Clinical outcomes of short hook wire and suture marking system in thoracoscopic resection for pulmonary nodules.

Kentaroh Miyoshi1, Shinichi Toyooka, Hideo Gobara, Takahiro Oto, Hidefumi Mimura, Yoshifumi Sano, Susumu Kanazawa, Hiroshi Date.   

Abstract

OBJECTIVE: The short hook wire and suture marking system is a device for localization of small pulmonary nodules in thoracoscopic resection. We and other authors have shown the feasibility of the marking procedure. In this study, we reviewed our recent experience to examine the problems for resecting procedure using the device and determine if the system negatively impacts the survival rates for lung cancers.
METHODS: Between November 1996 and March 2007, a total of 125 pulmonary nodular lesions in 108 patients were intended for thoracoscopic resection after localization with computed tomography-guided short hook wire and suture placement. We reviewed the major problems during surgery among all cases and prognosis in 64 patients with primary lung cancer.
RESULTS: One hundred and seventeen lesions (93.6%) were successfully resected by initial resection with no major complication. However, we experienced missing events, the major problem during surgery, which was defined as temporarily missing lesions or hook wires. Eight missing events (6.4%) consisting of five unresected lesions and three remaining hook wires occurred after initial wedge resection. All the missing lesions and one remaining hook wire were recovered by additional resection. No specific factors of lesions, including location, diameter, distance from the pleural surface, and opacification were related to incidence of the 'missing event'. Five-year survival of patients with stage IA lung cancer was 90.0% with no local recurrence.
CONCLUSIONS: Our localization method assured a consistent quality of resection regardless of the lesion characteristics and a reasonable prognosis for patients with primary lung cancer. The short hook wire and suture system provides acceptable utility in thoracoscopic surgery.

Entities:  

Mesh:

Year:  2009        PMID: 19414272     DOI: 10.1016/j.ejcts.2009.03.039

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  30 in total

1.  Diagnostic and therapeutic value of computed tomography guided coil placement after digital subtraction angiography guided video-assisted thoracoscopic surgery resection for solitary pulmonary nodules.

Authors:  Yong Qiang; Lei Zhang; Nan Yang; Jian Xu; De-Min Li; Tangfeng Lv; Ping Zhan; Yong Song; Zhong-Dong Li; Hao Li
Journal:  Transl Lung Cancer Res       Date:  2015-10

2.  Imaging-guided thoracoscopic resection of a ground-glass opacity lesion in a hybrid operating room equipped with a robotic C-arm CT system.

Authors:  Chen-Ping Hsieh; Ming-Ju Hsieh; Hsin-Yueh Fang; Yin-Kai Chao
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

Review 3.  Image-guided techniques for localizing pulmonary nodules in thoracoscopic surgery.

Authors:  Mong-Wei Lin; Jin-Shing Chen
Journal:  J Thorac Dis       Date:  2016-10       Impact factor: 2.895

4.  Localizing small lung lesions in video-assisted thoracoscopic surgery via radiofrequency identification marking.

Authors:  Yojiro Yutaka; Toshihiko Sato; Jitian Zhang; Koichi Matsushita; Hiroyuki Aiba; Yusuke Muranishi; Yasuto Sakaguchi; Teruya Komatsu; Fumitsugu Kojima; Tatsuo Nakamura; Hiroshi Date
Journal:  Surg Endosc       Date:  2016-12-23       Impact factor: 4.584

5.  Comparison between the application of microcoil and hookwire for localizing pulmonary nodules.

Authors:  Libao Hu; Jian Gao; Chen Chen; Xin Zhi; Huixin Liu; Nan Hong
Journal:  Eur Radiol       Date:  2019-01-10       Impact factor: 5.315

6.  Combination of CT-guided hookwire localization and video-assisted thoracoscopic surgery for pulmonary nodular lesions: Analysis of 103 patients.

Authors:  Wentao Li; Ying Wang; Xinhong He; Guodong Li; Shengping Wang; Lichao Xu; Zheng Yuan
Journal:  Oncol Lett       Date:  2012-07-13       Impact factor: 2.967

Review 7.  Intraoperative fluorescence imaging in thoracic surgery.

Authors:  Andrew D Newton; Jarrod D Predina; Shuming Nie; Philip S Low; Sunil Singhal
Journal:  J Surg Oncol       Date:  2018-08-11       Impact factor: 3.454

8.  CT-guided microcoil VATS resection of lung nodules: a single-centre experience and review of the literature.

Authors:  Laura L Donahoe; Elsie T Nguyen; Tae-Bong Chung; Lan-Chau Kha; Marcelo Cypel; Gail E Darling; Marc de Perrot; Shaf Keshavjee; Andrew F Pierre; Thomas K Waddell; Kazuhiro Yasufuku
Journal:  J Thorac Dis       Date:  2016-08       Impact factor: 2.895

9.  Preoperative short hookwire placement for small pulmonary lesions: evaluation of technical success and risk factors for initial placement failure.

Authors:  Toshihiro Iguchi; Takao Hiraki; Yusuke Matsui; Hiroyasu Fujiwara; Yoshihisa Masaoka; Takashi Tanaka; Takuya Sato; Hideo Gobara; Shinichi Toyooka; Susumu Kanazawa
Journal:  Eur Radiol       Date:  2017-12-15       Impact factor: 5.315

10.  Doppler Ultrasound-Visible SignalMark Microspheres are Better Identified than HydroMARK® Clips in a Simulated Intraoperative Setting in Breast and Lung Tissue.

Authors:  Rachel K Voss; Erin P Ward; Haydee Ojeda-Fournier; Sarah L Blair
Journal:  Ann Surg Oncol       Date:  2018-09-03       Impact factor: 5.344

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.