Literature DB >> 1936234

A flow interruption device for measurement of airway resistance.

P J Chowienczyk1, C P Lawson, S Lane, R Johnson, N Wilson, M Silverman, G M Cochrane.   

Abstract

Unlike conventional methods, the interrupter method for measuring airway resistance is non-invasive and requires minimal patient co-operation. It can therefore be applied in critically ill patients, acute asthmatics, neonates, pre-school children, geriatric patients and unconscious patients. The method is based on transient interruption of airflow at the mouth for a brief period during which alveolar pressure equilibrates with mouth pressure. Measurement of mouth pressure is used to estimate alveolar pressure prior to interruption and the ratio of this to flow prior to interruption gives airway resistance. Using the interrupter method we have developed a portable device for measuring airway resistance which is simple to use and gives a direct instantaneous reading. Measurements of airway resistance obtained using the new device were compared with those obtained using conventional body plethysmograph methods in 43 adult patients. A close correlation was seen (r = 0.86). The two methods appear equally sensitive in detecting changes in airway resistance following bronchodilator therapy. The device has been used successfully in pre-school children unable to co-operate with conventional methods.

Entities:  

Mesh:

Year:  1991        PMID: 1936234

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  4 in total

1.  Airway resistance measured by the interrupter technique: normative data for 2-10 year olds of three ethnicities.

Authors:  S A McKenzie; E Chan; I Dundas; P D Bridge; C S Pao; M Mylonopoulou; M J R Healy
Journal:  Arch Dis Child       Date:  2002-09       Impact factor: 3.791

2.  Effects of the menstrual cycle on expiratory resistance during whole body exercise in females.

Authors:  Alethea J Anderson; Mark A Babcock
Journal:  J Sports Sci Med       Date:  2008-12-01       Impact factor: 2.988

3.  Reference values of interrupter respiratory resistance in healthy preschool white children.

Authors:  E Lombardi; P D Sly; G Concutelli; E Novembre; G Veneruso; G Frongia; R Bernardini; A Vierucci
Journal:  Thorax       Date:  2001-09       Impact factor: 9.139

4.  Noninvasive assessment of asthma severity using pulse oximeter plethysmograph estimate of pulsus paradoxus physiology.

Authors:  Donald H Arnold; Cathy A Jenkins; Tina V Hartert
Journal:  BMC Pulm Med       Date:  2010-03-29       Impact factor: 3.317