Literature DB >> 19290511

Miniaturized 96-well ELISA chips for staphylococcal enterotoxin B detection using portable colorimetric detector.

Kim E Sapsford1, Jesse Francis, Steven Sun, Yordan Kostov, Avraham Rasooly.   

Abstract

A previously developed fluorescence sensing platform, combining spatial illumination using electroluminescence (EL) semiconductor strips with charge coupled device (CCD)-based detection (EL-CCD), was adapted to a new 96-well chip for colorimetric immunological assays, enhancing the capabilities of the EL-CCD platform. The modified system was demonstrated using a colorimetric-based enzyme linked immunosorbent assay (ELISA) for detection of staphylococcal enterotoxin B (SEB). Limits of detection (LODs) of 3.9 ng/mL (+/-2.4 ng/mL) SEB were determined with the ELISA chip measured using the EL-CCD platform, following a standard 4-h ELISA protocol. The LODs were comparable to those obtained using standard 96-well ELISA plates measured using a standard laboratory 96-well plate reader. The miniature 96-well ELISA chip however required as little as 5-microL samples, representing a tenfold reduction in sample volume compared to a standard 96-well ELISA plates. The ELISA chip also demonstrated detection of SEB spiked into various food matrices (milk, mushrooms, and mayonnaise) using limited-to-no sample preparation, with LODs ranging from 3.9 to 18.5 ng/mL depending on the matrix. The EL-CCD platform is versatile, capable of multi-mode detection (e.g., fluorescent and colorimetric along with solution and solid phase assays), and could readily be applied to other field portable or point-of-care applications.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19290511     DOI: 10.1007/s00216-009-2730-z

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  16 in total

1.  Image stacking approach to increase sensitivity of fluorescence detection using a low cost complementary metal-oxide-semiconductor (CMOS) webcam.

Authors:  Joshua Balsam; Hugh Alan Bruck; Yordan Kostov; Avraham Rasooly
Journal:  Sens Actuators B Chem       Date:  2012       Impact factor: 7.460

2.  Highly Expressed Recombinant SEB for Antibody Production and Development of Immunodetection System.

Authors:  Ranu Agrawal; Pawan Kumar Singh; Sushil Kumar Sharma; D V Kamboj; Ajay Kumar Goel; Lokendra Singh
Journal:  Indian J Microbiol       Date:  2011-03-30       Impact factor: 2.461

3.  A fluorometric assay for staphylococcal enterotoxin B by making use of platinum coated gold nanorods and of upconversion nanoparticles.

Authors:  Zhengzong Wu; Deyun He; Bo Cui
Journal:  Mikrochim Acta       Date:  2018-10-25       Impact factor: 5.833

4.  Electrical percolation-based biosensor for real-time direct detection of staphylococcal enterotoxin B (SEB).

Authors:  Minghui Yang; Steven Sun; Hugh Alan Bruck; Yordan Kostov; Avraham Rasooly
Journal:  Biosens Bioelectron       Date:  2010-04-21       Impact factor: 10.618

5.  An automated point-of-care system for immunodetection of staphylococcal enterotoxin B.

Authors:  Minghui Yang; Steven Sun; Yordan Kostov; Avraham Rasooly
Journal:  Anal Biochem       Date:  2011-05-17       Impact factor: 3.365

6.  Multi-wavelength Spatial LED illumination based detector for in vitro detection of Botulinum Neurotoxin A Activity.

Authors:  Steven Sun; Jesse Francis; Kim E Sapsford; Yordan Kostov; Avraham Rasooly
Journal:  Sens Actuators B Chem       Date:  2010-04-08       Impact factor: 7.460

7.  Rapid and Sensitive Colorimetric ELISA using Silver Nanoparticles, Microwaves and Split Ring Resonator Structures.

Authors:  Sarah A Addae; Melissa A Pinard; Humeyra Caglayan; Semih Cakmakyapan; Deniz Caliskan; Ekmel Ozbay; Kadir Aslan
Journal:  Nano Biomed Eng       Date:  2010-01-01

8.  Lab-on-a-chip for botulinum neurotoxin a (BoNT-A) activity analysis.

Authors:  Steven Sun; Miguel Ossandon; Yordan Kostov; Avraham Rasooly
Journal:  Lab Chip       Date:  2009-09-17       Impact factor: 6.799

9.  Thousand-fold fluorescent signal amplification for mHealth diagnostics.

Authors:  Joshua Balsam; Reuven Rasooly; Hugh Alan Bruck; Avraham Rasooly
Journal:  Biosens Bioelectron       Date:  2013-07-17       Impact factor: 10.618

10.  Capillary Array Waveguide Amplified Fluorescence Detector for mHealth.

Authors:  Joshua Balsam; Hugh Alan Bruck; Avraham Rasooly
Journal:  Sens Actuators B Chem       Date:  2013-09       Impact factor: 7.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.