Literature DB >> 19368987

Treatment delivery time optimization of respiratory gated radiation therapy by application of audio-visual feedback.

Nadine Linthout1, Samuel Bral, Iwein Van de Vondel, Dirk Verellen, Koen Tournel, Thierry Gevaert, Michael Duchateau, Truus Reynders, Guy Storme.   

Abstract

PURPOSE: The feasibility to use visually guided voluntary breath-hold with and without audio assistance to reduce the total treatment time was evaluated.
MATERIALS AND METHODS: Patients referred for gated SBRT received hypofractionation schedules for lung or liver treatments. The patients were treated with the Novalis system (BrainLAB AG, Feldkirchen, Germany) and IGRT was performed with ExacTrac5.0/NovalisBody allowing gated irradiation. Video glasses, used for visual feedback to guide voluntary breath-hold, allowed additional audio assistance during treatment. The technique was applied for 25 patients of whom 9 were treated in free breathing, 7 had only visual feedback and another 9 had both audio and visual feedback.
RESULTS: The delivery time of gated treatment during free breathing had an average value of 1.7 min/100 MU (SD 0.6 min/100 MU). The introduction of visual feedback reduced the average delivery time to 1.4 min/100 MU (SD 0.4 min/100 MU). The treatments with additional audio assistance indicated a significant reduction (p=0.004) of the average delivery time to 0.9 min/100 MU (SD 0.2 min/100 MU).
CONCLUSION: The introduction of visually guided voluntary breath-hold with audio assistance led to treatment times for gated radiation therapy approaching conformal beam delivery times, which made gated treatments applicable in conventional treatment time slots.

Entities:  

Mesh:

Year:  2009        PMID: 19368987     DOI: 10.1016/j.radonc.2009.03.019

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  12 in total

1.  Dynamic gating window for compensation of baseline shift in respiratory-gated radiation therapy.

Authors:  Eric W Pepin; Huanmei Wu; Hiroki Shirato
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

2.  Respiratory motion management using audio-visual biofeedback for respiratory-gated radiotherapy of synchrotron-based pulsed heavy-ion beam delivery.

Authors:  Pengbo He; Qiang Li; Xinguo Liu; Zhongying Dai; Ting Zhao; Tingyan Fu; Guosheng Shen; Yuanyuan Ma; Qiyan Huang; Yuanlin Yan
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

Review 3.  The impact of modern radiotherapy on long-term cardiac sequelae in breast cancer survivor: a focus on deep inspiration breath-hold (DIBH) technique.

Authors:  V Salvestrini; G C Iorio; P Borghetti; F De Felice; C Greco; V Nardone; A Fiorentino; F Gregucci; I Desideri
Journal:  J Cancer Res Clin Oncol       Date:  2021-12-01       Impact factor: 4.553

4.  Performance evaluation of a visual guidance patient-controlled respiratory gating system for respiratory-gated magnetic-resonance image-guided radiation therapy.

Authors:  Hyung Jin Choun; Jung-In Kim; Chang Heon Choi; Seongmoon Jung; Hyeongmin Jin; Hong-Gyun Wu; Eui Kyu Chie; Jong Min Park
Journal:  Phys Eng Sci Med       Date:  2022-06-20

5.  Technical Note: Evaluation of audiovisual biofeedback smartphone application for respiratory monitoring in radiation oncology.

Authors:  Dante P I Capaldi; Tomi F Nano; Hao Zhang; Lawrie B Skinner; Lei Xing
Journal:  Med Phys       Date:  2020-10-10       Impact factor: 4.071

6.  Dose compensation based on biological effectiveness due to interruption time for photon radiation therapy.

Authors:  Daisuke Kawahara; Hisashi Nakano; Akito Saito; Shuichi Ozawa; Yasushi Nagata
Journal:  Br J Radiol       Date:  2020-05-07       Impact factor: 3.039

7.  Implementation of an in-house visual feedback system for motion management during radiation therapy.

Authors:  Vi Nhan V Nguyen; David C Ellerbusch; Ashley J Cetnar; Joshua A James; Brian Wang
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

8.  Development and clinical evaluation of a simple optical method to detect and measure patient external motion.

Authors:  Benigno Barbés; Juan Diego Azcona; Elena Prieto; José Manuel de Foronda; Marina García; Javier Burguete
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

9.  Assessment of tumor motion reproducibility with audio-visual coaching through successive 4D CT sessions.

Authors:  Samuel Goossens; Frédéric Senny; John A Lee; Guillaume Janssens; Xavier Geets
Journal:  J Appl Clin Med Phys       Date:  2014-01-04       Impact factor: 2.102

10.  Amplitude gating for a coached breathing approach in respiratory gated 10 MV flattening filter-free VMAT delivery.

Authors:  Francis Viel; Richard Lee; Ermias Gete; Cheryl Duzenli
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.