Literature DB >> 19381392

Electrochemical genosensor for the rapid detection of GMO using loop-mediated isothermal amplification.

Minhaz Uddin Ahmed1, Masato Saito, M Mosharraf Hossain, S Ramachandara Rao, Satoshi Furui, Akihiro Hino, Yuzuru Takamura, Masahiro Takagi, Eiichi Tamiya.   

Abstract

In this study, we are reporting for the first time an efficient, accurate and inexpensive rapid detection system which employs the integration of isothermal amplification and subsequent analysis of unpurified amplicons by an electrochemical system. In our experiments, loop-mediated isothermal amplification (LAMP) with its higher efficiency than PCR was performed at a constant temperature (65 degrees C). Amplification products were combined with a redox active molecule Hoechst 33258 [H33258, 2'-(4-hydroxyphenyl)-5-(4-methyl-1-piperazinyl)-2,5'-bi(1H-benzimidazole)] and analyzed by a DNA stick (DS) which is integrated with a disposable electrochemical printed (DEP) chip using linear sweep voltammetry (LSV). The DNA minor groove binding of the H33258 molecule causes a significant drop in the peak current intensity of the H33258 oxidation. The phenomenon of DNA binding induced by H33258, in addition to changes in the anodic current peak, was used to detect maize CBH 351 variety (StarLink). Since laborious probe immobilization was not required, and amplification and detection were performed on a single device, our biosensor eliminates potential cross-contamination. We believe that this type of sensor will have an unprecedented impact for environmental protection.

Entities:  

Mesh:

Year:  2009        PMID: 19381392     DOI: 10.1039/b812569d

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  5 in total

1.  Emerging Loop-Mediated Isothermal Amplification-Based Microchip and Microdevice Technologies for Nucleic Acid Detection.

Authors:  Mohammadali Safavieh; Manoj K Kanakasabapathy; Farhang Tarlan; Minhaz U Ahmed; Mohammed Zourob; Waseem Asghar; Hadi Shafiee
Journal:  ACS Biomater Sci Eng       Date:  2016-01-21

2.  Rapid porcine detection in gelatin-based highly processed products using loop mediated isothermal amplification.

Authors:  Nor Asmara Tasrip; Mohd Nasir Mohd Desa; Nur Fadhilah Khairil Mokhtar; Nurhayatie Sajali; Amalia Mohd Hashim; Md Eaqub Ali; Cheah Yoke Kqueen
Journal:  J Food Sci Technol       Date:  2021-01-06       Impact factor: 2.701

3.  Towards a versatile and economic Chagas Disease point-of-care testing system, by integrating loop-mediated isothermal amplification and contactless/label-free conductivity detection.

Authors:  Federico Figueredo; Fabiana Stolowicz; Adrián Vojnov; Wendell K T Coltro; Luciana Larocca; Carolina Carrillo; Eduardo Cortón
Journal:  PLoS Negl Trop Dis       Date:  2021-05-14

Review 4.  Trends and advances in food analysis by real-time polymerase chain reaction.

Authors:  Nur Thaqifah Salihah; Mohammad Mosharraf Hossain; Hamadah Lubis; Minhaz Uddin Ahmed
Journal:  J Food Sci Technol       Date:  2016-05-05       Impact factor: 2.701

5.  Establishment and application of a loop-mediated isothermal amplification (LAMP) system for detection of cry1Ac transgenic sugarcane.

Authors:  Dinggang Zhou; Jinlong Guo; Liping Xu; Shiwu Gao; Qingliang Lin; Qibin Wu; Luguang Wu; Youxiong Que
Journal:  Sci Rep       Date:  2014-05-09       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.