Literature DB >> 19412115

Grading of aortic valve stenosis at 64-slice spiral computed tomography: comparison with transthoracic echocardiography and calibration against cardiac catheterization.

Alexander Lembcke1, Michael Woinke, Adrian C Borges, Pascal M Dohmen, André Lachnitt, Yvonne Westermann, Anja Geigenmueller, Kay G A Hermann, Craig Butler, Holger Thiele, Dietmar E Kivelitz.   

Abstract

PURPOSE: We sought to determine the accuracy of multislice spiral computed tomography (MSCT) for assessing of aortic valve stenosis and to establish threshold values of the planimetric aortic valve orifice area (AVA) that best separate between different grades of stenosis severity.
MATERIALS AND METHODS: A total of 202 patients (among them 160 patients with aortic valve stenosis) underwent MSCT, transthoracic echocardiography (TTE) and cardiac catheterization (CATH). Planimetric AVA measurements at MSCT were compared with calculations based on Doppler flow velocity measurements by TTE (using the continuity equation) and pressure gradient measurements by CATH (using the Gorlin formula).
RESULTS: Series of AVA measurements correlated well between MSCT and TTE (r = 0.86) and between MSCT and CATH (r = 0.90). However, AVA at MSCT (0.98 +/- 0.47 cm) was significantly larger than AVA at TTE (0.81 +/- 0.36 cm; P < 0.05) and CATH (0.80 +/- 0.39 cm; P < 0.05). For severity grades 0 through IV the AVAs at MSCT were 2.69 +/- 0.75, 1.86 +/- 0.30, 1.48 +/- 0.17, 0.95 +/- 0.20, and 0.68 +/- 0.20 cm, respectively. For separating, the 5 severity grades optimal thresholds at MSCT were 2.1, 1.6, 1.2, and 0.9 cm. Using these adjusted thresholds there was perfect agreement in classification between MSCT and CATH in 156 (77%), but a mismatch by 1 grade in 43 (21.5%) and 2 grades in 3 (1.5%) patients (kappaw = 0.86).
CONCLUSION: Planimetric AVA measurements on MSCT allows for an accurate grading of aortic valve stenosis severity. However, AVA measurements on MSCT are usually larger than measurements on TTE and CATH. Consequently, the thresholds for discriminating between different severity grades have to be adjusted in MSCT.

Entities:  

Mesh:

Year:  2009        PMID: 19412115     DOI: 10.1097/RLI.0b013e3181a64d76

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

1.  Aortic valve area assessed with 320-detector computed tomography: comparison with transthoracic echocardiography.

Authors:  Linnea Hornbech Larsen; Klaus Fuglsang Kofoed; Helle Gervig Carstensen; Mads Rams Mejdahl; Mads Jønsson Andersen; Jesper Kjaergaard; Olav Wendelboe Nielsen; Lars Køber; Rasmus Møgelvang; Christian Hassager
Journal:  Int J Cardiovasc Imaging       Date:  2013-10-15       Impact factor: 2.357

2.  Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis.

Authors:  Katarzyna Mizia-Stec; Piotr Pysz; Marek Jasiński; Tomasz Adamczyk; Agnieszka Drzewiecka-Gerber; Artur Chmiel; Michał Krejca; Andrzej Bochenek; Stanisław Woś; Maciej Sosnowski; Zbigniew Gąsior; Maria Trusz-Gluza; Michał Tendera
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

3.  Inconsistency in aortic stenosis severity between CT and echocardiography: prevalence and insights into mechanistic differences using computational fluid dynamics.

Authors:  Tarun Kumar Mittal; Luise Reichmuth; Sanjeev Bhattacharyya; Manish Jain; Aigul Baltabaeva; Shelley Rahman Haley; Saeed Mirsadraee; Vasileios Panoulas; Tito Kabir; Edward David Nicol; Miles Dalby; Quan Long
Journal:  Open Heart       Date:  2019-07-29

4.  Semiautomatic, Quantitative Measurement of Aortic Valve Area Using CTA: Validation and Comparison with Transthoracic Echocardiography.

Authors:  V Tuncay; N Prakken; P M A van Ooijen; R P J Budde; T Leiner; M Oudkerk
Journal:  Biomed Res Int       Date:  2015-06-29       Impact factor: 3.411

5.  Analysis of left ventricular function, left ventricular outflow tract and aortic valve area using computed tomography: Influence of reconstruction parameters on measurement accuracy.

Authors:  Michaela M Hell; Bettine Steinmann; Tassilo Scherkamp; Martin B Arnold; Stephan Achenbach; Mohamed Marwan
Journal:  Br J Radiol       Date:  2021-07-08       Impact factor: 3.039

  5 in total