Literature DB >> 19376251

High-throughput micro-computed tomography imaging as a method to evaluate rat and rabbit fetal skeletal abnormalities for developmental toxicity studies.

Christopher T Winkelmann1, L David Wise.   

Abstract

INTRODUCTION: Fetal skeletal assessments are routinely conducted as a part of preclinical safety studies to support the development of novel therapeutic agents. Alizarin red staining with visual inspection of fetal skeletons is the gold standard in evaluating skeletons for the presence of developmental abnormalities. X-ray based micro-computed tomography (micro-CT) imaging has been used to evaluate small skeletal structures, both in vivo and ex vivo. Recent technological advances have reduced micro-CT image acquisition time making this technology practical for routine fetal skeletal evaluations. Herein we report on the use of micro-CT imaging as a method to perform high-throughput assessment of fetal skeletons.
METHODS: Micro-CT imaging of rat and rabbit fetal skeletons was conducted under a variety of conditions, including, in vivo, contrast-enhanced in vivo, and ex vivo. To increase throughput, micro-CT imaging was employed using custom designed polystyrene foam fetal holders to image entire litters of ex vivo fetuses. After micro-CT imaging, fetuses were routinely stained with alizarin red to compare micro-CT imaging results with traditional alizarin red staining.
RESULTS: Fetal skeletons could be visualized using in vivo micro-CT imaging; however, due to crowding, specific identification of individual fetuses was deemed not practical. Administration of a routine contrast agent to pregnant females highlighted maternal vascular structures including the placenta, but unfortunately, did not cross the placenta and did not highlight any fetal soft tissue structures. Ex vivo fetal imaging provided the best image quality of fetal skeletons and allowed for specific fetal identification. The fetal holders allowed for micro-CT imaging of approximately 400 rat fetuses or approximately 140 rabbit fetuses per hour. Micro-CT image skeletal findings and alizarin red findings were comparable. The very few discrepancies between the two methods involved the smallest skeletal elements with minimal ossification. DISCUSSION: In conclusion, micro-CT ex vivo imaging can provide a reliable high-throughput method to assess fetal skeletal abnormalities for developmental toxicity studies.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19376251     DOI: 10.1016/j.vascn.2009.03.004

Source DB:  PubMed          Journal:  J Pharmacol Toxicol Methods        ISSN: 1056-8719            Impact factor:   1.950


  11 in total

Review 1.  3-dimensional imaging modalities for phenotyping genetically engineered mice.

Authors:  K A Powell; D Wilson
Journal:  Vet Pathol       Date:  2011-12-06       Impact factor: 2.221

2.  Functional phenotyping of the maternal albumin turnover in the mouse placenta by dynamic contrast-enhanced MRI.

Authors:  Vicki Plaks; Stav Sapoznik; Elina Berkovitz; Rebecca Haffner-Krausz; Nava Dekel; Alon Harmelin; Michal Neeman
Journal:  Mol Imaging Biol       Date:  2011-06       Impact factor: 3.488

3.  Quantitative three-dimensional imaging of live avian embryonic morphogenesis via micro-computed tomography.

Authors:  Alyssa L Henning; Michael X Jiang; Huseyin C Yalcin; Jonathan T Butcher
Journal:  Dev Dyn       Date:  2011-08       Impact factor: 3.780

4.  PET/CT imaging reveals unrivaled placental avidity for glucose compared to other tissues.

Authors:  A B Sawatzke; A W Norris; F Spyropoulos; S A Walsh; M R Acevedo; S Hu; J Yao; C Wang; J J Sunderland; L L Boles Ponto
Journal:  Placenta       Date:  2014-12-23       Impact factor: 3.481

5.  Continuing education course #1: non-invasive imaging as a problem-solving tool and translational biomarker strategy in toxicologic pathology.

Authors:  Richard A Peterson; Kathy L Gabrielson; G Allan Johnson; Martin G Pomper; Robert W Coatney; Christopher T Winkelmann
Journal:  Toxicol Pathol       Date:  2010-12-08       Impact factor: 1.902

6.  Imaging technologies for preclinical models of bone and joint disorders.

Authors:  Jordi L Tremoleda; Magdy Khalil; Luke L Gompels; Marzena Wylezinska-Arridge; Tonia Vincent; Willy Gsell
Journal:  EJNMMI Res       Date:  2011-07-29       Impact factor: 3.138

7.  Monitoring brain development of chick embryos in vivo using 3.0 T MRI: subdivision volume change and preliminary structural quantification using DTI.

Authors:  Zien Zhou; Zengai Chen; Jiehui Shan; Weiwei Ma; Lei Li; Jinyan Zu; Jianrong Xu
Journal:  BMC Dev Biol       Date:  2015-07-25       Impact factor: 1.978

8.  Value of micro-CT for monitoring spinal microvascular changes after chronic spinal cord compression.

Authors:  Hou-Qing Long; Wen-Han Xie; Wen-Li Chen; Wen-Lin Xie; Jing-Hui Xu; Yong Hu
Journal:  Int J Mol Sci       Date:  2014-07-07       Impact factor: 5.923

9.  Bone microarchitectural parameters can detect oxytocin induced changes prior to bone density on mitigating bone deterioration in rabbit osteoporosis model using micro-CT.

Authors:  Yuyou Qiu; Cuisong Tang; Mario Serrano-Sosa; Jian Hu; Jingqi Zhu; Guangyu Tang; Chuan Huang; Mingqian Huang
Journal:  BMC Musculoskelet Disord       Date:  2019-11-23       Impact factor: 2.362

10.  High-throughput microCT scanning of small specimens: preparation, packing, parameters and post-processing.

Authors:  Christy A Hipsley; Rocio Aguilar; Jay R Black; Scott A Hocknull
Journal:  Sci Rep       Date:  2020-08-17       Impact factor: 4.379

View more