Literature DB >> 19299166

Rephasing ion packets in the Orbitrap mass analyzer to improve resolution and peak shape.

Richard H Perry1, Qizhi Hu, Gary A Salazar, R Graham Cooks, Robert J Noll.   

Abstract

A method is described to improve resolution and peak shape in the Orbitrap under certain experimental conditions. In these experiments, an asymmetric anharmonic axial potential was first produced in the Orbitrap by detuning the voltage on the compensator electrode, which results in broad and multiply split mass spectral peaks. An AC waveform applied to the outer electrode, 180 degrees out of phase with ion axial motion and resonant with the frequency of ion axial motion, caused ions of a given m/z to be de-excited to the equator (z = 0) and then immediately re-excited. This process, termed "rephasing," leaves the ion packet with a narrower axial spatial extent and frequency distribution. For example, when the Orbitrap axial potential is thus anharmonically de-tuned, a resolution of 124,000 to 171,000 is obtained, a 2- to 3-fold improvement over the resolution of 40,000 to 60,000 without rephasing, at 10 ng/microL reserpine concentration. Such a rephasing capability may ultimately prove useful in implementing tandem mass spectrometry (MS/MS) in the Orbitrap, bringing the Orbitrap's high mass accuracy and resolution to bear on both the precursor and product ions in the same MS/MS scan and making available the collision energy regime of the Orbitrap, approximately 1500 eV.

Mesh:

Year:  2009        PMID: 19299166     DOI: 10.1016/j.jasms.2009.02.011

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  29 in total

1.  Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis

Authors: 
Journal:  Anal Chem       Date:  2000-03-15       Impact factor: 6.986

Review 2.  Mass spectrometry in proteomics.

Authors:  R Aebersold; D R Goodlett
Journal:  Chem Rev       Date:  2001-02       Impact factor: 60.622

3.  Top-down mass spectrometry of a 29-kDa protein for characterization of any posttranslational modification to within one residue.

Authors:  Siu Kwan Sze; Ying Ge; HanBin Oh; Fred W McLafferty
Journal:  Proc Natl Acad Sci U S A       Date:  2002-02-12       Impact factor: 11.205

4.  Interfacing the orbitrap mass analyzer to an electrospray ion source.

Authors:  Mark Hardman; Alexander A Makarov
Journal:  Anal Chem       Date:  2003-04-01       Impact factor: 6.986

5.  The Orbitrap: a new mass spectrometer.

Authors:  Qizhi Hu; Robert J Noll; Hongyan Li; Alexander Makarov; Mark Hardman; R Graham Cooks
Journal:  J Mass Spectrom       Date:  2005-04       Impact factor: 1.982

6.  Application of a linear ion trap/orbitrap mass spectrometer in metabolite characterization studies: examination of the human liver microsomal metabolism of the non-tricyclic anti-depressant nefazodone using data-dependent accurate mass measurements.

Authors:  Scott M Peterman; Nicholas Duczak; Amit S Kalgutkar; Mary E Lame; John R Soglia
Journal:  J Am Soc Mass Spectrom       Date:  2006-01-25       Impact factor: 3.109

7.  Dynamic range of mass accuracy in LTQ Orbitrap hybrid mass spectrometer.

Authors:  Alexander Makarov; Eduard Denisov; Oliver Lange; Stevan Horning
Journal:  J Am Soc Mass Spectrom       Date:  2006-06-05       Impact factor: 3.109

8.  Femtomole sequencing of proteins from polyacrylamide gels by nano-electrospray mass spectrometry.

Authors:  M Wilm; A Shevchenko; T Houthaeve; S Breit; L Schweigerer; T Fotsis; M Mann
Journal:  Nature       Date:  1996-02-01       Impact factor: 49.962

9.  Determination of Synacthen in human plasma using immunoaffinity purification and liquid chromatography/tandem mass spectrometry.

Authors:  Mario Thevis; Michael Bredehöft; Hans Geyer; Matthias Kamber; Philippe Delahaut; Wilhelm Schänzer
Journal:  Rapid Commun Mass Spectrom       Date:  2006       Impact factor: 2.419

10.  Collision-induced dissociation pathways of yeast sphingolipids and their molecular profiling in total lipid extracts: a study by quadrupole TOF and linear ion trap-orbitrap mass spectrometry.

Authors:  Christer S Ejsing; Thomas Moehring; Ute Bahr; Eva Duchoslav; Michael Karas; Kai Simons; Andrej Shevchenko
Journal:  J Mass Spectrom       Date:  2006-03       Impact factor: 1.982

View more
  2 in total

1.  Optimal excitation and emission wavelengths to analyze amino acids and optimize neurotransmitters quantification using precolumn OPA-derivatization by HPLC.

Authors:  J Perucho; R Gonzalo-Gobernado; E Bazan; M J Casarejos; A Jiménez-Escrig; M J Asensio; A S Herranz
Journal:  Amino Acids       Date:  2015-02-18       Impact factor: 3.520

2.  Validation and application of sub-2 μm core-shell UHPLC-UV-ESI-Orbitrap MS for identification and quantification of β-carotene and selected cleavage products with preceding solid-phase extraction.

Authors:  G Martano; E Bojaxhi; I C Forstenlehner; C G Huber; N Bresgen; P M Eckl; H Stutz
Journal:  Anal Bioanal Chem       Date:  2014-03-21       Impact factor: 4.142

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.