The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: implications for tumour coverage.

Lasse Rye Aarup1, Alan E Nahum, Christina Zacharatou, Trine Juhler-Nøttrup, Tommy Knöös, Håkan Nyström, Lena Specht, Elinore Wieslander, Stine S Korreman.   

Abstract

PURPOSE: To evaluate against Monte-Carlo the performance of various dose calculations algorithms regarding lung tumour coverage in stereotactic body radiotherapy (SBRT) conditions.
MATERIALS AND METHODS: Dose distributions in virtual lung phantoms have been calculated using four commercial Treatment Planning System (TPS) algorithms and one Monte Carlo (MC) system (EGSnrc). We compared the performance of the algorithms in calculating the target dose for different degrees of lung inflation. The phantoms had a cubic 'body' and 'lung' and a central 2-cm diameter spherical 'tumour' (the body and tumour have unit density). The lung tissue was assigned five densities (rho(lung)): 0.01, 0.1, 0.2, 0.4 and 1g/cm(3). Four-field treatment plans were calculated with 6- and 18 MV narrow beams for each value of rho(lung). We considered the Pencil Beam Convolution (PBC(Ecl)) and the Analytical Anisotropic Algorithm (AAA(Ecl)) from Varian Eclipse and the Pencil Beam Convolution (PBC(OMP)) and the Collapsed Cone Convolution (CCC(OMP)) algorithms from Oncentra MasterPlan.
RESULTS: When changing rho(lung) from 0.4 to 0.1g/cm(3), the MC median target dose decreased from 89.2% to 74.9% for 6 MV and from 83.3% to 61.6% for 18 MV (of dose maximum in the homogenous case at both energies), while for both PB algorithms the median target dose was virtually independent of lung density.
CONCLUSIONS: Both PB algorithms overestimated the target dose, the overestimation increasing as rho(lung) decreased. Concerning target dose, the AAA(Ecl) and CCC(OMP) algorithms appear to be adequate alternatives to MC.

Entities:  

Mesh:

Year:  2009        PMID: 19297051     DOI: 10.1016/j.radonc.2009.01.008

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  44 in total

Review 1.  Intensity-Modulated Radiotherapy versus 3-Dimensional Conformal Radiotherapy Strategies for Locally Advanced Non-Small-Cell Lung Cancer.

Authors:  Uğur Selek; Yasemin Bölükbaşı; James W Welsh; Erkan Topkan
Journal:  Balkan Med J       Date:  2014-09-13       Impact factor: 2.021

2.  Correlation between pneumonitis risk in radiation oncology and lung density measured with X-ray computed tomography.

Authors:  Abdulhamid Chaikh; Jacques Balosso
Journal:  Quant Imaging Med Surg       Date:  2016-08

3.  Influence of respiration on dose calculation in stereotactic body radiotherapy of the lung.

Authors:  Rie Yamazaki; Rikiya Onimaru; Norio Katoh; Tetsuya Inoue; Takeshi Nishioka; Hiroki Shirato; Hiroyuki Date
Journal:  Radiol Phys Technol       Date:  2014-03-19

4.  Quantitative comparison of dose distribution in radiotherapy plans using 2D gamma maps and X-ray computed tomography.

Authors:  Abdulhamid Chaikh; Jacques Balosso
Journal:  Quant Imaging Med Surg       Date:  2016-06

5.  Integral dose: Comparison between four techniques for prostate radiotherapy.

Authors:  Krzysztof Ślosarek; Wojciech Osewski; Aleksandra Grządziel; Michał Radwan; Łukasz Dolla; Marta Szlag; Małgorzata Stąpór-Fudzińska
Journal:  Rep Pract Oncol Radiother       Date:  2014-11-18

6.  Algorithms used in heterogeneous dose calculations show systematic differences as measured with the Radiological Physics Center's anthropomorphic thorax phantom used for RTOG credentialing.

Authors:  Stephen F Kry; Paola Alvarez; Andrea Molineu; Carrie Amador; James Galvin; David S Followill
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-01-01       Impact factor: 7.038

Review 7.  Lung cancer. Radiotherapy in lung cancer: Actual methods and future trends.

Authors:  Adam Maciejczyk; Iga Skrzypczyńska; Marzena Janiszewska
Journal:  Rep Pract Oncol Radiother       Date:  2014-07-17

8.  CT-myelography for high-dose irradiation of spinal and paraspinal tumors with helical tomotherapy: revival of an old tool.

Authors:  Matthias Uhl; Florian Sterzing; Gregor Habl; Kai Schubert; Gabriele Sroka-Perez; Jürgen Debus; Klaus Herfarth
Journal:  Strahlenther Onkol       Date:  2011-06-27       Impact factor: 3.621

9.  On the dosimetric impact of inhomogeneity management in the Acuros XB algorithm for breast treatment.

Authors:  Antonella Fogliata; Giorgia Nicolini; Alessandro Clivio; Eugenio Vanetti; Luca Cozzi
Journal:  Radiat Oncol       Date:  2011-08-26       Impact factor: 3.481

10.  Dose measurements in a thorax phantom at 3DCRT breast radiation therapy.

Authors:  Elsa Bifano Pimenta; Luciana Batista Nogueira; Tarcísio Passos Ribeiro de Campos
Journal:  Rep Pract Oncol Radiother       Date:  2021-04-14
View more