Abstract

OBJECTIVE: The goal of this study was to evaluate the biomechanical features of human cadaveric spines implanted with the Activ L prosthesis.
METHODS: Five cadaveric human lumbosacral spines (L2-S2) were tested for different motion modes, i.e. extension and flexion, right and left lateral bending and rotation. Baseline measurements of the range of motion (ROM), disc pressure (DP), and facet strain (FS) were performed in six modes of motion by applying loads up to 8 Nm, with a loading rate of 0.3 Nm/second. A constant 400 N axial follower preload was applied throughout the loading. After the Activ L was implanted at the L4-L5 disc space, measurements were repeated in the same manner.
RESULTS: The Activ L arthroplasty showed statistically significant decrease of ROM during rotation, increase of ROM during flexion and lateral bending at the operative segment and increase of ROM at the inferior segment during flexion. The DP of the superior disc of the operative site was comparable to those of intact spine and the DP of the inferior disc decreased in all motion modes, but these were not statistically significant. For FS, statistically significant decrease was detected at the operative facet during flexion and at the inferior facet during rotation.
CONCLUSION: In vitro physiologic preload setting, the Activ L arthroplasty showed less restoration of ROM at the operative and adjacent levels as compared with intact spine. However, results of this study revealed that there are several possible theoretical useful results to reduce the incidence of adjacent segment disease.

Entities:  

Keywords:  Activ L; Biomechanics; Disc pressure; Facet strain; Lumbar spinal arthroplasty; Range of motion

Year:  2009        PMID: 19352479      PMCID: PMC2666119          DOI: 10.3340/jkns.2009.45.3.169

Source DB:  PubMed          Journal:  J Korean Neurosurg Soc        ISSN: 1225-8245


  21 in total

1.  Spine arthroplasty: a historical review.

Authors:  Marek Szpalski; Robert Gunzburg; Michael Mayer
Journal:  Eur Spine J       Date:  2002-08-13       Impact factor: 3.134

2.  Biomechanical studies of an artificial disc implant in the human cadaveric spine.

Authors:  Patrick W Hitchon; Kurt Eichholz; Christopher Barry; Paige Rubenbauer; Aditya Ingalhalikar; Satoshi Nakamura; Kenneth Follett; Tae Hong Lim; James Torner
Journal:  J Neurosurg Spine       Date:  2005-03

3.  Load-sharing between anterior and posterior elements in a lumbar motion segment implanted with an artificial disc.

Authors:  A P Dooris; V K Goel; N M Grosland; L G Gilbertson; D G Wilder
Journal:  Spine (Phila Pa 1976)       Date:  2001-03-15       Impact factor: 3.468

4.  Arthroplasty with intercorporal endoprothesis in herniated disc and in painful disc.

Authors:  U Fernström
Journal:  Acta Chir Scand Suppl       Date:  1966

5.  2001 Volvo Award Winner in Clinical Studies: Lumbar fusion versus nonsurgical treatment for chronic low back pain: a multicenter randomized controlled trial from the Swedish Lumbar Spine Study Group.

Authors:  P Fritzell; O Hägg; P Wessberg; A Nordwall
Journal:  Spine (Phila Pa 1976)       Date:  2001-12-01       Impact factor: 3.468

6.  Long-term follow-up of functional outcomes and radiographic changes at adjacent levels following lumbar spine fusion for degenerative disc disease.

Authors:  M N Kumar; F Jacquot; H Hall
Journal:  Eur Spine J       Date:  2001-08       Impact factor: 3.134

7.  Correlation between sagittal plane changes and adjacent segment degeneration following lumbar spine fusion.

Authors:  M N Kumar; A Baklanov; D Chopin
Journal:  Eur Spine J       Date:  2001-08       Impact factor: 3.134

8.  Degenerative disc disease treated with combined anterior and posterior arthrodesis and posterior instrumentation.

Authors:  Kathleen R Moore; Manuel R Pinto; Lisa M Butler
Journal:  Spine (Phila Pa 1976)       Date:  2002-08-01       Impact factor: 3.468

9.  Lumbar total disc replacement. Seven to eleven-year follow-up.

Authors:  Patrick Tropiano; Russel C Huang; Federico P Girardi; Frank P Cammisa; Thierry Marnay
Journal:  J Bone Joint Surg Am       Date:  2005-03       Impact factor: 5.284

10.  The prevalence of disc aging and back pain after fusion extending into the lower lumbar spine. A matched MR study twenty-five years after surgery for adolescent idiopathic scoliosis.

Authors:  A J Danielsson; C G Cederlund; S Ekholm; A L Nachemson
Journal:  Acta Radiol       Date:  2001-03       Impact factor: 1.701

View more
  10 in total

Review 1.  Limitations of current in vitro test protocols for investigation of instrumented adjacent segment biomechanics: critical analysis of the literature.

Authors:  David Volkheimer; Masoud Malakoutian; Thomas R Oxland; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2015-06-03       Impact factor: 3.134

2.  Clinical, radiological, histological and retrieval findings of Activ-L and Mobidisc total disc replacements: a study of two patients.

Authors:  Shennah Austen; Ilona M Punt; Jack P M Cleutjens; Paul C Willems; Steven M Kurtz; Daniel W MacDonald; Lodewijk W van Rhijn; André van Ooij
Journal:  Eur Spine J       Date:  2012-01-15       Impact factor: 3.134

Review 3.  Meta-analyses comparing spine simulators with cadavers and finite element models by analysing range-of-motion data before and after lumbar total disc replacement.

Authors:  Tobias Bohn; Susanne A J Lang; Stephanie Roll; Helene Schrader; Matthias Pumberger; Karin Büttner-Janz
Journal:  J Adv Res       Date:  2020-06-23       Impact factor: 10.479

4.  The Changes in Range of Motion after a Lumbar Spinal Arthroplasty with Charité in the Human Cadaveric Spine under Physiologic Compressive Follower Preload : A Comparative Study between Load Control Protocol and Hybrid Protocol.

Authors:  Se-Hoon Kim; Ung-Kyu Chang; Jae-Chil Chang; Kwon-Soo Chun; T Jesse Lim; Daniel H Kim
Journal:  J Korean Neurosurg Soc       Date:  2009-08-31

5.  We Need to Talk about Lumbar Total Disc Replacement.

Authors:  Stephen Beatty
Journal:  Int J Spine Surg       Date:  2018-08-03

6.  Biomechanics of disc degeneration.

Authors:  V Palepu; M Kodigudla; V K Goel
Journal:  Adv Orthop       Date:  2012-06-17

7.  The current testing protocols for biomechanical evaluation of lumbar spinal implants in laboratory setting: a review of the literature.

Authors:  Sabrina A Gonzalez-Blohm; James J Doulgeris; William E Lee; Thomas M Shea; Kamran Aghayev; Frank D Vrionis
Journal:  Biomed Res Int       Date:  2015-02-15       Impact factor: 3.411

8.  Biomechanical effects of semi-constrained integrated artificial discs on zygapophysial joints of implanted lumbar segments.

Authors:  Sheng-Nai Zheng; Qing-Qiang Yao; Li-Ming Wang; Wen-Hao Hu; Bo Wei; Yan Xu; Dong-Sheng Zhang
Journal:  Exp Ther Med       Date:  2013-09-26       Impact factor: 2.447

9.  ISASS Policy Statement - Lumbar Artificial Disc.

Authors:  Jack Zigler; Rolando Garcia
Journal:  Int J Spine Surg       Date:  2015-03-12

10.  Retrospective study on effectiveness of Activ L total disc replacement.

Authors:  Wenzhi Sun; Peng Wang; Hailiang Hu; Chao Kong; Yong Hai; Shibao Lu
Journal:  J Orthop Surg Res       Date:  2021-01-04       Impact factor: 2.359

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.