Literature DB >> 19427097

Reliability and size of the measurement error when determining the cross-sectional area of the tibial nerve at the tarsal tunnel with ultrasonography.

Ali M Alshami1, Craig W Cairns, Bridie K Wylie, Tina Souvlis, Michel W Coppieters.   

Abstract

An in depth analysis of the reliability of ultrasonography to measure the cross-sectional area of the tibial nerve or any other peripheral nerve is not available in the literature. This study determined the reliability and size of the measurement error of high-resolution ultrasound to measure the size of the tibial nerve at the tarsal tunnel. The cross-sectional area of the tibial nerve was measured by two experienced sonographers at 1 cm proximal to the medial malleolus. Measurements were made in 10 healthy participants without plantar heel pain. Intra and intertester reliability were determined by calculation of intraclass correlation coefficients (ICC), measurement error magnitude and smallest detectable difference (SDD). A direct (tracing) and indirect (ellipsoid formula) method were evaluated. Results demonstrated that the intra and intertester reliability were excellent (ICC, all > or =0.86). The measurement error and SDD were very small, especially when measurements from three scans were averaged (measurement error: 0.4-0.9 mm2; SDD: 1.1-2.5 mm2). The findings of this study support the view that high-resolution ultrasound is reliable to measure the cross-sectional area of a peripheral nerve. As a result of the small measurement error, a side-to-side difference as small as approximately 1.8 mm2 can be interpreted meaningfully in an individual patient. This difference is much smaller than the swelling reported in the literature for patients with tibial neuropathy.

Entities:  

Mesh:

Year:  2009        PMID: 19427097     DOI: 10.1016/j.ultrasmedbio.2009.01.011

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  11 in total

1.  Anatomical bases of endoscopic tarsal tunnel release: anatomical and ultra-sonographic study with a preliminary clinical report.

Authors:  Ossama El Shazly; Ayman El Shazly; Ahmed Desouky; Abeer Kadry El Zohiery; Hossam Moussa Sakr
Journal:  Surg Radiol Anat       Date:  2011-10-29       Impact factor: 1.246

2.  The pattern of tibial nerve excursion with active ankle dorsiflexion is different in older people with diabetes mellitus.

Authors:  Benjamin S Boyd; Andrew T Gray; Andrew Dilley; Linda Wanek; Kimberly S Topp
Journal:  Clin Biomech (Bristol, Avon)       Date:  2012-07-17       Impact factor: 2.063

3.  Novel Ultrasound Anatomical Measurement of the Deep Transverse Metatarsal Ligament: An Intra-Rater Reliability and Inter-Rater Concordance Study.

Authors:  María Del Mar Ruiz-Herrera; Félix Marcos-Tejedor; Alberto Aldana-Caballero; César Calvo-Lobo; David Rodriguez-Sanz; Simone Moroni; Marko Konschake; Alicia Mohedano-Moriano; Javier Aceituno-Gómez; Juan José Criado-Álvarez
Journal:  J Clin Med       Date:  2022-05-02       Impact factor: 4.964

4.  A comparison of portable ultrasound and fully-equipped clinical ultrasound unit in the thyroid size measurement of the Indo-Pacific bottlenose dolphin.

Authors:  Brian C W Kot; Michael T C Ying; Fiona M Brook
Journal:  PLoS One       Date:  2012-01-17       Impact factor: 3.240

5.  Ultrasonographic reference values for assessing normal radial nerve ultrasonography in the normal population.

Authors:  Jun Chen; Shan Wu; Jun Ren
Journal:  Neural Regen Res       Date:  2014-10-15       Impact factor: 5.135

6.  Test-retest reliability of nerve and muscle morphometric characteristics utilizing ultrasound imaging in individuals with unilateral sciatica and controls.

Authors:  Hadi Sarafraz; Mohammad Reza Hadian; Niloofar Ayoobi Yazdi; Gholamreza Olyaei; Hossein Bagheri; Shohreh Jalaie; Omid Rasouli
Journal:  Chiropr Man Therap       Date:  2018-11-06

7.  Can ultrasound of the tibial nerve detect diabetic peripheral neuropathy? A cross-sectional study.

Authors:  Sheila Riazi; Vera Bril; Bruce A Perkins; Sherif Abbas; Vincent W S Chan; Mylan Ngo; Leif E Lovblom; Hossam El-Beheiry; Richard Brull
Journal:  Diabetes Care       Date:  2012-10-01       Impact factor: 19.112

8.  High-Resolution Ultrasonography of the Superficial Peroneal Motor and Sural Sensory Nerves May Be a Non-invasive Approach to the Diagnosis of Vasculitic Neuropathy.

Authors:  Nurcan Üçeyler; Kristina A Schäfer; Daniel Mackenrodt; Claudia Sommer; Wolfgang Müllges
Journal:  Front Neurol       Date:  2016-03-30       Impact factor: 4.003

9.  The feasibility of using high-resolution ultrasonography to assess ulnar nerve in patients with diabetes mellitus.

Authors:  Jun Chen; Chun-Lei Wang; Shan Wu; Shan He; Jun Ren
Journal:  J Ultrason       Date:  2017-09-29

10.  Reference values for the cross-sectional area of normal radial nerve at two levels using high-resolution ultrasonography.

Authors:  Kunwar Pal Singh; Achal Singh Goindi; Kamlesh Gupta
Journal:  J Ultrason       Date:  2021-06-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.