Two-body wear of artificial acrylic and composite resin teeth in relation to antagonist material.

Sebastian Hahnel1, Michael Behr, Gerhard Handel, Martin Rosentritt.   

Abstract

STATEMENT OF PROBLEM: Wear resistance is one of the most important physical properties of artificial resin teeth, and its dependence on the antagonist material has not been clearly established.
PURPOSE: The purpose of this in vitro study was to investigate the wear resistance of representative artificial resin teeth in relation to antagonist material.
MATERIAL AND METHODS: Twenty-four standardized specimens were prepared for each of 8 tooth types representative of anterior and posterior artificial acrylic and composite resin teeth (Gnathostar, SR Orthosit PE, Condyloform II NFC, SR Postaris DCL, SR Vivodent PE, VITA Physiodens, SR Antaris DCL, Bioplus), for a total of 192 specimens. Each specimen was prepared to a diameter of 5 mm and a thickness of 2 mm on the buccal/facial tooth surfaces. The specimens were then polished and subjected to simulated mastication (50 N, 1.2 x 10(5) cycles, 1.2 Hz) using a pin-on-block design and additional thermocycling (600 cycles, 5/55 degrees C, 2 min/cycle). Three antagonists (artificial resin teeth, steel, steatite) were prepared, and 8 specimens per tooth type were tested for each antagonist. Vertical substance and volume loss were analyzed using cast replicas and an optical 3-dimensional (3-D) surface profilometer, as well as scanning electron microscopy. Data were analyzed using 2- and 1-way ANOVA and the Games-Howell test (alpha=.05).
RESULTS: For both vertical substance and volume loss, significant differences were found for the various antagonists. Lowest overall mean values (SD) for vertical substance and volume loss were measured for artificial tooth antagonists (26 (10) microm to 95 (46) microm, 1.5 (1.5) microm(3) to 10.5 (9) microm(3)), and the highest values were measured for steatite antagonists (95 (23) microm to 723 (168) microm, 8 (4) microm(3) to 245 (109) microm(3)). Intermediate mean values (SD) for vertical substance and volume loss were measured for steel antagonists (118 (88) microm to 205 (120) microm, 9 (7) microm(3) to 28 (24) microm(3)). Using artificial teeth and steel antagonists, few significant differences in wear resistance were found between the various resin teeth. In contrast, significant differences were observed with steatite antagonists.
CONCLUSIONS: The use of steatite antagonists allowed for significantly better differentiation of wear behavior between various artificial teeth than the use of artificial resin teeth or steel antagonists.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19328280     DOI: 10.1016/S0022-3913(09)60051-2

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  13 in total

1.  Two-body wear of dental porcelain and substructure oxide ceramics.

Authors:  Martin Rosentritt; Verena Preis; Michael Behr; Sebastian Hahnel; Gerhard Handel; Carola Kolbeck
Journal:  Clin Oral Investig       Date:  2011-07-08       Impact factor: 3.573

2.  [Study on friction and wear properties of dental zirconia ceramics processed by microwave and conventional sintering methods].

Authors:  Hu Guoxin; Yang Ying; Jiang Yuemei; Xia Wenjing
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2017-04-01

3.  Factors affecting wear of composite resin denture teeth--24-month results from a clinical study.

Authors:  Thomas Stober; Andreas Geiger; Stefan Rues; Jens Dreyhaupt; Peter Rammelsberg; Brigitte Ohlmann
Journal:  Clin Oral Investig       Date:  2011-03-08       Impact factor: 3.573

4.  Two Body Wear of Newly Introduced Nanocomposite Teeth and Cross Linked Four Layered Acrylic Teeth: a Comparitive In Vitro Study.

Authors:  R Ilangkumaran; J Srinivasan; K Baburajan; N Balaji
Journal:  J Indian Prosthodont Soc       Date:  2014-07-17

5.  Prosthetic management of an extensive maxillary alveolar defect with an implant-supported restoration.

Authors:  Fariborz Saadat; Ramin Mosharraf
Journal:  J Dent (Tehran)       Date:  2013-05

6.  Two-body wear of occlusal splint materials against different antagonists.

Authors:  Kubra Yildiz Domanic; Yilmaz Umut Aslan; Yasemin Ozkan
Journal:  BMC Oral Health       Date:  2020-06-22       Impact factor: 2.757

7.  Full Mouth Oral Rehabilitation by Maxillary Implant Supported Hybrid Denture Employing a Fiber Reinforced Material Instead of Conventional PMMA.

Authors:  Ala Hassan A Qamheya; Sinem Yeniyol; Volkan Arısan
Journal:  Case Rep Dent       Date:  2015-10-18

8.  Wear of two pit and fissure sealants in contact with primary teeth.

Authors:  Rodrigo Galo; Marta Maria Martins Giamatei Contente; Maria Cristina Borsatto
Journal:  Eur J Dent       Date:  2014-04

9.  Abrasion wear resistance of different artificial teeth opposed to metal and composite antagonists.

Authors:  Pâmela Carbone Mello; Abílio Ricciardi Coppedê; Ana Paula Macedo; Maria da Gloria Chiarello de Mattos; Renata Cristina Silveira Rodrigues; Ricardo Faria Ribeiro
Journal:  J Appl Oral Sci       Date:  2009 Sep-Oct       Impact factor: 2.698

10.  Wear of primary teeth caused by opposed all-ceramic or stainless steel crowns.

Authors:  Jae-Won Choi; Ik-Hyun Bae; Tae-Hwan Noh; Sung-Won Ju; Tae-Kyoung Lee; Jin-Soo Ahn; Tae-Sung Jeong; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.