Literature DB >> 24574285

New automated chemiluminescence immunoassay for simultaneous but separate detection of human immunodeficiency virus antigens and antibodies.

Roberto Alonso1, Paula López Roa, Marisol Suárez, Emilio Bouza.   

Abstract

The recently launched Liaison XL Murex HIV Ab/Ag assay (DiaSorin S.p.A) uses chemiluminescence immunoassay technology for the combined qualitative determination of p24 antigen of HIV-1 and specific antibodies to both HIV-1 and HIV-2. We studied 571 serum samples from those submitted to our laboratory for HIV screening. The samples were divided into 3 subsets: subset A, 365 samples collected prospectively during 1 week; subset B, 158 samples from confirmed HIV-positive patients; and subset C, 48 samples with a positive screening result but a negative or indeterminate confirmatory test result. Our standard screening/confirmatory algorithm was used as a reference. In subset A (prospective), 5 samples were positive and 360 negative by the standard procedure. Liaison XL Murex HIV Ab/Ag correctly identified all 5 positive samples (100%) and 357 negative samples (99.2%). In subset B (confirmed positive), all 158 positive samples were in total agreement in both procedures. In subset C (screen positive only), Liaison XL Murex HIV Ab/Ag yielded accurate results in 42 out of 48 samples (87.5%). Global sensitivity and specificity for Liaison XL Murex HIV Ab/Ag (all subsets included) were 98.3% and 98.5%, respectively. Considering only nonselected prospective samples and confirmed positive samples (subsets A and B), the corresponding sensitivity and specificity values were 100% and 99.2%, respectively. The new fully automated HIV screening test showed high sensitivity and specificity compared to our standard algorithm. Its added advantage of being able to detect HIV-1 and HIV-2 antibodies and p24 antigen separately could prove useful in the diagnosis of early infections.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24574285      PMCID: PMC3993662          DOI: 10.1128/JCM.03486-13

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  22 in total

Review 1.  HIV controllers: a genetically determined or inducible phenotype?

Authors:  Asier Sáez-Cirión; Gianfranco Pancino
Journal:  Immunol Rev       Date:  2013-07       Impact factor: 12.988

2.  Early detection of human immunodeficiency virus infection using third- and fourth-generation screening assays.

Authors:  T D Ly; S Laperche; A M Couroucé
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2001-02       Impact factor: 3.267

3.  Clinical evaluation of BioPlex 2200 HIV Ag-Ab, an automated screening method providing discrete detection of HIV-1 p24 antigen, HIV-1 antibody, and HIV-2 antibody.

Authors:  Maud Salmona; Severine Delarue; Constance Delaugerre; François Simon; Sarah Maylin
Journal:  J Clin Microbiol       Date:  2013-10-23       Impact factor: 5.948

4.  Shortening of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1/2/O screening test.

Authors:  S Brust; H Duttmann; J Feldner; L Gürtler; R Thorstensson; F Simon
Journal:  J Virol Methods       Date:  2000-11       Impact factor: 2.014

5.  Evaluation of a new combined antigen and antibody human immunodeficiency virus screening assay, VIDAS HIV DUO Ultra.

Authors:  Bernard Weber; Annemarie Berger; Holger Rabenau; Hans Wilhelm Doerr
Journal:  J Clin Microbiol       Date:  2002-04       Impact factor: 5.948

6.  Clinical performance of the novel DiaSorin LIAISON(®) XL murex: HBsAg Quant, HCV-Ab, HIV-Ab/Ag assays.

Authors:  Adalbert Krawczyk; Christian Hintze; Jessica Ackermann; Birgit Goitowski; Martin Trippler; Nico Grüner; Maria Neumann-Fraune; Jens Verheyen; Melanie Fiedler
Journal:  J Clin Virol       Date:  2013-11-07       Impact factor: 3.168

7.  The variable sensitivity of HIV Ag/Ab combination assays in the detection of p24Ag according to genotype could compromise the diagnosis of early HIV infection.

Authors:  Thoai Duong Ly; Jean Christophe Plantier; Lionel Leballais; Sylvie Gonzalo; Véronique Lemée; Syria Laperche
Journal:  J Clin Virol       Date:  2012-07-13       Impact factor: 3.168

8.  Reduction of diagnostic window by new fourth-generation human immunodeficiency virus screening assays.

Authors:  B Weber; E H Fall; A Berger; H W Doerr
Journal:  J Clin Microbiol       Date:  1998-08       Impact factor: 5.948

9.  [HIV-2 and HTLV-I/II infections in Spain].

Authors:  Carlos Toro; Berta Rodés; Antonio Aguilera; Estrella Caballero; Rafael Benito; Sylvina Bassani; Carmen Rodríguez; Concepción Tuset; Raúl Ortiz de Lejarazu; José Eirós; Juan García; Enrique Calderón; Francisco J Capote; Alejandro Vallejo; Maite Gutiérrez; Vicente Soriano
Journal:  Enferm Infecc Microbiol Clin       Date:  2004-03       Impact factor: 1.731

10.  Performance evaluation of a new fourth-generation HIV combination antigen-antibody assay.

Authors:  A Mühlbacher; H Schennach; J van Helden; T Hebell; G Pantaleo; P Bürgisser; C Cellerai; P Permpikul; M I Rodriguez; A Eiras; F Alborino; P Cunningham; M Axelsson; S Andersson; O Wetlitzky; C Kaiser; P Möller; G de Sousa
Journal:  Med Microbiol Immunol       Date:  2012-06-17       Impact factor: 3.402

View more
  3 in total

1.  Rapid immunodiagnostics of multiple viral infections in an acoustic microstreaming device with serum and saliva samples.

Authors:  Neha Garg; Dylan Boyle; Arlo Randall; Andy Teng; Jozelyn Pablo; Xiaowu Liang; David Camerini; Abraham P Lee
Journal:  Lab Chip       Date:  2019-04-23       Impact factor: 6.799

2.  Chemiluminescence Immunoassay for the Detection of Antibodies against the 2C and 3ABC Nonstructural Proteins Induced by Infecting Pigs with Foot-and-Mouth Disease Virus.

Authors:  Zezhong Liu; Junjun Shao; Furong Zhao; Guangqing Zhou; Shandian Gao; Wei Liu; Jianliang Lv; Xiumei Li; Yangfan Li; Huiyun Chang; Yongguang Zhang
Journal:  Clin Vaccine Immunol       Date:  2017-08-04

3.  Performance of the Liaison XL Murex HIV Ab/Ag test on clinical samples representing current epidemic HIV variants.

Authors:  Véronique Lemee; Marie Leoz; Manuel Etienne; Fabienne De Oliveira; Jean-Christophe Plantier
Journal:  J Clin Microbiol       Date:  2014-06-25       Impact factor: 5.948

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.