Literature DB >> 19393638

Point-of-care fluorescence immunoassay for prostate specific antigen.

Sang Wook Oh1, Young Min Kim, Hyun Jeong Kim, Sung Joong Kim, Jin-Sun Cho, Eui Yul Choi.   

Abstract

BACKGROUND: Prostate specific antigen (PSA) is widely used as a clinical marker for diagnosis, screening, and prognosis of prostate cancer. A fluorescence (FL) dye-incorporated immunochromatographic assay (ICA) was developed for detection of PSA concentration in whole blood or serum.
METHODS: Whole blood or serum mixed with FL-conjugated detector was loaded onto a cartridge and incubated for 12 min. The FL intensity of the cartridge was then measured in a laser FL scanner. The analytical performance of the FL-ICA system was evaluated by precision and recovery tests. The comparability of the new method was examined with an automated analyzer.
RESULTS: A reliable correlation between area ratio (AT/AC), reflecting FL intensity of test/control line, and PSA concentration was observed (r=0.998). The CVs of intra- and inter-assay precision in a range of 2.5-8 microg/l were <6.0% and 4.5%, respectively, and analytical recovery of the FL-ICA system fell within 6.5% at the tested samples. When the FL-ICA method was compared with Abbott AxSYM and Bayer Centaur analyzers, there were strong correlations (r=0.993 and r=0.992, p<0.0001).
CONCLUSION: The FL-ICA system with point-of-care-testing (POCT) appeared to be an easy, fast and suitable method for measurement of PSA concentration in whole blood, and needs no accessory equipment to separate serum.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19393638     DOI: 10.1016/j.cca.2009.04.013

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  7 in total

1.  Rapid and quantitative detection of C-reactive protein using quantum dots and immunochromatographic test strips.

Authors:  Xianglin Cheng; Xu Pu; Pen Jun; XiaoBo Zhu; Di Zhu; Ming Chen
Journal:  Int J Nanomedicine       Date:  2014-12-02

2.  Assessment of a new point-of-care system for detection of prostate specific antigen.

Authors:  Steffen Rausch; Joerg Hennenlotter; Josef Wiesenreiter; Andrea Hohneder; Julian Heinkele; Christian Schwentner; Arnulf Stenzl; Tilman Todenhöfer
Journal:  BMC Urol       Date:  2016-01-19       Impact factor: 2.264

Review 3.  Towards Lateral Flow Quantitative Assays: Detection Approaches.

Authors:  Alexandr E Urusov; Anatoly V Zherdev; Boris B Dzantiev
Journal:  Biosensors (Basel)       Date:  2019-07-17

4.  A fast and sensitive quantitative lateral flow immunoassay for Cry1Ab based on a novel signal amplification conjugate.

Authors:  Chunxiang Chen; Jian Wu
Journal:  Sensors (Basel)       Date:  2012-08-27       Impact factor: 3.576

5.  Development of a novel fluorophore for real-time biomonitoring system.

Authors:  Hyun-Ok Song; Binna Lee; Ram Prasad Bhusal; Byounghun Park; Kyoungsik Yu; Chom-Kyu Chong; PyoYun Cho; Sung Yeon Kim; Hak Sung Kim; Hyun Park
Journal:  PLoS One       Date:  2012-11-02       Impact factor: 3.240

6.  Immunochromatographic assay for ultrasensitive detection of aflatoxin B₁ in maize by highly luminescent quantum dot beads.

Authors:  Meiling Ren; Hengyi Xu; Xiaolin Huang; Min Kuang; Yonghua Xiong; Hong Xu; Yang Xu; Hongyu Chen; Andrew Wang
Journal:  ACS Appl Mater Interfaces       Date:  2014-08-18       Impact factor: 9.229

7.  Rough surface Au@Ag core-shell nanoparticles to fabricating high sensitivity SERS immunochromatographic sensors.

Authors:  Qiangqiang Fu; Hongwu Liu Liu; Ze Wu; An Liu; Cuize Yao; Xiuqing Li; Wei Xiao; Shiting Yu; Zhi Luo; Yong Tang
Journal:  J Nanobiotechnology       Date:  2015-11-14       Impact factor: 10.435

  7 in total