Literature DB >> 19320573

Pseudo-outbreak of Legionella pneumophila serogroup 8 infection associated with a contaminated ice machine in a bronchoscopy suite.

A N Schuetz1, R L Hughes, R M Howard, T C Williams, F S Nolte, D Jackson, B S Ribner.   

Abstract

OBJECTIVE: To investigate the marked increase noted over an 8-month period in the number of Legionella pneumophila isolates recovered from bronchoalveolar lavage fluid specimens obtained during bronchoscopy in our healthcare system.
SETTING: Bronchoscopy suite that serves a 580-bed tertiary care center and a large, multisite, faculty practice plan with approximately 2 million outpatient visits per year.
METHODS: Cultures of environmental specimens from the bronchoscopy suite were performed, including samples from the air and water filters, bronchoscopes, and the ice machine, with the aim of identifying Legionella species. Specimens were filtered and acid-treated and then inoculated on buffered charcoal yeast extract agar. Serogrouping was performed on all isolates recovered from patient and environmental samples.
RESULTS: All L. pneumophila isolates recovered from patients were serogroup 8, a serogroup that is not usually recovered in our facility. An epidemiologic investigation of the bronchoscopy suite revealed the ice machine to be contaminated with L. pneumophila serogroup 8. Patients were exposed to the organism as a result of a recently adopted practice in the bronchoscopy suite that involved directly immersing uncapped syringes of sterile saline in contaminated ice baths during the procedures. At least 1 patient was ill as a result of the pseudo-outbreak. Molecular typing of isolates recovered from patient and environmental samples revealed that the isolates were indistinguishable.
CONCLUSIONS: Extensive cleaning of the ice machine and replacement of the machine's water filter ended the pseudo-outbreak. This episode emphasizes the importance of using aseptic technique when performing invasive procedures, such as bronchoscopies. It also demonstrates the importance of reviewing procedures in all patient areas to ensure compliance with facility policies for providing a safe patient environment.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19320573     DOI: 10.1086/596613

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  4 in total

Review 1.  Plumbing of hospital premises is a reservoir for opportunistically pathogenic microorganisms: a review.

Authors:  Margaret M Williams; Catherine R Armbruster; Matthew J Arduino
Journal:  Biofouling       Date:  2013       Impact factor: 3.797

2.  Legionella Risk Management and Control in Potable Water Systems: Argument for the Abolishment of Routine Testing.

Authors:  Harriet Whiley
Journal:  Int J Environ Res Public Health       Date:  2016-12-24       Impact factor: 3.390

Review 3.  Outbreaks of Legionnaires' Disease and Pontiac Fever 2006-2017.

Authors:  K A Hamilton; A J Prussin; W Ahmed; C N Haas
Journal:  Curr Environ Health Rep       Date:  2018-06

Review 4.  Uncertainties associated with assessing the public health risk from Legionella.

Authors:  Harriet Whiley; Alexandra Keegan; Howard Fallowfield; Kirstin Ross
Journal:  Front Microbiol       Date:  2014-09-24       Impact factor: 5.640