A simple approach to using an amorphous silicon EPID to verify IMRT planar dose maps.

Christopher Lee1, Fred Menk, Patrick Cadman, Peter B Greer.   

Abstract

A simplified method of verifying intensity modulated radiation therapy (IMRT) fields using a Varian aS500 amorphous silicon electronic portal imaging device (EPID) is demonstrated. Unlike previous approaches, it does not involve time consuming or complicated analytical processing of the data. The central axis pixel response of the EPID, as well as the profile characteristics obtained from images acquired with a 6 MV photon beam, was examined as a function of field size. Ion chamber measurements at various depths in a water phantom were then collected and it was found that at a specific depth d(ref), the dose response and profile characteristics closely matched the results of the EPID analysis. The only manipulation required to be performed on the EPID images was the multiplication of a matrix of off axis ratio values to remove the effect of the flood field calibration. Similarly, d(ref) was found for 18 MV. Planar dose maps at d(ref) in a water phantom for a bar pattern, a strip pattern, and 14 clinical IMRT fields from two patient cases each being from a separate anatomical region, i.e., head and neck as well as the pelvis, for both energies were generated by the Pinnacle planning system (V7.4). EPID images of these fields were acquired and converted to planar dose maps and compared directly with the Pinnacle planar dose maps. Radiographic film dosimetry and a MapCHECK dosimetry device (Sun Nuclear Corporation, Melbourne, FL) were used as an independent verification of the dose distribution. Gamma analysis of the EPID, film, and Pinnacle planar dose maps generated for the clinical IMRT fields showed that approximately 97% of all points passed using a 3% dose/3 mm DTA tolerance test. Based on the range of fields studied, the author's results appear to justify using this approach as a method to verify dose distributions calculated on a treatment planning system, including complex intensity modulated fields.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19378759     DOI: 10.1118/1.3075817

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Verification of MLC based real-time tumor tracking using an electronic portal imaging device.

Authors:  Sarah Han-Oh; Byong Yong Yi; Fritz Lerma; Barry L Berman; Minzhi Gui; Cedric Yu
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Exit fluence analysis using portal dosimetry in volumetric modulated arc therapy.

Authors:  Prabakar Sukumar; Sriram Padmanaban; Dhanabalan Rajasekaran; Muniyappan Kannan; Vivekanandan Nagarajan
Journal:  Rep Pract Oncol Radiother       Date:  2012-07-15

3.  Simple proposal for dosimetry with an Elekta iViewGT™ electronic portal imaging device (EPID) using commercial software modules.

Authors:  Janett Liebich; Jörg Licher; Christian Scherf; Eugen Kara; Nadine Koch; Claus Rödel; Ulla Ramm
Journal:  Strahlenther Onkol       Date:  2011-04-26       Impact factor: 3.621

4.  An empirical calibration method for an a-Si portal imaging device: applications in pretreatment verification of IMRT.

Authors:  L Conte; C Mordacchini; L Pozzi; C Vite
Journal:  Radiol Med       Date:  2012-03-19       Impact factor: 3.469

5.  Evaluation of a fast method of EPID-based dosimetry for intensity-modulated radiation therapy.

Authors:  Benjamin E Nelms; Karl H Rasmussen; Wolfgang A Tome
Journal:  J Appl Clin Med Phys       Date:  2010-04-19       Impact factor: 2.102

6.  Portal dosimetry for pretreatment verification of IMRT plan: a comparison with 2D ion chamber array.

Authors:  Dayananda Shamurailatpam Sharma; Vaibav Mhatre; Malhotra Heigrujam; Kaustav Talapatra; Suman Mallik
Journal:  J Appl Clin Med Phys       Date:  2010-08-19       Impact factor: 2.102

7.  Intensity-modulated radiation therapy dose verification using fluence and portal imaging device.

Authors:  Iori Sumida; Hajime Yamaguchi; Indra J Das; Hisao Kizaki; Keiko Aboshi; Mari Tsujii; Yuji Yamada; Osamu Suzuki; Yuji Seo; Fumiaki Isohashi; Kazuhiko Ogawa
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

8.  EPID-based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams.

Authors:  Narges Miri; Peter Keller; Benjamin J Zwan; Peter Greer
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

9.  Two-dimensional in vivo dose verification using portal imaging and correlation ratios.

Authors:  Stefano Peca; Derek W Brown
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.