Literature DB >> 19320855

Performance of three automated fourth-generation combined HIV antigen/antibody assays in large-scale screening of blood donors and clinical samples.

K Malm1, M von Sydow, S Andersson.   

Abstract

Since the introduction in the mid-1980s, HIV testing has gradually improved both in terms of sensitivity and specificity. The so-called fourth generation of tests, combined HIV antigen/antibody assays, has now been introduced. This study compares three automated combined assays with older third-generation antibody assays in large-scale screening. Serum samples from routine screening of blood and plasma donors and clinical samples were investigated for specificity evaluation. Three fourth-generation combination assays from one manufacturer were compared with three older third-generation antibody assays from the same manufacturer. More than 40 000 samples per assay were included. For sensitivity, selected panels of confirmed HIV-1- and HIV-2-positive samples as well as seroconversion samples (HIV-1) from commercial panels and also from patients who appeared during the evaluation were used. The specificities of the fourth-generation tests were 99.91% (AxSYM), 99.95% (ARCHITECT) and 99.97% (PRISM) after repeated testing. Some specificity variation between reagent batches was observed. All HIV-1-positive samples were reactive by the three fourth-generation systems. HIV-1 seroconversion samples and panels were reactive earlier than by antibody-only tests. As for HIV-2 samples, AxSYM failed to detect one (n = 40), whereas PRISM and ARCHITECT detected all (n = 16 for PRISM and n = 52 for ARCHITECT). The new HIV antigen/antibody combination assay systems were found to have high sensitivity and specificity. The instruments provided a rational and easy way of testing at large scale.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19320855     DOI: 10.1111/j.1365-3148.2009.00907.x

Source DB:  PubMed          Journal:  Transfus Med        ISSN: 0958-7578            Impact factor:   2.019


  10 in total

1.  A conceptual model of interventions to increase diagnosis of acute HIV infection and reduce forward transmission.

Authors:  Andrew E Petroll; Steven D Pinkerton
Journal:  AIDS Behav       Date:  2011-11

2.  Cost-effectiveness of nucleic acid amplification tests for identifying acute HIV infections.

Authors:  Jean Maritz; Wolfgang Preiser
Journal:  J Clin Microbiol       Date:  2011-04       Impact factor: 5.948

3.  Cost savings associated with testing of antibodies, antigens, and nucleic acids for diagnosis of acute HIV infection.

Authors:  Maile Y Karris; Christy M Anderson; Sheldon R Morris; Davey M Smith; Susan J Little
Journal:  J Clin Microbiol       Date:  2012-03-21       Impact factor: 5.948

4.  New automated chemiluminescence immunoassay for simultaneous but separate detection of human immunodeficiency virus antigens and antibodies.

Authors:  Roberto Alonso; Paula López Roa; Marisol Suárez; Emilio Bouza
Journal:  J Clin Microbiol       Date:  2014-02-26       Impact factor: 5.948

5.  Improving HIV-2 detection by a combination of serological and nucleic acid amplification test assays.

Authors:  Anna Rita Ciccaglione; Michela Miceli; Giulio Pisani; Roberto Bruni; Paola Iudicone; Angela Costantino; Michele Equestre; Elena Tritarelli; Cinzia Marcantonio; Paola Tataseo; Maria Cristina Marazzi; Susanna Ceffa; Giovanna Paturzo; Anna Maria Doro Altan; Massimo Magnano San Lio; Sandro Mancinelli; Massimo Ciccozzi; Alessandra Lo Presti; Giovanni Rezza; Leonardo Palombi
Journal:  J Clin Microbiol       Date:  2010-06-23       Impact factor: 5.948

6.  Clinical evaluation of BioPlex 2200 HIV Ag-Ab, an automated screening method providing discrete detection of HIV-1 p24 antigen, HIV-1 antibody, and HIV-2 antibody.

Authors:  Maud Salmona; Severine Delarue; Constance Delaugerre; François Simon; Sarah Maylin
Journal:  J Clin Microbiol       Date:  2013-10-23       Impact factor: 5.948

7.  Performance evaluation of a new fourth-generation HIV combination antigen-antibody assay.

Authors:  A Mühlbacher; H Schennach; J van Helden; T Hebell; G Pantaleo; P Bürgisser; C Cellerai; P Permpikul; M I Rodriguez; A Eiras; F Alborino; P Cunningham; M Axelsson; S Andersson; O Wetlitzky; C Kaiser; P Möller; G de Sousa
Journal:  Med Microbiol Immunol       Date:  2012-06-17       Impact factor: 3.402

8.  Analytical and Clinical Performance Evaluation of the Elecsys HIV combi PT Assay on the cobas e 602 Analyzer for the Diagnosis of Human Immunodeficiency Virus.

Authors:  Denise L Uettwiller-Geiger; Marvin Lessig; Jie An; Tara Barsch; Susan Smith; Sharan Walker; Alexander Riedel; Yi Hao; Amin A Mohammad
Journal:  Am J Clin Pathol       Date:  2019-03-01       Impact factor: 2.493

9.  Decreasing Proportion of Recent Infections among Newly Diagnosed HIV-1 Cases in Switzerland, 2008 to 2013 Based on Line-Immunoassay-Based Algorithms.

Authors:  Jörg Schüpbach; Christoph Niederhauser; Sabine Yerly; Stephan Regenass; Meri Gorgievski; Vincent Aubert; Diana Ciardo; Thomas Klimkait; Günter Dollenmaier; Corinne Andreutti; Gladys Martinetti; Marcel Brandenberger; Martin D Gebhardt
Journal:  PLoS One       Date:  2015-07-31       Impact factor: 3.240

Review 10.  A Review of Piezoelectric and Magnetostrictive Biosensor Materials for Detection of COVID-19 and Other Viruses.

Authors:  Fumio Narita; Zhenjin Wang; Hiroki Kurita; Zhen Li; Yu Shi; Yu Jia; Constantinos Soutis
Journal:  Adv Mater       Date:  2020-11-24       Impact factor: 32.086

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.