Michael Smith1, Yvonne M Buys, Graham E Trope. 1. Department of Ophthalmology and Visual Sciences, Toronto Western Hospital, University of Toronto, Ontario, Canada. mic.smith@utoronto.ca
Abstract
PURPOSE: To examine the results of same-eye second Ahmed glaucoma drainage device (GDD) insertion in eyes with refractory glaucoma despite previous Ahmed GDD insertion and maximal tolerated medical therapy. METHODS: Noncomparative retrospective case series. RESULTS: Twenty-one patients who had undergone 2 GDD surgeries in the same eye were identified. Following chart review, 19 patients had follow-up of at least 1 year and were included in the analysis. All surgeries involved Ahmed valves. The mean drop in intraocular pressure (IOP) at 12 months and at final follow-up was 8 (43%) and 7.9 mm Hg (42%), respectively. The mean number of glaucoma medications used postoperatively (2.4 at 12 mo and 2.6 at final follow-up) was significantly less than preoperatively (4.1). Although the mean visual acuity was poorer postoperatively, this did not reach statistical significance. Sixteen of the 19 patients (84.2%) were defined as complete or partial success, as they achieved IOP of >/=5 and </=21 mm Hg and >/=20% decrease on preoperative IOP with or without glaucoma drops. Three patients were considered complete failures at 12 months and final follow-up. There were no significant intraoperative complications. One patient (5.3%) required anterior chamber reformation on day 1 postoperatively. One patient (5.3%) suffered a decrease in vision from 20/70 preoperatively to counting fingers postoperatively owing to corneal decompensation. CONCLUSIONS: Second Ahmed GDD surgery seems to be a safe and effective option when IOP remains uncontrolled despite previous GDD implantation.
PURPOSE: To examine the results of same-eye second Ahmed glaucoma drainage device (GDD) insertion in eyes with refractory glaucoma despite previous Ahmed GDD insertion and maximal tolerated medical therapy. METHODS: Noncomparative retrospective case series. RESULTS: Twenty-one patients who had undergone 2 GDD surgeries in the same eye were identified. Following chart review, 19 patients had follow-up of at least 1 year and were included in the analysis. All surgeries involved Ahmed valves. The mean drop in intraocular pressure (IOP) at 12 months and at final follow-up was 8 (43%) and 7.9 mm Hg (42%), respectively. The mean number of glaucoma medications used postoperatively (2.4 at 12 mo and 2.6 at final follow-up) was significantly less than preoperatively (4.1). Although the mean visual acuity was poorer postoperatively, this did not reach statistical significance. Sixteen of the 19 patients (84.2%) were defined as complete or partial success, as they achieved IOP of >/=5 and </=21 mm Hg and >/=20% decrease on preoperative IOP with or without glaucoma drops. Three patients were considered complete failures at 12 months and final follow-up. There were no significant intraoperative complications. One patient (5.3%) required anterior chamber reformation on day 1 postoperatively. One patient (5.3%) suffered a decrease in vision from 20/70 preoperatively to counting fingers postoperatively owing to corneal decompensation. CONCLUSIONS: Second Ahmed GDD surgery seems to be a safe and effective option when IOP remains uncontrolled despite previous GDD implantation.
Authors: Brian A Francis; Rodrigo A B Fernandes; Handan Akil; Vikas Chopra; Bruno Diniz; James Tan; Alex Huang Journal: Graefes Arch Clin Exp Ophthalmol Date: 2017-02-07 Impact factor: 3.117
Authors: Chiara Posarelli; Mario Damiano Toro; Robert Rejdak; Tomasz Żarnowski; Dorota Pożarowska; Antonio Longo; Mario Miccoli; Marco Nardi; Michele Figus Journal: J Clin Med Date: 2020-06-29 Impact factor: 4.241
Authors: Robert M Feldman; Alice Z Chuang; Steve L Mansberger; Angelo P Tanna; Lauren S Blieden; Nicholas P Bell; Ronald L Gross; Louis R Pasquale; David S Greenfield; Jeffrey M Liebmann; Robert N Weinreb Journal: J Glaucoma Date: 2022-07-21 Impact factor: 2.290