Literature DB >> 19289400

Effective dose conversion factors in paediatric interventional cardiology.

A Karambatsakidou1, B Sahlgren, B Hansson, M Lidegran, A Fransson.   

Abstract

Conversion factors for effective dose (CF(E) = effective dose/dose-area product (mSv (Gy cm2)(-1)) in paediatric interventional cardiology were estimated retrospectively for 249 patients using the dose-area product (DAP), irradiation geometry, exposure parameters and tissue-weighting factors (TWFs) from the International Commission on Radiological Protection (ICRP) 60. Two methods for estimating the conversion factors, which differed in the description of the irradiation geometry, were evaluated. The effective doses obtained with the two methods were almost identical. The results showed that irradiation geometry had no significant impact on the CF(E), and a single factor was defined for both diagnostic and interventional examinations. In addition, the effect of the new tissue-weighting factor for breast tissue (TWF(b)) given in ICRP 103 on the effective dose was assessed. The CF(E) was 3.7+/-0.2 mSv (Gy cm2)(-1) (neonate), 1.9+/-0.2 mSv (Gy cm2)(-1) (1 year), 1.0+/-0.1 mSv (Gy cm2)(-1) (5 years), 0.6+/-0.1 mSv (Gy cm2)(-1) (10 years) and 0.4+/-0.1 mSv (Gy cm2)(-1) (15 years). Applying these CFs to the individual DAP values of each patient yielded mean effective doses of 13.0 mSv (neonate), 8.6 mSv (1 year), 6.4 mSv (5 years), 8.6 mSv (10 years) and 12.7 mSv (15 years). The maximum estimated skin dose (15 patients) did not exceed 60 mGy. With the new ICRP value for TWF(b), increases in the CFs in the order of 10-30%, and in the effective dose of 10-20%, were indicated. The results indicated that the effective dose in paediatric interventional cardiology is of much greater concern than the skin dose. Furthermore, age-dependent CF(E) values are required so as not to underestimate the doses to very young patients.

Entities:  

Mesh:

Year:  2009        PMID: 19289400     DOI: 10.1259/bjr/57217783

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  6 in total

1.  Detection of pulmonary arterial morphology in tetralogy of Fallot with pulmonary atresia by computed tomography: 12 years of experience.

Authors:  Ming-Tai Lin; Jou-Kou Wang; Yih-Sharng Chen; Wen-Jeng Lee; Hsin-Hui Chiu; Chun-An Chen; Shuenn-Nan Chiu; En-Ting Wu; Chun-Wei Lu; Shu-Chien Huang; Shyh-Jye Chen; Ing-Sh Chiu; Chung-I Chang; Mei-Hwan Wu
Journal:  Eur J Pediatr       Date:  2011-11-15       Impact factor: 3.183

2.  Patient radiation doses and reference levels in pediatric interventional radiology.

Authors:  Bouchra Habib Geryes; Adeline Bak; Julie Lachaux; Augustin Ozanne; Nathalie Boddaert; Francis Brunelle; Olivier Naggara; Guillaume Saliou
Journal:  Eur Radiol       Date:  2017-02-16       Impact factor: 5.315

3.  No thyroid abnormalities in patients submitted to cardiac catheterization in the first eighteen months of life.

Authors:  M Cappa; P Cambiaso; E Genovese; D Kiepe; M Colajacomo; S Giannico; G Giannone; R Guglielmi; L Papini; V Cannatà
Journal:  J Endocrinol Invest       Date:  2011-12-21       Impact factor: 4.256

4.  Image quality of CT angiography with model-based iterative reconstruction in young children with congenital heart disease: comparison with filtered back projection and adaptive statistical iterative reconstruction.

Authors:  Sung Sil Son; Ki Seok Choo; Ung Bae Jeon; Gye Rok Jeon; Kyung Jin Nam; Tae Un Kim; Jeong A Yeom; Jae Yeon Hwang; Dong Wook Jeong; Soo Jin Lim
Journal:  Int J Cardiovasc Imaging       Date:  2014-11-21       Impact factor: 2.357

5.  Local reference levels and organ doses from pediatric cardiac interventional procedures.

Authors:  S Barnaoui; J L Rehel; H Baysson; Y Boudjemline; B Girodon; M O Bernier; D Bonnet; B Aubert
Journal:  Pediatr Cardiol       Date:  2014-03-21       Impact factor: 1.655

6.  Trends in the utilization of computed tomography and cardiac catheterization among children with congenital heart disease.

Authors:  Justin Cheng-Ta Yang; Ming-Tai Lin; Fu-Shan Jaw; Shyh-Jye Chen; Jou-Kou Wang; Tiffany Ting-Fang Shih; Mei-Hwan Wu; Yiu-Wah Li
Journal:  J Formos Med Assoc       Date:  2014-09-18       Impact factor: 3.282

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.