Literature DB >> 19318871

Optimal screw orientation for fixation of coronoid fractures.

Jun-Gyu Moon1, Mark E Zobitz, Kai-Nan An, Shawn W O'Driscoll.   

Abstract

OBJECTIVE: The aim of this study was to compare the fixation stability of coronoid fractures achieved by a screw inserted in the anteroposterior (AP) direction with that achieved by a screw inserted in the posteroanterior (PA) direction.
METHODS: Eleven pairs of fresh-frozen cadaveric ulna were used. A coronoid fracture was simulated by transverse osteotomy at the midpoint of coronoid height. The specimens of a pair were then randomized to be fixed with an AP screw in one specimen and a PA screw in the other. Insertion torque, load to failure, and stiffness were measured under axial load with a material testing machine.
RESULTS: PA screw placement yielded greater strength and stiffness of fixation than did AP placement. The mean load to failure was 184 N in the PA screw group and 131 N in the AP screw group (P < 0.05). The mean stiffness was 106 N/mm with PA screws and 76 N/mm with AP screws (P < 0.05). These differences were statistically significant despite the fact that the screw insertion torques was similar in PA screw (0.27 Nm) and AP screw (0.25 Nm) (P = 0.2).
CONCLUSIONS: PA screw placement was biomechanically superior to AP screw placement. Together with the fact that it is clinically easier to insert and remove screw from the posterior ulna, these data indicate that optimal screw orientation for fixation of coronoid tip fracture is posterior to anterior direction.

Entities:  

Mesh:

Year:  2009        PMID: 19318871     DOI: 10.1097/BOT.0b013e31819df8c9

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  8 in total

Review 1.  [Chronic bony instability of the elbow joint].

Authors:  J Geßmann; M Königshausen; T A Schildhauer; D Seybold
Journal:  Orthopade       Date:  2016-10       Impact factor: 1.087

2.  No neurovascular damage after creation of an accessory anteromedial portal for arthroscopic reduction and fixation of coronoid fractures.

Authors:  Paolo Arrigoni; Davide Cucchi; Enrico Guerra; Francesco Luceri; Simone Nicoletti; Alessandra Menon; Pietro Randelli
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-04-02       Impact factor: 4.342

Review 3.  Review of management of unstable elbow fractures.

Authors:  Omer Ozel; Emre Demircay
Journal:  World J Orthop       Date:  2016-01-18

4.  [Plate osteosynthesis of the coronoid process of the ulna].

Authors:  Valentin Rausch; Michael Hackl; Dominik Seybold; Kilian Wegmann; Lars P Müller
Journal:  Oper Orthop Traumatol       Date:  2020-01-15       Impact factor: 1.154

5.  Arthroscopic reduction and fixation of coronoid fractures with an exchange rod-a new technique.

Authors:  Kan Ouyang; Daping Wang; Wei Lu; Jianyi Xiong; Jian Xu; Liangquan Peng; Haifeng Liu; Hao Li; Wenzhe Feng
Journal:  J Orthop Surg Res       Date:  2017-01-18       Impact factor: 2.359

6.  Crista Supinatoris Fractures of the Proximal Part of the Ulna: Surgical Technique.

Authors:  William Desloges; George S Athwal; Ilia Elkinson; Graham J W King; Kenneth J Faber
Journal:  JBJS Essent Surg Tech       Date:  2015-02-25

7.  Biomechanical comparison of screw osteosyntheses and anatomical plating for coronoid shear fractures of the ulna.

Authors:  Valentin Rausch; Birger Jettkant; Sebastian Lotzien; Thomas Rosteius; Eileen Mempel; Thomas A Schildhauer; Dominik Seybold; Jan Geßmann; Matthias Königshausen
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-12       Impact factor: 3.067

Review 8.  Plate fixation through an anterior approach for coronoid process fractures: A retrospective case series and a literature review.

Authors:  Dongxu Feng; Xin Zhang; Yonghong Jiang; Yangjun Zhu; Hao Wang; Shufang Wu; Kun Zhang; Zhan Wang; Jun Zhang
Journal:  Medicine (Baltimore)       Date:  2018-09       Impact factor: 1.817

  8 in total