Large coherence length swept source for axial length measurement of the eye.

Changho Chong1, Takuya Suzuki, Kohki Totsuka, Atsushi Morosawa, Tooru Sakai.   

Abstract

We present and demonstrate a swept source with a large coherence length using a quasi-phase continuous tuning (QPCT) technique. QPCT is a method of minimizing the phase shift per round trip with respect to the tunable filter so that the resonance of lasing becomes high, resulting in high finesse of lasing during a rapid sweep. The demonstrated swept source consists of a fiber ring extended cavity laser with a diffraction grating and a polygon scanner-based tunable filter configuration. The projected beam on the diffraction grating is expanded with a multiple of beam expanders to achieve high finesse of the filter. The source demonstrated an 18 nm swept range at 1060 nm wavelength, 28 mm coherence length, and 6.2 mW peak power at a 2.5 kHz swept rate. OCT imaging results showed that a coherence length of 28 mm enables the measurement of the axial length of a pig's eye with 20 mm length in physical size.

Entities:  

Mesh:

Year:  2009        PMID: 19340103     DOI: 10.1364/ao.48.00d144

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  6 in total

Review 1.  The parameters of the porcine eyeball.

Authors:  Irene Sanchez; Raul Martin; Fernando Ussa; Ivan Fernandez-Bueno
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-02-02       Impact factor: 3.117

Review 2.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

3.  Reproducibility of a long-range swept-source optical coherence tomography ocular biometry system and comparison with clinical biometers.

Authors:  Ireneusz Grulkowski; Jonathan J Liu; Jason Y Zhang; Benjamin Potsaid; Vijaysekhar Jayaraman; Alex E Cable; Jay S Duker; James G Fujimoto
Journal:  Ophthalmology       Date:  2013-06-04       Impact factor: 12.079

4.  Investigation of the impact of water absorption on retinal OCT imaging in the 1060 nm range.

Authors:  Sebastian Marschall; Christian Pedersen; Peter E Andersen
Journal:  Biomed Opt Express       Date:  2012-06-18       Impact factor: 3.732

5.  Enhanced Penetration for Axial Length Measurement of Eyes with Dense Cataracts Using Swept Source Optical Coherence Tomography: A Consecutive Observational Study.

Authors:  Nino Hirnschall; Ralph Varsits; Birgit Doeller; Oliver Findl
Journal:  Ophthalmol Ther       Date:  2018-03-01

6.  Partially coherent radar unties range resolution from bandwidth limitations.

Authors:  Rony Komissarov; Vitali Kozlov; Dmitry Filonov; Pavel Ginzburg
Journal:  Nat Commun       Date:  2019-03-29       Impact factor: 14.919