Literature DB >> 19372335

Noninvasive assessment of cardiac index in healthy volunteers: a comparison between thoracic impedance cardiography and Doppler echocardiography.

Jean-Luc Fellahi1, Vincent Caille, Cyril Charron, Pierre-Hervé Deschamps-Berger, Antoine Vieillard-Baron.   

Abstract

BACKGROUND: Thoracic bioimpedance cardiography (ICG) has been proposed as a noninvasive, continuous, operator-independent, and cost-effective method for cardiac output monitoring. In the present study, we compared cardiac index (CI) measurements with ICG (Niccomo device) and transthoracic Doppler echocardiography in resting healthy volunteers undergoing hemodynamic load challenge.
METHODS: Twenty-five healthy volunteers (7 men and 18 women, mean age 36 +/- 6 yr, body surface area 1.75 +/- 0.17 m(2)) were investigated during three experimental conditions: baseline, positive end-expiratory pressure + 10 cm H(2)O and lower body positive pressure by means of medical antishock trousers inflated to 30 cm H(2)O in the abdominal compartment.
RESULTS: ICG signal quality was >89% over all sets of measurements. A weak but significant relationship was observed between CI(TTE) and CI(ICG) (r = 0.36; P = 0.002). Agreement between both techniques was 0.94 L x min(-1) x m(-2) (95% CI: 0.77-1.11), limits of agreement were -0.47 to 2.35 L x min(-1) x m(-2), and percentage error was 53%. No statistically significant relationships were found between percent changes in CI(TTE) and CI(ICG) after applications of positive end-expiratory pressure + 10 cm H(2)O (r = 0.21; P = 0.31) and medical antishock trousers (r = 0.22; P = 0.30).
CONCLUSIONS: Poor correlation and lack of agreement between absolute values of CI measured by ICG and transthoracic Doppler echocardiography were found in resting healthy volunteers. The Niccomo device was also unreliable for monitoring changes in CI during hemodynamic load challenge.

Entities:  

Mesh:

Year:  2009        PMID: 19372335     DOI: 10.1213/ane.0b013e31819cd97e

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  13 in total

Review 1.  [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

Authors:  G Pestel; K Fukui; M Higashi; I Schmidtmann; C Werner
Journal:  Anaesthesist       Date:  2018-06       Impact factor: 1.041

2.  Cardiac parameters in children recovered from acute illness as measured by electrical cardiometry and comparisons to the literature.

Authors:  Jackson Wong; Michael S D Agus; Garry M Steil
Journal:  J Clin Monit Comput       Date:  2012-10-06       Impact factor: 2.502

3.  Beat-to-beat estimation of stroke volume using impedance cardiography and artificial neural network.

Authors:  S M M Naidu; Prem C Pandey; Uttam R Bagal; Suhas P Hardas
Journal:  Med Biol Eng Comput       Date:  2017-11-18       Impact factor: 2.602

4.  Measurement of cardiac output in children by bioreactance.

Authors:  Yolanda Ballestero; Jesús López-Herce; Javier Urbano; Maria José Solana; Marta Botrán; Jose M Bellón; Angel Carrillo
Journal:  Pediatr Cardiol       Date:  2011-02-13       Impact factor: 1.655

5.  Can endotracheal bioimpedance cardiography assess hemodynamic response to passive leg raising following cardiac surgery?

Authors:  Jean-Luc Fellahi; Marc-Olivier Fischer; Audrey Dalbera; Massimo Massetti; Jean-Louis Gérard; Jean-Luc Hanouz
Journal:  Ann Intensive Care       Date:  2012-07-11       Impact factor: 6.925

6.  Haemodynamic changes in the superior mesenteric artery induced by acupuncture stimulation on the lower limbs.

Authors:  Masashi Watanabe; Shin Takayama; Yoshiko Yamamoto; Satoru Nagase; Takashi Seki; Nobuo Yaegashi
Journal:  Evid Based Complement Alternat Med       Date:  2012-05-23       Impact factor: 2.629

7.  Validation of thoracic impedance cardiography by echocardiography in healthy late pregnancy.

Authors:  Jordan P R McIntyre; Kevin M Ellyett; Edwin A Mitchell; Gina M Quill; John Md Thompson; Alistair W Stewart; Robert N Doughty; Peter R Stone
Journal:  BMC Pregnancy Childbirth       Date:  2015-03-28       Impact factor: 3.007

8.  Non-invasive stroke volume estimation by transthoracic electrical bioimpedance versus Doppler echocardiography in healthy volunteers.

Authors:  Mirae Harford; Samuel H Clark; Jodie F Smythe; Stephen Gerry; Mauricio Villarroel; Joao Jorge; Sitthichok Chaichulee; Lionel Tarassenko; Duncan Young; Peter Watkinson
Journal:  J Med Eng Technol       Date:  2019-04-15

9.  Comparing impedance cardiography and echocardiography in the assessment of reduced left ventricular systolic function.

Authors:  Elzbieta Kaszuba; Sergej Scheel; Håkan Odeberg; Anders Halling
Journal:  BMC Res Notes       Date:  2013-03-26

10.  Hemodynamic changes in the brachial artery induced by acupuncture stimulation on the lower limbs: a single-blind randomized controlled trial.

Authors:  Masashi Watanabe; Shin Takayama; Atsushi Hirano; Takashi Seki; Nobuo Yaegashi
Journal:  Evid Based Complement Alternat Med       Date:  2012-11-25       Impact factor: 2.629

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.