Literature DB >> 19320730

Effect of framework design on crown failure.

Estevam A Bonfante1, Nelson R F A da Silva, Paulo G Coelho, Daniel E Bayardo-González, Van P Thompson, Gerson Bonfante.   

Abstract

This study evaluated the effect of core-design modification on the characteristic strength and failure modes of glass-infiltrated alumina (In-Ceram) (ICA) compared with porcelain fused to metal (PFM). Premolar crowns of a standard design (PFMs and ICAs) or with a modified framework design (PFMm and ICAm) were fabricated, cemented on dies, and loaded until failure. The crowns were loaded at 0.5 mm min(-1) using a 6.25 mm tungsten-carbide ball at the central fossa. Fracture load values were recorded and fracture analysis of representative samples were evaluated using scanning electron microscopy. Probability Weibull curves with two-sided 90% confidence limits were calculated for each group and a contour plot of the characteristic strength was obtained. Design modification showed an increase in the characteristic strength of the PFMm and ICAm groups, with PFM groups showing higher characteristic strength than ICA groups. The PFMm group showed the highest characteristic strength among all groups. Fracture modes of PFMs and of PFMm frequently reached the core interface at the lingual cusp, whereas ICA exhibited bulk fracture through the alumina core. Core-design modification significantly improved the characteristic strength for PFM and for ICA. The PFM groups demonstrated higher characteristic strength than both ICA groups combined.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19320730     DOI: 10.1111/j.1600-0722.2008.00608.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  13 in total

1.  Modified Y-TZP core design improves all-ceramic crown reliability.

Authors:  N R F A Silva; E A Bonfante; B T Rafferty; R A Zavanelli; E D Rekow; V P Thompson; P G Coelho
Journal:  J Dent Res       Date:  2010-11-05       Impact factor: 6.116

2.  On the interfacial fracture of porcelain/zirconia and graded zirconia dental structures.

Authors:  Herzl Chai; James J-W Lee; Adam J Mieleszko; Stephen J Chu; Yu Zhang
Journal:  Acta Biomater       Date:  2014-04-24       Impact factor: 8.947

3.  Comparison of implant versus tooth-supported zirconia-based single crowns in a split-mouth design: a 4-year clinical follow-up study.

Authors:  Mustafa Barış Güncü; Umut Cakan; Guliz Aktas; Güliz Nigar Güncü; Şenay Canay
Journal:  Clin Oral Investig       Date:  2016-02-29       Impact factor: 3.573

4.  Reliability of reduced-thickness and thinly veneered lithium disilicate crowns.

Authors:  N R F A Silva; E A Bonfante; L M Martins; G B Valverde; V P Thompson; J L Ferencz; P G Coelho
Journal:  J Dent Res       Date:  2011-12-28       Impact factor: 6.116

5.  Reliability of metalloceramic and zirconia-based ceramic crowns.

Authors:  N R F A Silva; E A Bonfante; R A Zavanelli; V P Thompson; J L Ferencz; P G Coelho
Journal:  J Dent Res       Date:  2010-07-26       Impact factor: 6.116

6.  Effect of framework type on survival probability of implant-supported temporary crowns: An in vitro study.

Authors:  Vinícius-Anéas Rodrigues; Amanda-Maria-de Oliveira Dal Piva; Claudio-Akira Yamaguchi; Alexandre-Luiz-Souto Borges; Marcio-Katsuyoshi Mukai; João-Paulo-Mendes Tribst
Journal:  J Clin Exp Dent       Date:  2020-05-01

7.  The effect of zirconia framework design on the failure of all-ceramic crown under static loading.

Authors:  Somchai Urapepon; Pakamard Taenguthai
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

8.  Influence of Different Framework Designs on the Fracture Properties of Ceria-Stabilized Tetragonal Zirconia/Alumina-Based All-Ceramic Crowns.

Authors:  Tomofumi Sawada; Sebastian Spintzyk; Christine Schille; Ernst Schweizer; Lutz Scheideler; Jürgen Geis-Gerstorfer
Journal:  Materials (Basel)       Date:  2016-05-05       Impact factor: 3.623

9.  Fracture Resistance of Zirconia Restorations with a Modified Framework Design.

Authors:  Sakineh Nikzadjamnani; Abbas Azari; Somayeh Niakan; Seyedeh Fatemeh Namdar
Journal:  J Dent (Tehran)       Date:  2017-11

10.  Effect of framework design on fracture resistance of zirconium oxide posterior fixed partial dentures.

Authors:  Hadi Salimi; Ramin Mosharraf; Omid Savabi
Journal:  Dent Res J (Isfahan)       Date:  2012-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.