Literature DB >> 19298293

Effects of decontamination and implant surface characteristics on re-osseointegration following treatment of peri-implantitis.

Ateş Parlar1, Dieter D Bosshardt, Deniz Cetiner, Denis Schafroth, Berrin Unsal, Cenk Haytaç, Niklaus P Lang.   

Abstract

BACKGROUND: Although considerable bone fill may occur following treatment of peri-implantitis, re-osseointegration appears to be limited and unpredictable.
OBJECTIVES: To evaluate the effects of various decontamination techniques and implant surface configurations on re-osseointegration of contaminated dental implants.
MATERIAL AND METHODS: Three months after tooth extraction, implants consisting of a basal part and an exchangeable intraosseous implant cylinder (EIIC) were placed in the mandibles of dogs. The EIIC was machined (M), sandblasted and acid-etched (SLA), or titanium plasma sprayed (TPS). Ligature-induced peri-implantitis was initiated 8 weeks post-implantation and lasted until bone loss reached the junction of the two implant parts. Three treatment modalities were applied: (T1) the EIIC was exchanged for a pristine EIIC; (T2) the EIIC was sprayed in situ with saline; and (T3) the EIIC was removed, cleansed outside the mouth by spraying with saline, steam-sterilized, and remounted. A collagen barrier was placed over each fixture, and 3 months later, samples were processed for histology and histomorphometry.
RESULTS: T2 revealed the highest bone-to-implant contact (BIC) level (significantly better than T1 and T3). T2 also yielded the highest bone crest level (significantly better than T1), followed by T3 (significantly better than T1). SLA showed the highest BIC level (significantly better than M), followed by TPS. There were no statistically significant differences in bone crest height between implant types.
CONCLUSIONS: Both SLA implants and in situ cleansing resulted in the best re-osseointegration and bone fill of previously contaminated implants.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19298293     DOI: 10.1111/j.1600-0501.2008.01655.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  12 in total

1.  Efficacy of Antimicrobial Photodynamic Therapy as an Adjunctive to Mechanical Debridement in the Treatment of Peri-implant Diseases: A Randomized Controlled Clinical Trial.

Authors:  Mohammad Reza Karimi; Ali Hasani; Salva Khosroshahian
Journal:  J Lasers Med Sci       Date:  2016-07-18

2.  Re-stability of dental implants following treatment of peri-implantitis.

Authors:  Fawad Javed; Hamza Ather Hussain; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-09-16

3.  In situ dental implant installation after decontamination in a previously peri-implant diseased site: a pilot study.

Authors:  Young-Taek Kim; Jae-Kook Cha; Jung-Chul Park; Ui-Won Jung; Chang-Sung Kim; Kyoo-Sung Cho; Seong-Ho Choi
Journal:  J Periodontal Implant Sci       Date:  2012-02-29       Impact factor: 2.614

4.  Nasopalatine duct cyst developed in association with dental implant treatment: A case report and histopathological observation.

Authors:  Kenji Takeshita; Katsuyuki Funaki; Ryo Jimbo; Tetsu Takahashi
Journal:  J Oral Maxillofac Pathol       Date:  2013-05

5.  Evaluation of Metalloproteinase-8 Levels in Crevicular Fluid of Patients with Healthy Implants or Periodontitis.

Authors:  Paweł Aleksandrowicz; Paulina Żelechowska; Justyna Agier; Katarzyna Starska; Krzysztof Kędzierski; Joanna Wysokińska-Miszczuk; Ewa Brzezińska-Błaszczyk
Journal:  Mediators Inflamm       Date:  2017-07-05       Impact factor: 4.711

6.  The effects of ozone therapy as an adjunct to the surgical treatment of peri-implantitis.

Authors:  Sila Cagri Isler; Berrin Unsal; Fatma Soysal; Gonen Ozcan; Elif Peker; Inci Rana Karaca
Journal:  J Periodontal Implant Sci       Date:  2018-06-30       Impact factor: 2.614

7.  Clinical and microbiologic investigation of an expedited peri-implantitis dog model: an animal study.

Authors:  Wook Jin Seong; Georgios Kotsakis; Jong-Ki Huh; Soo Cheol Jeong; Ki Young Nam; Jong Ryul Kim; Young Cheul Heo; Hyeon-Cheol Kim; Lei Zhang; Michael D Evans; Heather Conrad; Robert J Schumacher
Journal:  BMC Oral Health       Date:  2019-07-15       Impact factor: 2.757

8.  Decontamination of dental implant surfaces by means of photodynamic therapy.

Authors:  Juliana Marotti; Pedro Tortamano; Silvana Cai; Martha Simões Ribeiro; João Eduardo Miranda Franco; Tomie Toyota de Campos
Journal:  Lasers Med Sci       Date:  2012-07-12       Impact factor: 3.161

9.  Detoxification of implant surfaces affected by peri-implant disease: an overview of surgical methods.

Authors:  Pilar Valderrama; Thomas G Wilson
Journal:  Int J Dent       Date:  2013-08-04

10.  Evaluation of periimplant bone neoformation using different scanning electron microscope methods for measuring BIC. A dog study.

Authors:  José L Calvo-Guirado; Antonio Aguilar-Salvatierra; Javier Guardia; Rafael Delgado-Ruiz; María P Ramírez-Fernández; Cristina Pérez Sánchez; Gerardo Gómez-Moreno
Journal:  J Clin Exp Dent       Date:  2012-02-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.