cardiac tamponade after emergency tension-free repair of a large paraesophageal hernia.

Authors:  E Kemppainen; T Kiviluoto
Journal:  Surg Endosc       Date:  2000-05-08       Impact factor: 4.584

Review 6.  Laparoscopic paraesophageal hernia repair.

Authors:  M E Freeman; R A Hinder
Journal:  Semin Laparosc Surg       Date:  2001-12

7.  A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia.

Authors:  Constantine T Frantzides; Atul K Madan; Mark A Carlson; George P Stavropoulos
Journal:  Arch Surg       Date:  2002-06

8.  Entero-colocutaneous fistula: a late consequence of polypropylene mesh abdominal wall repair: case report and review of the literature.

Authors:  J E Losanoff; B W Richman; J W Jones
Journal:  Hernia       Date:  2002-07-20       Impact factor: 4.739

9.  Teflon pledget reinforced fundoplication causes symptomatic gastric and esophageal lumenal penetration.

Authors:  Elizabeth Dally; Gregory L Falk
Journal:  Am J Surg       Date:  2004-02       Impact factor: 2.565

10.  Management of intrathoracic stomach with polypropylene mesh prosthesis reinforced transabdominal hiatus hernia repair.

Authors:  M A Carlson; R E Condon; K A Ludwig; W J Schulte
Journal:  J Am Coll Surg       Date:  1998-09       Impact factor: 6.113

View more
  13 in total

1.  Aortic injury during laparoscopic esophageal hiatoplasty.

Authors:  Oscar Cano-Valderrama; Almudena Marinero; Andrés Sánchez-Pernaute; Inmaculada Domínguez-Serrano; Elia Pérez-Aguirre; Antonio J Torres
Journal:  Surg Endosc       Date:  2013-02-23       Impact factor: 4.584

2.  Gasless laparoscopic surgery plus abdominal wall lifting for giant hiatal hernia-our single-center experience.

Authors:  Jiang-Hong Yu; Ji-Xiang Wu; Lei Yu; Jian-Ye Li
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2016-12-07

3.  The safety of biologic mesh for laparoscopic repair of large, complicated hiatal hernia.

Authors:  Eelco B Wassenaar; Fernando Mier; Huseyin Sinan; Rebecca P Petersen; A Valeria Martin; Carlos A Pellegrini; Brant K Oelschlager
Journal:  Surg Endosc       Date:  2011-11-16       Impact factor: 4.584

4.  Laparoscopic repair of paraesophageal hernia with anterior gastropexy: a multicenter study.

Authors:  Christopher R Daigle; Peter Funch-Jensen; Dan Calatayud; Peter Rask; Bo Jacobsen; Teodor P Grantcharov
Journal:  Surg Endosc       Date:  2014-10-08       Impact factor: 4.584

5.  Mesh erosion after hiatal hernia repair: the tip of the iceberg?

Authors:  J Li; T Cheng
Journal:  Hernia       Date:  2019-07-23       Impact factor: 4.739

6.  Laparoscopic mesh repair and Toupet fundoplication for parahiatal hernia complicated by sliding hiatal hernia: A case report.

Authors:  Risa Muramatsu; Takayuki Nobuoka; Tatsuya Ito; Tadashi Ogawa; Takahiro Korai; Ichiro Takemasa
Journal:  Int J Surg Case Rep       Date:  2022-09-14

Review 7.  [Antireflux operations: indications and techniques].

Authors:  H Feussner; D Wilhelm
Journal:  Chirurg       Date:  2013-04       Impact factor: 0.955

8.  Long-term results and complications related to Crurasoft® mesh repair for paraesophageal hiatal hernias.

Authors:  P Priego; J Perez de Oteyza; J Galindo; P Carda; F García-Moreno; G Rodríguez Velasco; E Lobo
Journal:  Hernia       Date:  2016-03-29       Impact factor: 4.739

9.  Preliminary study of hiatal hernia repair using polyglycolic acid: trimethylene carbonate mesh.

Authors:  James M Massullo; Tejinder P Singh; Ward J Dunnican; Brian R Binetti
Journal:  JSLS       Date:  2012 Jan-Mar       Impact factor: 2.172

10.  Management of acute upside-down stomach.

Authors:  Tobias S Schiergens; Michael N Thomas; Thomas P Hüttl; Wolfgang E Thasler
Journal:  BMC Surg       Date:  2013-11-15       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.