Literature DB >> 19410064

Randomized controlled trial comparing a variable-thread novel tapered and a standard tapered implant: interim one-year results.

Andrej M Kielbassa1, Rafael Martinez-de Fuentes, Moshe Goldstein, Christoph Arnhart, Alberto Barlattani, Jochen Jackowski, Marko Knauf, Martin Lorenzoni, Carlo Maiorana, Regina Mericske-Stern, Eric Rompen, Mariano Sanz.   

Abstract

STATEMENT OF PROBLEM: A tapered implant with continuously changing threads purported to provide stable tissue support and allow immediate function has been developed. Treatment success and stabilization of supporting tissues over time require documentation.
PURPOSE: The purpose of this prospective, randomized, controlled, multicenter study was to evaluate changes in bone level and soft tissue behavior between the novel implant (NobelActive/NA) and a standard tapered implant (NobelReplace Tapered Groovy/NR) with regard to immediate function.
MATERIAL AND METHODS: A total of 177 patients randomly allocated to 3 treatment groups (2 different test implant groups: NA Internal (n=117; internal connection) and External (n=82), and 1 standard treatment group, NR (n=126)) received 325 implants. Implants were placed into healed sites, and all but 6 implants were immediately nonocclusally loaded. Clinical and radiographic evaluations of treatment success, crestal bone levels, and soft tissue changes were performed at the time of placement and after 3, 6, and 12 months. Log-Rank test was used to analyze the differences in survival rate. Marginal bone level was compared using the Kruskal-Wallis test and Mann-Whitney U-test (alpha=.05).
RESULTS: One-year cumulative survival rates were comparable (96.6% for NA Internal; 96.3% for NA External; 97.6% for NR; P=.852; Log-Rank). Mean (SD) change in bone level was -0.95 mm (1.37) for NA Internal, -0.64 mm (0.97) for NA External, and -0.63 mm (1.18) for NR (P=.589; Kruskal-Wallis). Stable soft tissues and significantly increased papilla scores (P<.001; Wilcoxon signed-rank) were observed for all implant types.
CONCLUSIONS: The novel implants showed high survival rates as well as stable bone and soft tissue levels after 1 year, and may be recommended for clinical use, even under immediate function.

Entities:  

Mesh:

Year:  2009        PMID: 19410064     DOI: 10.1016/S0022-3913(09)60060-3

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  14 in total

1.  Influence of platform switching on bone-level alterations: a three-year randomized clinical trial.

Authors:  N Enkling; P Jöhren; J Katsoulis; S Bayer; P-M Jervøe-Storm; R Mericske-Stern; S Jepsen
Journal:  J Dent Res       Date:  2013-10-24       Impact factor: 6.116

Review 2.  Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? A systematic review.

Authors:  Marcelo Coelho Goiato; Eduardo Piza Pellizzer; Emily Vivianne Freitas da Silva; Liliane da Rocha Bonatto; Daniela Micheline dos Santos
Journal:  Oral Maxillofac Surg       Date:  2015-04-25

Review 3.  WITHDRAWN: Interventions for replacing missing teeth: different types of dental implants.

Authors:  Marco Esposito; Yasmin Ardebili; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-10-10

4.  Comparison of Bone Loss around Bone Platform Shift and Non-Bone Platform Shift Implants After 12 Months.

Authors:  Amir Reza Rokn; Samareh Badri; Amir Alireza Rasouli Ghahroudi; Rebeca Manasheof; Mohamad Javad Kharazi Fard; Hamidreza Barikani
Journal:  J Dent (Tehran)       Date:  2015-03

5.  An open prospective single cohort multicenter study evaluating the novel, tapered, conical connection implants supporting single crowns in the anterior and premolar maxilla: interim 1-year results.

Authors:  Alexander Fügl; Werner Zechner; Alessandro Pozzi; Guido Heydecke; Christine Mirzakhanian; Nikolaus Behneke; Alexandra Behneke; Russell A Baer; Robert Nölken; Edward Gottesman; Snjezana Colic
Journal:  Clin Oral Investig       Date:  2016-11-18       Impact factor: 3.573

6.  Radiographic evaluation of conical tapered platform-switched implants in the posterior mandible: 1-year results of a two-center prospective study.

Authors:  Maximilian Moergel; Salomão Rocha; Ana Messias; Pedro Nicolau; Fernando Guerra; Wilfried Wagner
Journal:  Clin Oral Implants Res       Date:  2015-06-21       Impact factor: 5.977

7.  Peri-Implant Bone Resorption during Healing Abutment Placement: The Effect of a 0.20% Chlorhexidine Gel vs. Placebo-A Randomized Double Blind Controlled Human Study.

Authors:  Bruna Sinjari; Gianmaria D'Addazio; Ilaria De Tullio; Tonino Traini; Sergio Caputi
Journal:  Biomed Res Int       Date:  2018-10-16       Impact factor: 3.411

Review 8.  Impact of platform switching on marginal peri-implant bone-level changes. A systematic review and meta-analysis.

Authors:  Frank Peter Strietzel; Konrad Neumann; Moritz Hertel
Journal:  Clin Oral Implants Res       Date:  2014-01-20       Impact factor: 5.977

9.  Platform switch versus platform match in the posterior mandible – 1-year results of a multicentre randomized clinical trial.

Authors:  Fernando Guerra; Wilfried Wagner; Jörg Wiltfang; Salomão Rocha; Maximilian Moergel; Eleonore Behrens; Pedro Nicolau
Journal:  J Clin Periodontol       Date:  2014-05       Impact factor: 8.728

10.  Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical trial.

Authors:  Salomão Rocha; Wilfried Wagner; Jörg Wiltfang; Pedro Nicolau; Maximilian Moergel; Ana Messias; Eleonore Behrens; Fernando Guerra
Journal:  J Clin Periodontol       Date:  2016-03-30       Impact factor: 8.728

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.