Literature DB >> 19438936

A comparison study of the osseointegration of zirconia and titanium dental implants. A biomechanical evaluation in the maxilla of pigs.

Michael Gahlert1, Stefan Röhling, Marco Wieland, Stefan Eichhorn, Helmut Küchenhoff, Heinz Kniha.   

Abstract

OBJECTIVES: The purpose of the present study was to investigate the osseointegration of microstructured zirconia implants in comparison with sandblasted and acid-etched (SLA) titanium implants in a biomechanical study. MATERIALS: Zirconia implants (4.1 mm in diameter, 10 mm in length) were produced using a new low pressure injection molding technique. After that the implants were acid-etched with hydrofluoric acid. Standard Ti-SLA implants of the exact same shape served as controls. Six months after extraction of incisors 2 and 3, 16 adult pigs received a total of 64 implants in the maxillae. After 4, 8, and 12 weeks the animals were sacrificed, and 59 implants could be analyzed to removal torque (RTQ) testing.
RESULTS: The mean RTQ values for zirconia implants were 42.4 Ncm at 4 weeks, 69.6 Ncm at 8 weeks, and 69.3 Ncm at 12 weeks of healing, whereas RTQ values for the Ti-SLA implants were 42.1 Ncm, 75.0 Ncm, and 73.1 Ncm at corresponding time intervals. There is no statistical difference in RTQ values between Ti-SLA and zirconia implants at 8 weeks.
CONCLUSIONS: Within the limits of the present study it was concluded that acid-etching of zirconia implants enhances bone apposition resulting in RTQ values which were equivalent to that of Ti-SLA.
© 2009, Copyright the Authors. Journal Compilation © 2010, Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19438936     DOI: 10.1111/j.1708-8208.2009.00168.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  11 in total

Review 1.  Zirconia surface modifications for implant dentistry.

Authors:  Fernanda H Schünemann; María E Galárraga-Vinueza; Ricardo Magini; Márcio Fredel; Filipe Silva; Júlio C M Souza; Yu Zhang; Bruno Henriques
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2019-01-16       Impact factor: 7.328

2.  Success and patient satisfaction of immediately loaded zirconia implants with fixed restorations one year after loading.

Authors:  Rico Rutkowski; Ralf Smeets; Leon Neuhöffer; Carolin Stolzer; Kilian Strick; Martin Gosau; Susanne Sehner; Karl Ulrich Volz; Anders Henningsen
Journal:  BMC Oral Health       Date:  2022-05-23       Impact factor: 3.747

3.  Surface alterations of zirconia and titanium substrates after Er,Cr:YSGG irradiation.

Authors:  Persio Vasconcelos Miranda; José Augusto Rodrigues; Alberto Blay; Jamil Awad Shibli; Alessandra Cassoni
Journal:  Lasers Med Sci       Date:  2014-01-16       Impact factor: 3.161

4.  Surface modifications of dental ceramic implants with different glass solder matrices: in vitro analyses with human primary osteoblasts and epithelial cells.

Authors:  Jana Markhoff; Enrico Mick; Aurica Mitrovic; Juliane Pasold; Katharina Wegner; Rainer Bader
Journal:  Biomed Res Int       Date:  2014-09-14       Impact factor: 3.411

5.  Implant Supported Fixed Dental Prostheses Using a New Monotype Zirconia Implant-A Case Report.

Authors:  Stefan Roehling; Georges Ghazal; Thomas Borer; Florian Thieringer; Michael Gahlert
Journal:  Dent J (Basel)       Date:  2015-09-17

6.  New Coating Technique of Ceramic Implants with Different Glass Solder Matrices for Improved Osseointegration-Mechanical Investigations.

Authors:  Enrico Mick; Jana Markhoff; Aurica Mitrovic; Anika Jonitz; Rainer Bader
Journal:  Materials (Basel)       Date:  2013-09-11       Impact factor: 3.623

7.  A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-Up.

Authors:  Andrea Enrico Borgonovo; Susanna Ferrario; Carlo Maiorana; Virna Vavassori; Rachele Censi; Dino Re
Journal:  Int J Dent       Date:  2021-12-30

8.  In vivo and in vitro analysis in a rat model using zoledronate and alendronate medication: microbiological and scanning electron microscopy findings on peri-implant rat tissue.

Authors:  Ali Al-Ahmad; Ali Modabber; Kristian Kniha; Eva Miriam Buhl; Stephan Christian Möhlhenrich; Anna Bock; Frank Hölzle; Elmar Hellwig
Journal:  BMC Oral Health       Date:  2021-12-31       Impact factor: 2.757

9.  Clinical and Radiographic Outcomes of Zirconia Dental Implants-A Clinical Case Series Study.

Authors:  Jordi Gargallo-Albiol; Karl Böhm; Hom-Lay Wang
Journal:  Materials (Basel)       Date:  2022-03-25       Impact factor: 3.623

10.  In vitro surface characteristics and impurity analysis of five different commercially available dental zirconia implants.

Authors:  B Beger; H Goetz; M Morlock; E Schiegnitz; B Al-Nawas
Journal:  Int J Implant Dent       Date:  2018-04-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.