Reduction of the number of stacking layers in proton uniform scanning.

Shinichiro Fujitaka1, Taisuke Takayanagi, Rintaro Fujimoto, Yusuke Fujii, Hideaki Nishiuchi, Futaro Ebina, Takashi Okazaki, Kazuo Hiramoto, Takeji Sakae, Toshiyuki Terunuma.   

Abstract

Uniform scanning with a relatively large beam size can improve beam utilization efficiency more than conventional irradiation methods using scatterers and can achieve a large-field, long-range and large spread-out Bragg peak (SOBP). The SOBP is obtained by energy stacking in uniform scanning, but its disadvantage is that the number of stacking layers is large, especially in the low-energy region, because the Bragg peak of the pristine beam is very sharp. We applied a mini-ridge filter to broaden the pristine Bragg peak up to a stacked layer thickness of 1 or 2 cm in order to decrease the number of stacking layers. The number of stacking layers can be reduced to 20% or less than that in the case of pristine beam stacking. Although the distal falloff of the SOBP is deteriorated by applying the mini-ridge filter, we can improve the distal falloff to that of pristine beam stacking by introducing the distal filter to the irradiation of the most distal layer. Uniform scanning in combination with mini-ridge filter use can more than double the beam utilization efficiency over that of passive irradiation techniques.

Mesh:

Substances:

Year:  2009        PMID: 19420427     DOI: 10.1088/0031-9155/54/10/009

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  Synchrotron-Based Pencil Beam Scanning Nozzle with an Integrated Mini-Ridge Filter: A Dosimetric Study to Optimize Treatment Delivery.

Authors:  Xianliang Wang; Yupeng Li; Xiaodong Zhang; Heng Li; Koichi Miyazaki; Rintaro Fujimoto; Hiroshi Akiyama; Michael T Gillin; Falk Poenisch; Narayan Sahoo; David Grosshans; Brandon Gunn; Steven Jay Frank; Pei Wang; Jinyi Lang; Qing Hou; Xiaorong Ronald Zhu
Journal:  Cancers (Basel)       Date:  2017-12-13       Impact factor: 6.639

2.  Quantitative analysis of treatments using real-time image gated spot-scanning with synchrotron-based proton beam therapy system log data.

Authors:  Takaaki Yoshimura; Shinichi Shimizu; Takayuki Hashimoto; Kentaro Nishioka; Norio Katoh; Hiroshi Taguchi; Koichi Yasuda; Taeko Matsuura; Seishin Takao; Masaya Tamura; Sodai Tanaka; Yoichi M Ito; Yuto Matsuo; Hiroshi Tamura; Kenji Horita; Kikuo Umegaki; Hiroki Shirato
Journal:  J Appl Clin Med Phys       Date:  2020-11-05       Impact factor: 2.102