OBJECTIVES: To compare image quality of intraoral radiographs made with the Nomad portable X-ray unit (Aribex, Inc.) and with a wall-mounted dental X-ray machine in a clinical setting. METHODS AND MATERIALS: Twelve patients requiring a full-mouth radiographic series for diagnostic purposes were recruited for the study, in which half of the radiographs (one side selected randomly) were made with the Nomad and half with a wall-mounted dental X-ray machine. Each individual image was evaluated independently by three reviewers for diagnostic utility and quality, using a three-point scale: 2 = perfect radiograph; 1 = acceptable for diagnostic purposes despite a small error; 0 = unacceptable. A total score was derived for each of the 220 images, each of the 12 patients, and the study population as a whole.
RESULTS: The combined quality scores of the three reviewers for each set of radiographs ranged from 22-60 for the Nomad and 21-55 for the control units. Median scores were 33 for the Nomad and 33.5 for the control. The maximum possible score was nine films/half mouth x two points for perfect film x three reviewers = 54 (maximum 66 for 11 films). Three of the films, all on the same patient in a wheelchair, showed motion artifact (two with Nomad, one with control). DISCUSSION: Image quality for radiographs taken with the Nomad and a wall-mounted X-ray machine appears to be similar in a variety of clinical situations. Motion artifact is not a significant issue with the Nomad.

Entities:  

Mesh:

Year:  2009        PMID: 19288662

Source DB:  PubMed          Journal:  J Mich Dent Assoc        ISSN: 0026-2102


  3 in total

1.  The effects of device position on the operator's radiation dose when using a handheld portable X-ray device.

Authors:  Jimmy Makdissi; Ravikiran R Pawar; Ben Johnson; Bun S Chong
Journal:  Dentomaxillofac Radiol       Date:  2016-01-14       Impact factor: 2.419

2.  Precision of aiming with a portable X-ray device (Nomad Pro 2) compared to a wall-mounted device in intraoral radiography.

Authors:  Reinier C Hoogeveen; Bram R Meertens; W Erwin R Berkhout
Journal:  Dentomaxillofac Radiol       Date:  2019-05-13       Impact factor: 2.419

3.  Diagnostic image quality of hand-held and wall-mounted X-ray devices in bitewing radiography: a non-inferiority clinical trial.

Authors:  Reinier Cornelis Hoogeveen; Siham Ouchene; Wer Berkhout
Journal:  Dentomaxillofac Radiol       Date:  2021-01-08       Impact factor: 3.525

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.