Literature DB >> 19352659

Treatment of posterior pelvic ring injuries with minimally invasive percutaneous plate osteosynthesis.

Tang Hao1, Yang Changwei, Zhang Qiulin.   

Abstract

From January 2004 to July 2007, 21 patients with injuries at the posterior pelvic ring were treated with locking compression plate osteosynthesis through a minimally invasive approach and followed up for a mean of 12.2 months. Preoperative and postoperative radiography was conducted to assess the reduction and union. The mean operation time was 60 minutes (range: 40-80). Intraoperative blood loss was 50-150 ml. All patients achieved union at the final follow-up. The overall radiological results were excellent or good in 17 patients (85%). The functional outcome was excellent or good in 18 patients (90%). There was no iatrogenic nerve injury, deep infection or failure of fixation. We believe that fixation with a locking compression plate is an effective method for the treatment of injuries of the posterior pelvic ring in view of its convenience, minimal traumatic invasion and lower morbidity.

Entities:  

Mesh:

Year:  2009        PMID: 19352659      PMCID: PMC2899098          DOI: 10.1007/s00264-009-0756-7

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  25 in total

1.  Safe placement of S1 and S2 iliosacral screws: the "vestibule" concept.

Authors:  D A Carlson; D K Scheid; D C Maar; J R Baele; D M Kaehr
Journal:  J Orthop Trauma       Date:  2000-05       Impact factor: 2.512

2.  Anatomy of the posterior iliac crest as a reference to sacral bar insertion.

Authors:  Doğan Atlíhan; Murat Bozkurt; Sacit Turanlí; Metin Doğan; Ibrahim Tekdemir; Alaittin Elhan
Journal:  Clin Orthop Relat Res       Date:  2004-01       Impact factor: 4.176

3.  Stereotactic CT-guided percutaneous stabilization of posterior pelvic ring fractures: a preclinical cadaver study.

Authors:  Reto J Bale; Peter Kovacs; Bahman Dolati; Christoph Hinterleithner; Ralf E Rosenberger
Journal:  J Vasc Interv Radiol       Date:  2008-06-02       Impact factor: 3.464

4.  Sacral fractures: an important problem. Retrospective analysis of 236 cases.

Authors:  F Denis; S Davis; T Comfort
Journal:  Clin Orthop Relat Res       Date:  1988-02       Impact factor: 4.176

5.  Sacral fractures with neurological injury: is early decompression beneficial?

Authors:  B A Zelle; G S Gruen; T Hunt; S R Speth
Journal:  Int Orthop       Date:  2004-04-22       Impact factor: 3.075

Review 6.  Biomechanics of locked plates and screws.

Authors:  Kenneth A Egol; Erik N Kubiak; Eric Fulkerson; Frederick J Kummer; Kenneth J Koval
Journal:  J Orthop Trauma       Date:  2004-09       Impact factor: 2.512

7.  [Triangular vertebropelvine stabilisation of unstable posterior pelvic ring fractures].

Authors:  A H Tiemann; C Schmidt; C Josten
Journal:  Zentralbl Chir       Date:  2003-03       Impact factor: 0.942

8.  Treatment of unstable pelvic fractures: use of a transiliac sacral rod for posterior lesions and an external fixator for anterior lesions.

Authors:  Fang-Yao Chiu; Tien-Yow Chuang; Wai-Hee Lo
Journal:  J Trauma       Date:  2004-07

9.  Early open reduction and internal fixation of the disrupted pelvic ring.

Authors:  A Goldstein; T Phillips; S J Sclafani; T Scalea; A Duncan; J Goldstein; T Panetta; G Shaftan
Journal:  J Trauma       Date:  1986-04

10.  Biomechanical comparison of posterior pelvic ring fixation.

Authors:  Kent Yinger; Jason Scalise; Steven A Olson; Brian K Bay; Christopher G Finkemeier
Journal:  J Orthop Trauma       Date:  2003-08       Impact factor: 2.512

View more
  14 in total

1.  Standalone percutaneous transiliac plating of vertically unstable sacral fractures: outcomes, complications, and recommendations.

Authors:  Mostafa A Ayoub; Hossam M Gad; Osama A Seleem
Journal:  Eur Spine J       Date:  2015-04-22       Impact factor: 3.134

2.  Biomechanical comparison of three types of internal fixation in a type C zone II pelvic fracture model.

Authors:  Tao Wu; Wei Chen; Xu Li; Qi Zhang; Hong-Zhi Lv; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

3.  Biomechanical analysis of a transiliac internal fixator.

Authors:  Thomas Dienstknecht; Arne Berner; Andreas Lenich; Johannes Zellner; Michael Mueller; Michael Nerlich; Bernd Fuechtmeier
Journal:  Int Orthop       Date:  2011-04-08       Impact factor: 3.075

4.  Midterm radiologic and functional outcomes of minimally-invasive fixation of unstable pelvic fractures using anterior internal fixator(INFIX) and percutaneous iliosacral screws.

Authors:  Ajoy Prasad Shetty; Aju Bosco; Ramesh Perumal; Jeyaramaraju Dheenadhayalan; Shanmuganathan Rajasekaran
Journal:  J Clin Orthop Trauma       Date:  2017-06-10

5.  Therapeutic effects of minimally invasive adjustable and locking compression plate for unstable pelvic fractures via posterior approach.

Authors:  Tao Wu; Wei Chen; Qi Zhang; Xu Li; Hong-Zhi Lv; Guang Yang; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-01-15

6.  A minimally invasive stabilizing system for dorsal pelvic ring injuries.

Authors:  Thomas Dienstknecht; Arne Berner; Andreas Lenich; Michael Nerlich; Bernd Fuechtmeier
Journal:  Clin Orthop Relat Res       Date:  2011-05-24       Impact factor: 4.176

Review 7.  Vertical shear pelvic injury: evaluation, management, and fixation strategies.

Authors:  Laura Blum; Mark E Hake; Ryan Charles; Todd Conlan; David Rojas; Murphy Trey Martin; Cyril Mauffrey
Journal:  Int Orthop       Date:  2018-03-26       Impact factor: 3.075

8.  Minimally invasive treatment for pubic ramus fractures combined with a sacroiliac joint complex injury.

Authors:  Xiaowei Yu; Mingjie Tang; Zubin Zhou; Xiaochun Peng; Tianyi Wu; Yuqiang Sun
Journal:  Int Orthop       Date:  2013-06-12       Impact factor: 3.075

9.  Technical Note on Placement of Low-Profile Triangular Osteosynthesis for Unstable Posterior Pelvic Ring Injuries.

Authors:  Kevin Steelman; Ryan Bray; Rahul Vaidya
Journal:  J Orthop Trauma       Date:  2021-10-19       Impact factor: 2.884

10.  Treatment of Unstable Posterior Pelvic Ring Fracture with Pedicle Screw-Rod Fixator Versus Locking Compression Plate: A Comparative Study.

Authors:  Chun Bi; Qiugen Wang; Christopher Nagelli; Jianhong Wu; Qian Wang; Jiandong Wang
Journal:  Med Sci Monit       Date:  2016-10-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.