Literature DB >> 19386959

The use of gonad shielding in paediatric hip and pelvis radiographs.

S L Fawcett1, S J Barter.   

Abstract

The problem of inaccurate placement of gonad shields in children has been highlighted by several publications nationally and internationally over the past decade and more. Here, we review the literature and present the results of a regional audit designed to assess the use and accuracy of placement of gonad shields for hip and pelvis radiographs in children. 100 consecutive anteroposterior hip or pelvis radiographs in patients under the age of 16 years were reviewed in each of 9 centres. We also included the most recent and all previously available relevant radiographs. A total of 2405 radiographs were reviewed with regard to the presence of a shield and to the accuracy of any shield placement with respect to gonad protection and visualization of orthopaedic landmarks. It is recommended that gonad shields are used in all follow-up paediatric pelvis radiographs. Our results show they were only used in 70% of such cases. When placed, only 38% of all shields were considered to be positioned accurately. For cases where shielding was indicated, an accurately placed shield was present in just 26% of radiographs. Formal written departmental guidelines for shield use were only available in two centres. We conclude that clear guidelines need to be formulated which, together with shield redesign, improved training and audit, should increase effective gonad protection for children.

Entities:  

Mesh:

Year:  2009        PMID: 19386959     DOI: 10.1259/bjr/86609718

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  7 in total

1.  Female gonadal shielding with automatic exposure control increases radiation risks.

Authors:  Summer L Kaplan; Dennise Magill; Marc A Felice; Rui Xiao; Sayed Ali; Xiaowei Zhu
Journal:  Pediatr Radiol       Date:  2017-10-18

2.  More harm than good? The anatomy of misguided shielding of the ovaries.

Authors:  S L Fawcett; A C Gomez; S J Barter; M Ditchfield; P Set
Journal:  Br J Radiol       Date:  2011-11-17       Impact factor: 3.039

3.  Relative distribution of pertinent findings on portable neonatal abdominal radiographs: can we shield the gonads?

Authors:  Matthew Winfeld; Naomi Strubel; Lynne Pinkney; Shailee Lala; Sarah Milla; James Babb; Nancy Fefferman
Journal:  Pediatr Radiol       Date:  2013-05-02

4.  Gonad shielding in paediatric pelvic radiography: disadvantages prevail over benefit.

Authors:  Marij J Frantzen; Simon Robben; Alida A Postma; Johannes Zoetelief; Joachim E Wildberger; Gerrit J Kemerink
Journal:  Insights Imaging       Date:  2011-09-25

Review 5.  Managing the Pediatric Spine: Growth Assessment.

Authors:  Jason Pui Yin Cheung; Keith Dip-Kei Luk
Journal:  Asian Spine J       Date:  2017-10-11

6.  TO USE OR NOT USE PATIENT SHIELDING ON PREGNANT WOMEN UNDERGOING CT PULMONARY ANGIOGRAPHY: A PHANTOM STUDY.

Authors:  Dino Begano; Marcus Söderberg; Anetta Bolejko
Journal:  Radiat Prot Dosimetry       Date:  2020-07-24       Impact factor: 0.972

7.  Lower abdominal and pelvic radiation and testicular germ cell tumor risk.

Authors:  Kevin T Nead; Nandita Mitra; Benita Weathers; Louisa Pyle; Nnadozie Emechebe; Donna A Pucci; Linda A Jacobs; David J Vaughn; Katherine L Nathanson; Peter A Kanetsky
Journal:  PLoS One       Date:  2020-11-11       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.