OBJECTIVE: We sought to determine the rate of de novo stress incontinence, pelvic muscle symptoms, mesh exposure, visceral injury rate, and recurrent prolapse after transvaginal mesh repair. STUDY
DESIGN: We conducted a retrospective review of 335 consecutive women with stage II or worse vaginal prolapse who underwent Prolift (Ethicon, Somerville, NJ) between July 7, 2005 and Jan. 31, 2008.
RESULTS: In all, 71% underwent total Prolift, 20% anterior, and 8% posterior alone. Average age was 62 years and mean follow-up was 8 months. The intraoperative visceral injury rate was 6.6%, mesh exposure rate was 3.8%, and recurrent failure rate was 5.2%. The postoperative de novo stress incontinence rate was 24.3%. In this series, 18% of women had pelvic muscle symptoms postoperatively; 74% of these resolved within 6 months with conservative management.
CONCLUSION: After Prolift, surgeons can expect a low rate of recurrent prolapse and mesh exposure. However, pelvic muscle dysfunction and de novo stress incontinence will be encountered postoperatively in a moderate number of women.

Entities:  

Mesh:

Year:  2009        PMID: 19393596     DOI: 10.1016/j.ajog.2009.02.028

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  8 in total

Review 1.  Evaluation of current synthetic mesh materials in pelvic organ prolapse repair.

Authors:  Prashanth Kanagarajah; Rajinikanth Ayyathurai; Christopher Gomez
Journal:  Curr Urol Rep       Date:  2012-06       Impact factor: 3.092

2.  Managing mesh exposure following vaginal prolapse repair: a decision analysis comparing conservative versus surgical treatment.

Authors:  Laura C Skoczylas; Jonathan P Shepherd; Kenneth J Smith; Jerry L Lowder
Journal:  Int Urogynecol J       Date:  2012-06-30       Impact factor: 2.894

3.  Trocarless system for mesh attachment in pelvic organ prolapse repair--1-year evaluation.

Authors:  Menachem Alcalay; Michel Cosson; Miron Livneh; Jean-Philippe Lucot; Peter Von Theobald
Journal:  Int Urogynecol J       Date:  2011-01-11       Impact factor: 2.894

4.  Comparison between Elevate anterior/apical system and Perigee system in pelvic organ prolapse surgery: clinical and sonographic outcomes.

Authors:  Tsia-Shu Lo; Nazura Bt Karim; Eileen Feliz M Cortes; Pei-Ying Wu; Yi-Hao Lin; Yiap Loong Tan
Journal:  Int Urogynecol J       Date:  2014-09-26       Impact factor: 2.894

5.  Impact of Prolift procedure on bladder function and symptoms in women with pelvic organ prolapse.

Authors:  Tsung-Hsien Su; Po-En Liu; Hui-Hsuan Lau; Wen-Chu Huang; Tzu-Yin Lin; Ching-Hung Hsieh
Journal:  Int Urogynecol J       Date:  2010-12-10       Impact factor: 2.894

6.  A prospective comparison of two commercial mesh kits in the management of anterior vaginal prolapse.

Authors: 
Journal:  Int Urogynecol J       Date:  2012-03       Impact factor: 2.894

7.  High risk of complications with a single incision pelvic floor repair kit: results of a retrospective case series.

Authors:  Stephen T Jeffery; Kendall Brouard
Journal:  Int Urogynecol J       Date:  2013-07-02       Impact factor: 2.894

8.  Predictors for persistent urodynamic stress incontinence following extensive pelvic reconstructive surgery with and without midurethral sling.

Authors:  Tsia-Shu Lo; Enie Akhtar Nawawi; Pei-Ying Wu; Nazura bt Karim; Ahlam Al-Kharabsheh
Journal:  Int Urogynecol J       Date:  2015-09-15       Impact factor: 2.894

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.