Literature DB >> 19417813

Simultaneous imaging and optode calibration with diffuse optical tomography.

D Boas, T Gaudette, S Arridge.   

Abstract

In order for diffuse optical tomography to realize its potential of obtaining quantitative images of spatially varying optical properties within random media, several potential experimental systematic errors must be overcome. One of these errors is the calibration of the emitter strength and detector efficiency/gain. While in principle these parameters can be determined accurately prior to an imaging experiment, slight fluctuations will cause significant image artifacts. For this reason, it is necessary to consider including their calibration as part of the inverse problem for image reconstruction. In this paper, we show that this can be done successfully in a linear reconstruction model with simulated continuous-wave data. The technique is general for frequency and time domain data.

Year:  2001        PMID: 19417813     DOI: 10.1364/oe.8.000263

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  21 in total

1.  Transabdominal near infrared oximetry of hypoxic stress in fetal sheep brain in utero.

Authors:  Regine Choe; Turgut Durduran; Guoqiang Yu; Mark J M Nijland; Britton Chance; Arjun G Yodh; Nirmala Ramanujam
Journal:  Proc Natl Acad Sci U S A       Date:  2003-10-16       Impact factor: 11.205

2.  Lifetime-based tomographic multiplexing.

Authors:  Scott B Raymond; David A Boas; Brian J Bacskai; Anand T N Kumar
Journal:  J Biomed Opt       Date:  2010 Jul-Aug       Impact factor: 3.170

3.  Combined optical and X-ray tomosynthesis breast imaging.

Authors:  Qianqian Fang; Juliette Selb; Stefan A Carp; Gregory Boverman; Eric L Miller; Dana H Brooks; Richard H Moore; Daniel B Kopans; David A Boas
Journal:  Radiology       Date:  2010-11-09       Impact factor: 11.105

4.  Application of spectral derivative data in visible and near-infrared spectroscopy.

Authors:  Hamid Dehghani; Frederic Leblond; Brian W Pogue; Fabien Chauchard
Journal:  Phys Med Biol       Date:  2010-05-26       Impact factor: 3.609

5.  A time domain fluorescence tomography system for small animal imaging.

Authors:  Anand T N Kumar; Scott B Raymond; Andrew K Dunn; Brian J Bacskai; David A Boas
Journal:  IEEE Trans Med Imaging       Date:  2008-08       Impact factor: 10.048

6.  Compensation of optode sensitivity and position errors in diffuse optical tomography using the approximation error approach.

Authors:  Meghdoot Mozumder; Tanja Tarvainen; Simon R Arridge; Jari Kaipio; Ville Kolehmainen
Journal:  Biomed Opt Express       Date:  2013-09-06       Impact factor: 3.732

7.  Implementation of a computationally efficient least-squares algorithm for highly under-determined three-dimensional diffuse optical tomography problems.

Authors:  Phaneendra K Yalavarthy; Daniel R Lynch; Brian W Pogue; Hamid Dehghani; Keith D Paulsen
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

8.  Hyperspectral wide-field time domain single-pixel diffuse optical tomography platform.

Authors:  Qi Pian; Ruoyang Yao; Xavier Intes
Journal:  Biomed Opt Express       Date:  2018-11-15       Impact factor: 3.732

9.  Direct approach to compute Jacobians for diffuse optical tomography using perturbation Monte Carlo-based photon "replay".

Authors:  Ruoyang Yao; Xavier Intes; Qianqian Fang
Journal:  Biomed Opt Express       Date:  2018-09-04       Impact factor: 3.732

Review 10.  Optical brain imaging in vivo: techniques and applications from animal to man.

Authors:  Elizabeth M C Hillman
Journal:  J Biomed Opt       Date:  2007 Sep-Oct       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.