Patterns of normal transvalvular regurgitation in mechanical valve prostheses.

F A Flachskampf1, J P O'Shea, B P Griffin, L Guerrero, A E Weyman, J D Thomas.   

Abstract

The magnitude and spatial distribution of normal leakage through mechanical prosthetic valves were studied in an in vitro model of mitral regurgitation. The effective regurgitant orifice was calculated from regurgitant rate at different transvalvular pressure differences and flow velocities. This effective orifice area was 0.6 to 2 mm2 for three tilting disc prostheses (Medtronic-Hall sizes 21, 25 and 29) and 0.2 to 1.1 mm2 for three bileaflet valves (St. Jude Medical sizes 21, 25 and 33). In the single disc valves, Doppler color flow examination disclosed a prominent central regurgitant jet around the central hole for the strut, accompanied by minor leakage along the rim of the disc (central to peripheral jet area ratio 3.3 +/- 1.2). The bileaflet prostheses showed a peculiar complex pattern: in planes parallel to the two disc axes, convergent peripherally arising jets were visualized, whereas in orthogonal planes several diverging jets were seen. Mounting the disc and bileaflet valves on a water-filled tube allowed reproduction and interpretation of this pattern: for the bileaflet valve, the jets originated predominantly from valve ring protrusions that contained the axis hinge points and created a converging V pattern in planes parallel to the leaflets and a diverging V pattern in orthogonal planes. Similar patterns were observed during transesophageal echocardiography in 20 patients with a normally functioning St. Jude prosthesis. In 10 patients with a Medtronic-Hall valve, a dominant central jet was observed with one or more smaller peripheral jets. The median central to peripheral jet area ratio was 5 to 1.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 1939951     DOI: 10.1016/0735-1097(91)90680-8

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  2 in total

1.  Assessing prosthetic mitral valve regurgitation by transoesophageal echo/Doppler.

Authors:  P S Rahko
Journal:  Heart       Date:  2004-05       Impact factor: 5.994

2.  Hemodynamic influence of tilting disc valve type on pump performance with the NIPRO-ventricular assist device.

Authors:  Mitsutoshi Kimura; Takashi Nishimura; Osamu Kinoshita; Koichi Kashiwa; Shunei Kyo; Minoru Ono
Journal:  J Artif Organs       Date:  2011-11-11       Impact factor: 1.731

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.