Literature DB >> 19281291

Intermediate to long-term outcomes of endoluminal stent-graft repair in patients with chronic type B aortic dissection.

Ung Kim1, Sung-Jin Hong, Jaedeok Kim, Jung-Sun Kim, Young-Guk Ko, Donghoon Choi, Do Yun Lee, Byung-Chul Chang, Won-Heum Shim.   

Abstract

PURPOSE: To assess mid- to long-term clinical results of stent-graft repair in patients with type B aortic dissection.
METHODS: Retrospective analysis was done on 72 patients (47 men; mean age 55+/-12 years) who were diagnosed with chronic type B aortic dissection and underwent stent-graft repair from June 1994 to December 2007. Two types of stent-grafts were employed. Prior to 2000, a custom-designed stent-graft composed of self-expanding Z-type stainless steel stents covered with woven polytetrafluoroethylene material was used. Thereafter, a separate-type (modular) manufactured stent-graft was used, consisting of proximal and distal nitinol stents with an unsupported Dacron tube graft in between; the unsupported graft was stented after deployment.
RESULTS: Procedural success (completion of the stent-graft deployment at the target area without device failure) was obtained in 97% (70/72). The 2 failures were due to stent migration and tortuous anatomy, respectively. There were persistent type I endoleaks in 6 cases for a clinical success (entry tear exclusion) of 88% (64/72). There was no immediate postprocedural mortality or paraplegia. There was unintended partial left subclavian artery occlusion in 1 case, as well as postprocedural transient renal failure in 1 patient and 2 access-site pseudoaneurysms. Median follow-up was 43 months (range 5-97, mean 64.4+/-38.8) in 61 patients (3 patients lost to follow-up). Five patients died, 1 of probable aortic rupture in the setting of residual type I endoleak. Overall clinical success (no death, conversion, or endoleak) was achieved in 84% (47/56); of these, 35 (74%) showed complete resolution of the thoracic false lumen, while the other 12 (26%) had a decrease in false lumen diameter.
CONCLUSIONS: Intermediate to long-term results of stent-graft implantation in patients with chronic type B aortic dissection seem acceptable and may justify the use of this minimally invasive approach as first line therapy in these patients.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19281291     DOI: 10.1583/08-2563.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  6 in total

Review 1.  Strategies for managing aortoiliac occlusions: access, treatment and outcomes.

Authors:  Daniel G Clair; Jocelyn M Beach
Journal:  Expert Rev Cardiovasc Ther       Date:  2015-05

Review 2.  TEVAR: the solution to all aortic problems?

Authors:  I Akin; S Kische; T C Rehders; H Schneider; H Ince; C A Nienaber
Journal:  Herz       Date:  2011-09       Impact factor: 1.443

Review 3.  Systematic review of outcomes of combined proximal stent-grafting with distal bare stenting for management of aortic dissection.

Authors:  Ludovic Canaud; Elsa Madeleine Faure; Baris Ata Ozdemir; Pierre Alric; Matt Thompson
Journal:  Ann Cardiothorac Surg       Date:  2014-05

4.  Thoracic endovascular repair of chronic type B aortic dissection: a systematic review.

Authors:  Michael L Williams; Madeleine de Boer; Bridget Hwang; Bruce Wilson; John Brookes; Nicholas McNamara; David H Tian; Timothy Shiraev; Ourania Preventza
Journal:  Ann Cardiothorac Surg       Date:  2022-01

5.  [Stent graft of the thoracic aorta].

Authors:  C A Nienaber; I Akin; S Kische; H Ince; T Chatterjee
Journal:  Internist (Berl)       Date:  2013-05       Impact factor: 0.743

6.  Contemporary Management Strategies for Chronic Type B Aortic Dissections: A Systematic Review.

Authors:  Arnoud V Kamman; Hector W L de Beaufort; Guido H W van Bogerijen; Foeke J H Nauta; Robin H Heijmen; Frans L Moll; Joost A van Herwaarden; Santi Trimarchi
Journal:  PLoS One       Date:  2016-05-04       Impact factor: 3.240

  6 in total