Literature DB >> 19289850

Phase TEM for biological imaging utilizing a Boersch electrostatic phase plate: theory and practice.

Jessie Shiue1, Chia-Seng Chang, Sen-Hui Huang, Chih-Hao Hsu, Jin-Sheng Tsai, Wei-Hau Chang, Yi-Min Wu, Yen-Chen Lin, Pai-Chia Kuo, Yang-Shan Huang, Yeukuang Hwu, Ji-Jung Kai, Fan-Gang Tseng, Fu-Rong Chen.   

Abstract

A Boersch electrostatic phase plate (BEPP) used in a transmission electron microscope (TEM) system can provide tuneable phase shifts and overcome the low contrast problem for biological imaging. Theoretically, a pure phase image with a high phase contrast can be obtained using a BEPP. However, a currently available TEM system utilizing a BEPP cannot achieve sufficiently high phase efficiency for biological imaging, owing to the practical conditions. The low phase efficiency is a result of the blocking of partial unscattered electrons by BEPP, and the contribution of absorption contrast. The fraction of blocked unscattered beam is related to BEPP dimensions and to divergence of the illumination system of the TEM. These practical issues are discussed in this paper. Phase images of biological samples (negatively stained ferritin) obtained by utilizing a BEPP are reported, and the phase contrast was found to be enhanced by a factor of approximately 1.5, based on the calculation using the Rose contrast criterion. The low gain in phase contrast is consistent with the expectation from the current TEM/BEPP system. A new generation of phase TEM utilizing BEPP and designed for biological imaging with a high phase efficiency is proposed.

Mesh:

Substances:

Year:  2009        PMID: 19289850     DOI: 10.1093/jmicro/dfp006

Source DB:  PubMed          Journal:  J Electron Microsc (Tokyo)        ISSN: 0022-0744


  4 in total

1.  Retrofit implementation of Zernike phase plate imaging for cryo-TEM.

Authors:  Michael Marko; Ardean Leith; Chyongere Hsieh; Radostin Danev
Journal:  J Struct Biol       Date:  2011-01-25       Impact factor: 2.867

Review 2.  Invited review article: Methods for imaging weak-phase objects in electron microscopy.

Authors:  Robert M Glaeser
Journal:  Rev Sci Instrum       Date:  2013-11       Impact factor: 1.523

3.  Effect of fringe-artifact correction on sub-tomogram averaging from Zernike phase-plate cryo-TEM.

Authors:  Gregory P Kishchenko; Radostin Danev; Rebecca Fisher; Jie He; Chyongere Hsieh; Michael Marko; Haixin Sui
Journal:  J Struct Biol       Date:  2015-07-22       Impact factor: 2.867

4.  Hollow Cone Electron Imaging for Single Particle 3D Reconstruction of Proteins.

Authors:  Chun-Ying Tsai; Yuan-Chih Chang; Ivan Lobato; Dirk Van Dyck; Fu-Rong Chen
Journal:  Sci Rep       Date:  2016-06-13       Impact factor: 4.379