Literature DB >> 19376348

On-line sequential injection dispersive liquid-liquid microextraction system for flame atomic absorption spectrometric determination of copper and lead in water samples.

Aristidis N Anthemidis1, Kallirroy-Ioanna G Ioannou.   

Abstract

A simple, sensitive and powerful on-line sequential injection (SI) dispersive liquid-liquid microextraction (DLLME) system was developed as an alternative approach for on-line metal preconcentration and separation, using extraction solvent at microlitre volume. The potentials of this novel schema, coupled to flame atomic absorption spectrometry (FAAS), were demonstrated for trace copper and lead determination in water samples. The stream of methanol (disperser solvent) containing 2.0% (v/v) xylene (extraction solvent) and 0.3% (m/v) ammonium diethyldithiophosphate (chelating agent) was merged on-line with the stream of sample (aqueous phase), resulting a cloudy mixture, which was consisted of fine droplets of the extraction solvent dispersed entirely into the aqueous phase. By this continuous process, metal chelating complexes were formed and extracted into the fine droplets of the extraction solvent. The hydrophobic droplets of organic phase were retained into a microcolumn packed with PTFE-turnings. A portion of 300 microL isobutylmethylketone was used for quantitative elution of the analytes, which transported directly to the nebulizer of FAAS. All the critical parameters of the system such as type of extraction solvent, flow-rate of disperser and sample, extraction time as well as the chemical parameters were studied. Under the optimum conditions the enhancement factor for copper and lead was 560 and 265, respectively. For copper, the detection limit and the precision (R.S.D.) were 0.04 microg L(-1) and 2.1% at 2.0 microg L(-1) Cu(II), respectively, while for lead were 0.54 microg L(-1) and 1.9% at 30.0 microg L(-1) Pb(II), respectively. The developed method was evaluated by analyzing certified reference material and applied successfully to the analysis of environmental water samples.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19376348     DOI: 10.1016/j.talanta.2009.03.005

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

Review 1.  Green Extraction Techniques as Advanced Sample Preparation Approaches in Biological, Food, and Environmental Matrices: A Review.

Authors:  José S Câmara; Rosa Perestrelo; Cristina V Berenguer; Carolina F P Andrade; Telma M Gomes; Basit Olayanju; Abuzar Kabir; Cristina M R Rocha; José António Teixeira; Jorge A M Pereira
Journal:  Molecules       Date:  2022-05-06       Impact factor: 4.927

Review 2.  Applications of Metal-Organic Frameworks in Food Sample Preparation.

Authors:  Natalia Manousi; George A Zachariadis; Eleni A Deliyanni; Victoria F Samanidou
Journal:  Molecules       Date:  2018-11-06       Impact factor: 4.411

3.  Deep eutectic solvents as a new kind of dispersive solvent for dispersive liquid-liquid microextraction.

Authors:  Andrey Shishov; Natalia Volodina; Daria Nechaeva; Svetlana Gagarinova; Andrey Bulatov
Journal:  RSC Adv       Date:  2018-11-14       Impact factor: 3.361

4.  Pseudo-stir bar hollow fiber solid/liquid phase microextraction combined with anodic stripping voltammetry for determination of lead and cadmium in water samples.

Authors:  Zarrin Es'haghi; Hasan Ali Hoseini; Saeed Mohammadi-Nokhandani; Javad Ebrahimi
Journal:  J Adv Res       Date:  2013-11-20       Impact factor: 10.479

  4 in total